Long-term outcomes after aortic valve replacement using a 19-mm bioprosthesis

被引:3
作者
Okamura, Homare [1 ]
Kusadokoro, Sho [1 ]
Mieno, Makiko [2 ]
Kimura, Naoyuki [1 ]
Yamaguchi, Atsushi [1 ]
机构
[1] Jichi Med Univ, Saitama Med Ctr, Dept Cardiovasc Surg, Saitama, Japan
[2] Jichi Med Univ, Ctr Informat, Dept Med Informat, Shimotsuke, Tochigi, Japan
关键词
Aortic valve replacement; 19-mm bioprosthesis; Prosthesis-patient mismatch; PROSTHESIS-PATIENT MISMATCH; LEFT-VENTRICULAR MASS; HIGH-RISK PATIENTS; MORTALITY; IMPACT; TRANSCATHETER; HEMODYNAMICS; POSITION; STENOSIS;
D O I
10.1093/ejcts/ezab379
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Transcatheter aortic valve replacement is known to be associated with improved haemodynamics in patients with aortic stenosis and a small aortic annulus. However, limited benchmark data are available regarding the long-term outcomes in patients treated with surgical aortic valve replacement (SAVR). We investigated the long-term outcomes of SAVR using a 19-mm bioprosthesis. METHODS This study included consecutive patients who underwent SAVR using a 19-mm bioprosthesis at our hospital between 2008 and 2012. RESULTS In a total of 132 patients, moderate and severe prosthesis-patient mismatch occurred in 36 (27.3%) and 7 patients (5.3%), respectively. The median follow-up period was 7.7 years. The overall 5- and 10-year survival rates were 79.4% and 52.9%, respectively. The 5- and 10-year freedom from major adverse valve-related events rates were 89.6% and 74.2%, respectively. Neither moderate nor severe prosthesis-patient mismatch was associated with late mortality, major adverse valve-related events or heart failure. Follow-up echocardiographic data were obtained at a median interval of 4.8 years in 80% of patients who survived >= 6 months postoperatively. Follow-up echocardiographic data showed a significantly increased left ventricular ejection fraction, decreased mean transvalvular/transprosthetic pressure gradients and a decreased mean left ventricular mass. At follow-up, we observed moderate or severe haemodynamic structural valve deterioration in 17 patients; however, structural valve deterioration did not affect late survival or freedom from major adverse valve-related events rates, or heart failure. CONCLUSIONS SAVR using the 19-mm bioprosthesis was associated with satisfactory long-term clinical and haemodynamic outcomes.
引用
收藏
页码:625 / 634
页数:10
相关论文
共 26 条
[1]  
Akins CW, 2008, ANN THORAC SURG, V85, P1490, DOI [10.1016/j.athoracsur.2007.12.082, 10.1016/j.ejcts.2007.12.055]
[2]   Left Ventricular Mass and Hypertrophy by Echocardiography and Cardiac Magnetic Resonance: The Multi-Ethnic Study of Atherosclerosis [J].
Armstrong, Anderson C. ;
Gjesdal, Ola ;
Almeida, Andre ;
Nacif, Marcelo ;
Wu, Colin ;
Bluemke, David A. ;
Brumback, Lyndia ;
Lima, Joao A. C. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (01) :12-20
[3]   Surgical aortic valve replacement and patient-prosthesis mismatch: a meta-analysis of 108 182 patients [J].
Barros de Oliveira Sa, Michel Pompeu ;
Barros de Carvalho, Martinha Millianny ;
Sobral Filho, Dario Celestino ;
Pereira Cavalcanti, Luiz Rafael ;
Rayol, Sergio da Costa ;
Silva Diniz, Roberto Gouvea ;
Menezes, Alexandre Motta ;
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Lima, Ricardo Carvalho .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (01) :44-54
[4]   Trifecta Versus Perimount Magna Ease Aortic Valve Prostheses [J].
Biancari, Fausto ;
Valtola, Antti ;
Juvonen, Tatu ;
Husso, Annastiina ;
Dahlbacka, Sebastian ;
Laakso, Teemu ;
Jalava, Maina P. ;
Tauriainen, Tuomas ;
Ahvenvaara, Tuomas ;
Kinnunen, Eeva-Maija ;
Niemela, Matti ;
Makikallio, Timo ;
Eskola, Markku ;
Virtanen, Marko P. O. ;
Maaranen, Pasi ;
Rosato, Stefano ;
Anttila, Vesa ;
Vento, Antti ;
Airaksinen, Juhani ;
Raivio, Peter .
ANNALS OF THORACIC SURGERY, 2020, 110 (03) :879-888
[5]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[6]   Very Long-Term Outcomes of the Carpentier-Edwards Perimount Valve in Aortic Position [J].
Bourguignon, Thierry ;
Bouquiaux-Stablo, Anne-Lorraine ;
Candolfi, Pascal ;
Mirza, Alain ;
Loardi, Claudia ;
May, Marc-Antoine ;
El-Khoury, Rym ;
Marchand, Michel ;
Aupart, Michel .
ANNALS OF THORACIC SURGERY, 2015, 99 (03) :831-837
[7]   Standardized definitions of structural deterioration and valve failure in assessing long-termdurability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) endorsed by the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) [J].
Capodanno, Davide ;
Petronio, Anna S. ;
Prendergast, Bernard ;
Eltchaninoff, Helene ;
Vahanian, Alec ;
Modine, Thomas ;
Lancellotti, Patrizio ;
Sondergaard, Lars ;
Ludman, Peter F. ;
Tamburino, Corrado ;
Piazza, Nicolo ;
Hancock, Jane ;
Mehilli, Julinda ;
Byrne, Robert A. ;
Baumbach, Andreas ;
Kappetein, Arie Pieter ;
Windecker, Stephan ;
Bax, Jeroen ;
Haude, Michael .
EUROPEAN HEART JOURNAL, 2017, 38 (45) :3382-+
[8]   Indexed effective orifice area is a significant predictor of higher mid- and long-term mortality rates following aortic valve replacement in patients with prosthesis-patient mismatch [J].
Chen, Jian ;
Lin, Yiyun ;
Kang, Bo ;
Wang, Zhinong .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (02) :234-240
[9]   Left Ventricular Mass Quantification by Two-Dimensional Echocardiography in a Pediatric Population: Correlation with Cardiac Magnetic Resonance Imaging [J].
Chu, Bradford J. ;
Lee, Timothy ;
Gilbreth, John G. ;
Nielsen, James C. ;
Ludomirsky, Achiau ;
Tretter, Justin T. ;
Bhatla, Puneet .
PEDIATRIC CARDIOLOGY, 2019, 40 (02) :412-420
[10]  
Dalmau Maria Jose, 2006, Interact Cardiovasc Thorac Surg, V5, P263, DOI 10.1510/icvts.2005.120352