Validation of a clinical Shack-Hartmann aberrometer

被引:100
作者
Cheng, X [1 ]
Himebaugh, NL [1 ]
Kollbaum, PS [1 ]
Thibos, LN [1 ]
Bradley, A [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
关键词
wavefront aberrations; model eye; instrument calibration;
D O I
10.1097/00006324-200308000-00013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To validate the accuracy, tolerance, and repeatability of the complete ophthalmic analysis system aberrometer (COAS, Wavefront Sciences Inc.) with model eyes and normal human eyes. Method. Model eyes were constructed from six polymethyl methacrylate, single-surface lenses with known characteristics. Accuracy of second-order aberrations was verified by measuring defocus and astigmatism induced by series of spherical and cylindrical trial lenses. Accuracy of higher-order aberrations was evaluated by comparing ray-tracing predictions with measured spherical aberration and coma of the aspheric model eyes. Tolerance to axial and lateral misalignment was measured by controlled displacements of the model eye relative to the aberrometer. Repeatability was tested on the same model eyes with repeated measurements taken within 1 s or within half an hour with realignment between each trial. Analyses were based on a 5-mm pupil diameter. Results. Defocus and astigmatism were accurately measured within the working range of the instrument automatic focus adjustment (e.g., measured defocus was within +/-0.25 diopters over a -6.50 to +3.00 D range of refractive error). Accuracy of spherical aberration and coma agreed closely with theoretical predictions (e.g., for all six aspheric models, the mean absolute difference between predicted and measured Z(4)(0) was 0.007 mum). Axial displacements over the range +/-2.5 mm had little effect on measurements for myopic and emmetropic model eyes. Also, lateral displacements over the range +/-1.5 mm did not produce significant coma. The standard deviations of repeated measurements of higher-order root mean square on model eyes were < 1 % of the mean with repeated measures within 1 s and 10% of the mean for five individual measurements with realignment in between each. Tolerance to small lateral displacements was also observed for human eyes. Conclusion. The complete ophthalmic analysis system aberrometer can measure second-, third-, and fourth-order aberrations accurately and repeatedly on model eyes.
引用
收藏
页码:587 / 595
页数:9
相关论文
共 31 条
[1]   The repeatability of automated and clinician refraction [J].
Bullimore, MA ;
Fusaro, RE ;
Adams, CW .
OPTOMETRY AND VISION SCIENCE, 1998, 75 (08) :617-622
[2]  
Castejón-Mochón JF, 2002, VISION RES, V42, P1611, DOI 10.1016/S0042-6989(02)00085-8
[3]   Relationship between refractive error and monochromatic aberrations of the eye [J].
Cheng, X ;
Bradley, A ;
Hong, X ;
Thibos, LN .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (01) :43-49
[4]  
CHENG X, 2003, IN PRESS INVEST OPHT
[5]  
Goss D A, 1996, J Am Optom Assoc, V67, P619
[6]   Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes [J].
Guirao, A ;
Porter, J ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01) :1-9
[7]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[8]   Comparison of monochromatic ocular aberrations measured with an objective cross-cylinder aberroscope and a Shack-Hartmann aberrometer [J].
Hong, X ;
Thibos, LN ;
Bradley, A ;
Woods, RL ;
Applegate, RA .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (01) :15-25
[9]   On-eye evaluation of optical performance of rigid and soft contact lenses [J].
Hong, X ;
Himebaugh, N ;
Thibos, LN .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (12) :872-880
[10]  
Hong X, 2000, J REFRACT SURG, V16, pS647