Measurement of activated clotting time in children -: comparison of the Celite i-STAT® ACT with the Medtronic ACT® II

被引:9
作者
Hug, MI
Di Bernardo, S
Berger, F
Bauersfeld, U
Weiss, M
机构
[1] Univ Zurich, Childrens Hosp, Dept Intens Care & Neonatol, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Childrens Hosp, Dept Cardiol, CH-8032 Zurich, Switzerland
[3] Univ Zurich, Childrens Hosp, Dept Anaesthesia, CH-8032 Zurich, Switzerland
关键词
ACT; activated clotting time; coagulation testing; heparin; heparinization; point-of-care testing;
D O I
10.1111/j.1399-6576.2004.00296.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: To evaluate a recently introduced blood-saving method for the measurement of activated clotting time (ACT), the Celite i-STAT((R)) ACT, by comparing the values obtained with those from the widely used Medtronic ACT((R)) II device. Methods: In a prospective clinical study, we compared ACT values from the i-STAT((R)) device with the Medtronic ACT((R)) II device in 60 paediatric, interventional, cardiac catheterization procedures necessitating prophylactic heparinization. Blood samples were pair-analyzed using two i-STAT((R)) analyzers and one Medtronic ACT((R)) II device with double-tube-cartridges before and after heparinization. Data were compared using Bland-Altman bias analysis, Student's t-test and simple regression analysis. Results: Bias and precision between the Medtronic ACT((R)) II and the i-STAT((R)) ACT values was -5.4 +/- 26.3. The i-STAT((R)) and Medtronic ACT((R)) II values were similar before heparinization (P = 0.22), but i-STAT((R)) ACT values became significantly longer than Medtronic ACT((R)) II values after heparinization (P = 0.021). The increase of ACT after heparinization was greater (median 86.3; range 40-187 s) in the i-STAT((R)) analyzer than in the Medtronic ACT((R)) II analyzer (median 73.0; range 19-235.5 s). Increase in ACT values was inversely affected by intraoperative haemoglobin concentration in the Medtronic ACT((R)) II analyzer (P = 0.001) but not in the i-STAT((R)) analyzer. Conclusion: Activated clotting times obtained from the Celite i-STAT((R)) ACT and the Medtronic ACT((R)) II demonstrated poor agreement. The technical principles are quite different and the two methods showed diverse susceptibility to intraoperative haemoglobin concentration. Users have to be aware of technique-specific ACT target ranges and their confounders, which need to be provided by the manufacturers.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 17 条
[1]   COMPARISON OF HEMOCHRON AND HEMOTEC ACTIVATED COAGULATION TIME TARGET VALUES DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
AVENDANO, A ;
FERGUSON, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (04) :907-910
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   THE USE OF ACTIVATED CLOTTING TIMES TO MONITOR HEPARIN-THERAPY DURING AND AFTER INTERVENTIONAL PROCEDURES [J].
BOWERS, J ;
FERGUSON, JJ .
CLINICAL CARDIOLOGY, 1994, 17 (07) :357-361
[4]  
FERGUSON JJ, 1992, TEX HEART I J, V19, P1
[5]   Evaluation of i-STAT portable clinical analyzer in a hemodialysis unit [J].
Gault, MH ;
Harding, CE .
CLINICAL BIOCHEMISTRY, 1996, 29 (02) :117-124
[6]   RATIONAL APPROACH TO USE OF HEPARIN DURING CARDIAC-CATHETERIZATION IN CHILDREN [J].
GRADY, RM ;
EISENBERG, PR ;
BRIDGES, ND .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (03) :725-729
[7]   ACTIVATED COAGULATION TIME OF WHOLE BLOOD [J].
HATTERSLEY, PG .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1966, 196 (05) :436-+
[8]   Near-patient testing - point-of-care or point of costs and convenience? [J].
Jahn, UR ;
Van Aken, H .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (04) :425-427
[9]   The plasma supplemented modified activated clotting time for monitoring of heparinization during cardiopulmonary bypass: A pilot investigation [J].
Koster, A ;
Despotis, G ;
Gruendel, M ;
Fischer, T ;
Praus, M ;
Kuppe, H ;
Levy, JH .
ANESTHESIA AND ANALGESIA, 2002, 95 (01) :26-30
[10]   Phlebotomy overdraw in the neonatal intensive care nursery [J].
Lin, JC ;
Strauss, RG ;
Kulhavy, JC ;
Johnson, KJ ;
Zimmerman, MB ;
Cress, GA ;
Connolly, NW ;
Widness, JA .
PEDIATRICS, 2000, 106 (02) :art. no.-e19