Regeneration of poly-L-lysine modified carbon electrodes in the accumulation and cathodic stripping voltammetric determination of the cromoglycate anion

被引:35
作者
Pereira, FC
Fogg, AG
Zanoni, MVB
机构
[1] Univ Estadual Paulista, Inst Quim, Dept Quim Analt, BR-14801970 Araraquara, SP, Brazil
[2] Univ Luton, Luton Inst, Luton LU1 5DU, Beds, England
[3] Loughborough Univ Technol, Loughborough LE11 3TU, Leics, England
基金
巴西圣保罗研究基金会;
关键词
poly-L-lysine; sodium cromoglycate; modified electrodes; electroanalysis;
D O I
10.1016/S0039-9140(03)00181-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cromoglycate is accumulated on a poly-L-lysine (PLL) modified carbon electrode best from pH 4 solution, where it is anionic and the PLL is cationic, and at which pH the cromoglycate gives a good reduction peak at -0.82 V. The PLL film can be regenerated readily by washing the electrode with 3 M sodium hydroxide solution, in which the PLL is deprotonated. Regeneration of the film is not required as frequently when larger amounts of PLL are incorporated into it. This allows standard addition procedures to be carried out without regenerating the electrode. Linear calibration graphs have been obtained typically in the range 0.1 - 1.5 mug ml(-1). Detection limits have been calculated to be 10 ng ml(-1). The standard addition method has been applied satisfactorily to diluted urine solutions. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1023 / 1032
页数:10
相关论文
共 31 条
[1]   NEW MODEL FOR THE INTERIOR OF POLY-ELECTROLYTE COATINGS ON ELECTRODE SURFACES - MECHANISMS OF CHARGE TRANSPORT THROUGH PROTONATED POLY(L-LYSINE) FILMS CONTAINING FE-III(EDTA)- AND FE-II(EDTA)2- AS COUNTERIONS [J].
ANSON, FC ;
SAVEANT, JM ;
SHIGEHARA, K .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1983, 105 (05) :1096-1106
[2]   DIFFUSIONAL PATHWAYS FOR MULTIPLY CHARGED IONS INCORPORATED IN POLY-ELECTROLYTE COATINGS ON GRAPHITE-ELECTRODES - CO(C2O4)3(3-) IN COATINGS OF PROTONATED POLYLYSINE [J].
ANSON, FC ;
OHSAKA, T ;
SAVEANT, JM .
JOURNAL OF PHYSICAL CHEMISTRY, 1983, 87 (04) :640-647
[3]   Development and validation of an ion-pair liquid chromatographic method for the quantitation of sodium cromoglycate in urine following inhalation [J].
Aswania, OA ;
Corlett, SA ;
Chrystyn, H .
JOURNAL OF CHROMATOGRAPHY B, 1997, 690 (1-2) :373-378
[4]   ION-EXCHANGE PROPERTIES OF POLY(L-LYSINE) COATINGS ON PYROLYTIC-GRAPHITE ELECTRODES [J].
BIANCO, P ;
HALADJIAN, J ;
GIANNANDREADEROCLES, S .
ELECTROANALYSIS, 1994, 6 (01) :67-74
[5]   RADIOIMMUNOASSAY OF SODIUM CROMOGLYCATE IN HUMAN-PLASMA [J].
BROWN, K ;
GARDNER, JJ ;
LOCKLEY, WJS ;
PRESTON, JR ;
WILKINSON, DJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1983, 20 (JAN) :31-36
[6]   Electrochemical studies of nitroprusside in the presence of copper(II):: formation of Cu(I) reduced nitroprusside species [J].
Carapuça, HM ;
Filipe, OMS ;
Simao, JEJ ;
Fogg, AG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 480 (1-2) :84-93
[7]   RESPIRABLE FORM OF CRYSTALS OF CROMOGLYCIC ACID [J].
CHAN, HK ;
GONDA, I .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1989, 78 (02) :176-180
[8]  
DUHAIME RM, 1994, J AOAC INT, V77, P1439
[9]   Cathodic stripping voltammetric determination of ceftazidime with reactive accumulation at a poly-L-lysine modified hanging mercury drop electrode [J].
Ferreira, VS ;
Zanoni, MVB ;
Fogg, AG .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :159-166
[10]   DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF DISODIUM-CROMOGLYCATE IN URINE [J].
FOGG, AG ;
FAYAD, N .
ANALYTICA CHIMICA ACTA, 1978, 102 (DEC) :205-210