Development and validation of eco-friendly micellar HPLC method for the simultaneous determination of hydrochlorothiazide and valsartan in bulk powder and pharmaceutical dosage forms

被引:10
作者
Ayad, Magda M. [1 ]
Hosny, Mervat M. [1 ]
Ibrahim, Adel Ehab [2 ]
El-Abassy, Omar M. [3 ]
Belal, Fathalla F. [4 ]
机构
[1] Zagazig Univ, Pharmaceut Analyt Chem Dept, Fac Pharm, Zagazig, Egypt
[2] Port Said Univ, Pharmaceut Analyt Chem Dept, Fac Pharm, Port Said, Egypt
[3] Egyptian Russian Univ, Pharmaceut Analyt Chem Dept, Fac Pharm, Badr City, Egypt
[4] Mansoura Univ, Pharmaceut Analyt Chem Dept, Fac Pharm, Mansoura, Egypt
关键词
Micellar liquid chromatography; Hydrochlorothiazide; Valsartan; Brij-35; RP-HPLC; PERFORMANCE; TABLETS; AMLODIPINE;
D O I
10.1007/s13738-020-01897-z
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ongoing greener in chromatography, new methodologies have to be developed using safer mobile phase composition and/or lower solvent consumption. The new methods should also consider the applicability in industrial facilities where selection criteria are based mainly on profit through cost and time. The drugs under study, valsartan (VAL) and hydrochlorothiazide (HCT), are co-formulated as tablet dosage form which is considered a widely consumed first-line treatment for hypertension. The use of the biodegradable non-ionic surfactant Brij-35 (0.1 M) in the aqueous phase increased the surface polarity of the bonded C-18 stationary phase by its polyoxyethylene chain. This change gave faster separation of the analytes in short analysis time, enabled the use of methanol instead of acetonitrile which is more environmentally safe and also decreased its ratio required to enhance elution to only 25%. Fast isocratic separation was achieved at flow 1 mL min(-1) where the retention times were 2.9 and 4.3 min for VAL and HCT, respectively, using UV detection at 254 nm. The method was validated according to ICH guidelines. High accuracy results were obtained at linearity range of 5-100 mu g mL(-1) for both drugs. LOD and LOQ were (1.01 and 3.05 mu g mL(-1)) for VAL and (1.01 and 3.09 mu g mL(-1)) for HCT, respectively. The method was successfully applied for determination of the drugs in their marketed dosage form. Since claiming greenness is not enough, the proposed method was compared favorably with published methods using the new assessment tool, GAPI index.
引用
收藏
页码:1725 / 1730
页数:6
相关论文
共 26 条
[1]   Simultaneous determination of valsartan and hydrochlorothiazide in tablets by high-performance liquid chromatography [J].
Carlucci, G ;
Di Carlo, V ;
Mazzeo, P .
ANALYTICAL LETTERS, 2000, 33 (12) :2491-2500
[2]  
El-Gizawy S.M., 2012, AM J ANAL CHEM, V03, P422
[3]   Spectrophotometric analysis of valsartan and hydrochlorothiazide [J].
Erk, N .
ANALYTICAL LETTERS, 2002, 35 (02) :283-302
[4]  
Gadepalli Shankar Ganesh, 2014, J Pharm Anal, V4, P399, DOI 10.1016/j.jpha.2013.12.003
[5]   Analytical Eco-Scale for assessing the greenness of analytical procedures [J].
Galuszka, Agnieszka ;
Konieczka, Piotr ;
Migaszewski, Zdzislaw M. ;
Namiesnik, Jacek .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 37 :61-72
[6]  
Greenberg M., 1999, Risk Assessment Division, P25
[7]  
Hafez HM, 2013, IRAN J PHARM RES, V12, P635
[8]   Simultaneous determination of the antihypertensives hydrochlorothiazide, losartan potassium, irbesartan and valsartan in bulk powders and pharmaceutical preparations by high performance liquid chromatography [J].
Hashem, Hisham ;
Ibrahim, Adel Ehab ;
Elhenawee, Magda .
MAIN GROUP CHEMISTRY, 2016, 15 (04) :335-346
[9]   Core-shell particles and monolithic columns; tools for simultaneous LC analysis of avanafil, sildenafil, apomorphine, trazodone, yohimbine, tramadol and dapoxetine in pharmaceutical dosage forms, counterfeit products and human plasma [J].
Ibrahim, Adel Ehab ;
Hashem, Hisham ;
Elhenawee, Magda ;
Saleh, Hanaa .
RSC ADVANCES, 2020, 10 (03) :1379-1387
[10]   Monitoring of impurity level of valsartan and hydrochlorothiazide employing an RP-HPLC gradient mode [J].
Ivanovic, Darko ;
Malenovic, Andelija ;
Jancic, Biljana ;
Medenica, Mirjana ;
Maskovic, Marija .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (19) :2879-2890