Can parameters of the helical axis be measured reliably during active cervical movements?

被引:14
作者
Barbero, Marco [1 ]
Falla, Deborah [2 ]
Clijsen, Ron [3 ]
Ghirlanda, Filippo [1 ]
Schneebeli, Alessandro [1 ]
Ernst, Markus J. [4 ]
Cescon, Corrado [1 ]
机构
[1] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, 2rLab, Manno, Switzerland
[2] Univ Birmingham, Coll Life & Environm Sci, Sch Sport Exercise & Rehabil Sci, Ctr Precis Rehabil Spinal Pain CPR Spine, Birmingham, W Midlands, England
[3] Univ Appl Sci & Arts Southern Switzerland, Dept Business Econ Hlth & Social Care, Landquart, Switzerland
[4] Zurich Univ Appl Sci, Sch Hlth Profess, Technikumstr 71, CH-8401 Winterthur, Switzerland
关键词
Helical axis; Cervical kinematics; Reliability; WHIPLASH-ASSOCIATED DISORDERS; NONSPECIFIC NECK PAIN; MOTION; KINEMATICS; SPINE; RANGE; RELIABILITY; ROTATION; HEAD;
D O I
10.1016/j.math.2016.10.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Convex hull area (CHA) and mean angle (MA) have been proposed to describe the behaviour of the helical axis during joint kinematics. This study investigates the intra-and inter-session reliability of CHA and MA during active movements of the cervical spine. Twenty-seven healthy volunteers (19 women) aged 23 +/- 2.8 years participated. Each volunteer was tested on two sessions. All participants were instructed to perform the following active movements of the cervical spine: rotation, flexion/extension and lateral bending, each performed to full range and repeated ten consecutive times. Cervical movements were registered with an electromagnetic tracking system. For each participant, each movement and each session, range of motion (ROM), CHA and MA were extracted. ROM showed high intra-and inter-session reliability during all cervical spine movements using this method. Overall, the intra-and inter-session reliability of the helical axis parameters varied depending on the movement direction and ranged from fair to almost perfect. The intra-and inter-session reliability of CHA and MA were almost perfect during rotation whereas the intra-and inter-session reliability of CHA was substantial during lateral bending and intra-and inter-session reliability of MA ranged from fair to substantial during flexion/extension and lateral bending. This is the first study to evaluate the reliability of helical axis measures during active movements of the cervical spine. The results show that CHA and MA are promising descriptors of cervical kinematics which could be applied in future studies to evaluate neck function in patients with cervical spine disorders. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 19 条
[1]   Validity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device [J].
Audette, Isabel ;
Dumas, Jean-Pierre ;
Cote, Julie N. ;
De Serres, Sophie J. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2010, 40 (05) :318-323
[2]  
Cescon C., 2015, ARCH PHYSIOTHER, V5, P1
[3]   Methodological analysis of finite helical axis behavior in cervical kinematics [J].
Cescon, Corrado ;
Cattrysse, Erik ;
Barbero, Marco .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2014, 24 (05) :628-635
[4]   Animation of in vitro biomechanical tests [J].
Cripton, PA ;
Sati, M ;
Orr, TE ;
Bourquin, Y ;
Dumas, GA ;
Nolte, LP .
JOURNAL OF BIOMECHANICS, 2001, 34 (08) :1091-1096
[5]   CLINICAL VALIDATION OF FUNCTIONAL FLEXION EXTENSION RADIOGRAPHS OF THE CERVICAL-SPINE [J].
DVORAK, J ;
PANJABI, MM ;
GROB, D ;
NOVOTNY, JE ;
ANTINNES, JA .
SPINE, 1993, 18 (01) :120-127
[6]   Intrarater Reliability of CROM Measurement of Cervical Spine Active Range of Motion in Persons With and Without Neck Pain [J].
Fletcher, James P. ;
Bandy, William D. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (10) :640-645
[7]   The shifting of the torsion axis of the foot during the stance phase of lateral cutting movements [J].
Graf, Eveline S. ;
Stefanyshyn, Darren J. .
JOURNAL OF BIOMECHANICS, 2012, 45 (15) :2680-2683
[8]   A new approach to measure functional stability of the knee based on changes in knee axis orientation [J].
Grip, H. ;
Hager, C. .
JOURNAL OF BIOMECHANICS, 2013, 46 (05) :855-862
[9]   Cervical helical axis characteristics and its center of rotation during active head and upper arm movements-comparisons of whiplash-associated disorders, non-specific neck pain and asymptomatic individuals [J].
Grip, Helena ;
Sundelin, Gunnevi ;
Gerdle, Bjoern ;
Karlsson, J. Stefan .
JOURNAL OF BIOMECHANICS, 2008, 41 (13) :2799-2805
[10]   Variations in the axis of motion during head repositioning - A comparison of subjects with whiplash-associated disorders or non-specific neck pain and healthy controls [J].
Grip, Helena ;
Sundelin, Gunnevi ;
Gerdle, Bjoern ;
Karlsson, J. Stefan .
CLINICAL BIOMECHANICS, 2007, 22 (08) :865-873