Surgical never events and contributing human factors

被引:77
作者
Thiels, Cornelius A. [1 ]
Lal, Tarun Mohan [2 ]
Nienow, Joseph M. [3 ]
Pasupathy, Kalyan S. [2 ]
Blocker, Renaldo C. [2 ]
Aho, Johnathon M. [1 ]
Morgenthaler, Timothy I. [4 ]
Cima, Robert R. [1 ]
Hallbeck, Susan [2 ]
Bingener, Juliane [1 ]
机构
[1] Mayo Clin, Dept Surg, Rochester, MN 55905 USA
[2] Mayo Clin, Ctr Sci Hlth Care Delivery, Rochester, MN 55905 USA
[3] Mayo Clin, Qual Management Serv, Rochester, MN 55905 USA
[4] Mayo Clin, Pulm & Crit Care Med, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
OPERATING-ROOM; HUMAN ERROR; OCCURRENCES; SAFETY; CARE;
D O I
10.1016/j.surg.2015.03.053
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction. We report the first prospective analysis of human factors elements contributing to invasive procedural never events by using a validated Human Factors Analysis and Classification System (HFACS). Methods. From August 2009 to August 2014, operative and invasive procedural "Never Events" (retained foreign object, wrong site/side procedure, wrong implant, wrong procedure) underwent systematic causation analysis promptly after the event. Contributing human factors were categorized using the 4 levels of error causation described by Reason and 161 HFACS subcategories (nano-codes). Results. During the study, approximately 1.5 million procedures were performed, during which 69 never events were identified. A total of 628 contributing human factors nano-codes were identified. Action-based errors (n = 260) and preconditions to actions (n = 296) accounted for the majority of the nano-codes across all 4 types of events, with individual cognitive factors contributing one half of the nano-codes. The most common action nano-codes were confirmation bias (n = 36) and failed to understand (n = 36). The most common precondition nano-codes were channeled attention on a single issue (n 33) and inadequate communication (n = 30). Conclusion. Targeting quality and interventions in system improvement addressing cognitive factors and team resource management as well as perceptual biases may decrease errors and further improve patient safety. These results delineate targets to further decrease never events from our health care system.
引用
收藏
页码:515 / 521
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1999, LIVING HIGH RISK TEC
[2]  
[Anonymous], 1999, To err is human: building a safer health system
[3]  
[Anonymous], 2014, AMA NEWS
[4]  
[Anonymous], 2011, SER REP EV HEALTHC 2
[5]   Using a Data-Matrix-Coded Sponge Counting System Across a Surgical Practice: Impact After 18 Months [J].
Cima, Robert R. ;
Kollengode, Anantha ;
Clark, James ;
Pool, Sarah ;
Weisbrod, Cheryl ;
Amstutz, Gwendolyn J. ;
Deschamps, Claude .
JOINT COMMISSION JOURNAL ON QUALITY AND PATIENT SAFETY, 2011, 37 (02) :51-+
[6]   Nature of human error - Implications for surgical practice [J].
Cuschieri, Alfred .
ANNALS OF SURGERY, 2006, 244 (05) :642-648
[7]   The Human Factors Analysis Classification System (HFACS) Applied to Health Care [J].
Diller, Thomas ;
Helmrich, George ;
Dunning, Sharon ;
Cox, Stephanie ;
Buchanan, April ;
Shappell, Scott .
AMERICAN JOURNAL OF MEDICAL QUALITY, 2014, 29 (03) :181-190
[8]   Application of the human factors analysis and classification system methodology to the cardiovascular surgery operating room [J].
ElBardissi, Andrew W. ;
Wiegmann, Douglas A. ;
Dearani, Joseph A. ;
Daly, Richard C. ;
Sundt, Thoralf M., III .
ANNALS OF THORACIC SURGERY, 2007, 83 (04) :1412-1419
[9]  
Hallbeck MS, 2008, STUD HEALTH TECHNOL, V132, P147
[10]   Retained surgical sponges, needles and instruments [J].
Hariharan, D. ;
Lobo, D. N. .