Quantitative and noninvasive assessment of chronic liver diseases using two-dimensional shear wave elastography

被引:42
作者
Xie, Li-Ting [1 ]
Yan, Chun-Hong [1 ]
Zhao, Qi-Yu [1 ]
He, Meng-Na [1 ]
Jiang, Tian-An [1 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 1, Dept Ultrasound, Qingchun Rd 79, Hangzhou 310003, Zhejiang, Peoples R China
关键词
Elastography; Shear wave; Chronic liver disease; Liver fibrosis; NONALCOHOLIC FATTY LIVER; CHRONIC HEPATITIS-B; IMPULSE IMAGING ARFI; 1 BASIC PRINCIPLES; ULTRASOUND ELASTOGRAPHY; CLINICAL-USE; DIAGNOSTIC-ACCURACY; TRANSIENT ELASTOGRAPHY; EFSUMB GUIDELINES; INTRAOBSERVER-REPRODUCIBILITY;
D O I
10.3748/wjg.v24.i9.957
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Two-dimensional shear wave elastography (2D-SWE) is a rapid, simple and novel noninvasive method that has been proposed for assessing hepatic fibrosis in patients with chronic liver diseases (CLDs) based on measurements of liver stiffness. 2D-SWE can be performed easily at the bedside or in an outpatient clinic and yields immediate results with good reproducibility. Furthermore, 2D-SWE was an efficient method for evaluating liver fibrosis in small to moderately sized clinical trials. However, the quality criteria for the staging of liver fibrosis are not yet well defined. Liver fibrosis is the main pathological basis of liver stiffness and a key step in the progression from CLD to cirrhosis; thus, the management of CLD largely depends on the extent and progression of liver fibrosis. 2D-SWE appears to be an excellent tool for the early detection of cirrhosis and may have prognostic value in this context. Because 2D-SWE has high patient acceptance, it could be useful for monitoring fibrosis progression and regression in individual cases. However, multicenter data are needed to support its use. This study reviews the current status and future perspectives of 2D-SWE for assessments of liver fibrosis and discusses the technical advantages and limitations that impact its effective and rational clinical use.
引用
收藏
页码:957 / 970
页数:14
相关论文
共 87 条
[11]   Non-invasive assessment of liver fibrosis with impulse elastography: Comparison of Supersonic Shear Imaging with ARFI and FibroScan [J].
Cassinotto, Christophe ;
Lapuyade, Bruno ;
Mouries, Amaury ;
Hiriart, Jean-Baptiste ;
Vergniol, Julien ;
Gaye, Delphine ;
Castain, Claire ;
Le Bail, Brigitte ;
Chermak, Faiza ;
Foucher, Juliette ;
Laurent, Francois ;
Montaudon, Michel ;
De Ledinghen, Victor .
JOURNAL OF HEPATOLOGY, 2014, 61 (03) :550-557
[12]   Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations [J].
Castera, Laurent ;
Foucher, Juliette ;
Bernard, Pierre-Henri ;
Carvalho, Francoise ;
Allaix, Daniele ;
Merrouche, Wassil ;
Couzigou, Patrice ;
de Ledinghen, Victor .
HEPATOLOGY, 2010, 51 (03) :828-835
[13]   Ultrasound elastographic techniques in focal liver lesions [J].
Conti, Clara Benedetta ;
Cavalcoli, Federica ;
Fraquelli, Mirella ;
Conte, Dario ;
Massironi, Sara .
WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (09) :2647-2656
[14]   EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 2: Clinical Applications [J].
Cosgrove, D. ;
Piscaglia, F. ;
Bamber, J. ;
Bojunga, J. ;
Correas, J. -M. ;
Gilja, O. H. ;
Klauser, A. S. ;
Sporea, I. ;
Calliada, F. ;
Cantisani, V. ;
D'Onofrio, M. ;
Drakonaki, E. E. ;
Fink, M. ;
Friedrich-Rust, M. ;
Fromageau, J. ;
Havre, R. F. ;
Jenssen, C. ;
Ohlinger, R. ;
Saftoiu, A. ;
Schaefer, F. ;
Dietrich, C. F. .
ULTRASCHALL IN DER MEDIZIN, 2013, 34 (03) :238-253
[15]  
Dietrich CF, 2017, ULTRASCHALL MED, V38, pE52, DOI [10.1055/a-0641-0076, 10.1055/s-0043-103952]
[16]   EASL 2017 Clinical Practice Guidelines on the management of hepatitis B virus infection [J].
Lampertico P. ;
Agarwal K. ;
Berg T. ;
Buti M. ;
Janssen H.L.A. ;
Papatheodoridis G. ;
Zoulim F. ;
Tacke F. .
JOURNAL OF HEPATOLOGY, 2017, 67 (02) :370-398
[17]   Diagnostic Accuracy of SuperSonic Shear Imaging for Staging of Liver Fibrosis A Meta-analysis [J].
Feng, Jin-Chun ;
Li, Jun ;
Wu, Xiang-Wei ;
Peng, Xin-Yu .
JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (02) :329-339
[18]   WFUMB GUIDELINES AND RECOMMENDATIONS FOR CLINICAL USE OF ULTRASOUND ELASTOGRAPHY: PART 3: LIVER [J].
Ferraioli, Giovanna ;
Filice, Carlo ;
Castera, Laurent ;
Choi, Byung Ihn ;
Sporea, Ioan ;
Wilson, Stephanie R. ;
Cosgrove, David ;
Dietrich, Christoph F. ;
Amy, Dominique ;
Bamber, Jeffrey C. ;
Barr, Richard ;
Chou, Yi-Hong ;
Ding, Hong ;
Farrokh, Andre ;
Friedrich-Rust, Mireen ;
Hall, Timothy J. ;
Nakashima, Kazutaka ;
Nightingale, Kathryn R. ;
Palmeri, Mark L. ;
Schafer, Fritz ;
Shiina, Tsuyoshi ;
Suzuki, Shinichi ;
Kudo, Masatoshi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) :1161-1179
[19]   Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study [J].
Ferraioli, Giovanna ;
Tinelli, Carmine ;
Dal Bello, Barbara ;
Zicchetti, Mabel ;
Filice, Gaetano ;
Filice, Carlo .
HEPATOLOGY, 2012, 56 (06) :2125-2133
[20]   Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity [J].
Ferraioli, Giovanna ;
Tinelli, Carmine ;
Zicchetti, Mabel ;
Above, Elisabetta ;
Poma, Gianluigi ;
Di Gregorio, Marta ;
Filice, Carlo .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) :3102-3106