Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups

被引:64
作者
Wu, Feng [1 ,2 ]
Huang, Ting [1 ]
Hu, Yangjian [2 ]
Yang, Xin [2 ]
Ouyang, Yuejun [2 ]
Xie, Qingji [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Key Lab Chem Biol & Tradit Chinese Med Res, Minist Educ, Changsha 410081, Hunan, Peoples R China
[2] Huaihua Coll, Chem & Mat Engn Dept, Huaihua 418008, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemical sensor; Anodization; Cyclic voltammetry; Differential pulse voltammetry; Ascorbic acid; Dopamine; Uric acid; Urine analysis; ELECTROCHEMICAL DETERMINATION; PASTE ELECTRODE; IONIC LIQUIDS; LAYER; SENSOR; NANOPARTICLES; SURFACES; REDUCTION; NANOTUBES; BEHAVIOR;
D O I
10.1007/s00604-016-1895-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCE(ox)). Next, an imidazolium alkoxysilane (ImAS) is covalently tethered to the surface of the GCE(ox) via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and pi-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCE(ox) by CV yields electroreduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at -50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 mu M for AA, from 20 to 490 mu M for UA, and from 0.1 to 5 mu M and from 5 mu M to 200 mu M (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 mu M, 5 mu M and 0.03 mu M. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine.
引用
收藏
页码:2539 / 2546
页数:8
相关论文
共 34 条
[1]   Electrochemical behavior of dopamine and ascorbic acid at dendritic Au rod surfaces: Selective detection of dopamine in the presence of high concentration of ascorbic acid [J].
Ahn, Miri ;
Kim, Jongwon .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 683 :75-79
[2]   Ascorbic acid: much more than just an antioxidant [J].
Arrigoni, O ;
De Tullio, MC .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2002, 1569 (1-3) :1-9
[3]   A voltammetric sensor based on graphene-modified electrode for the determination of trace amounts of L-dopa in mouse brain extract and pharmaceuticals [J].
Arvand, Majid ;
Ghodsi, Navid .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (03) :775-784
[4]   Electrochemical determination of ascorbic acid, dopamine and uric acid based on an exfoliated graphite paper electrode: A high performance flexible sensor [J].
Cai, Weihua ;
Lai, Ting ;
Du, Haijun ;
Ye, Jianshan .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 :492-500
[5]   Validation of chromatographic methods in biomedical analysis - Viewpoint and discussion [J].
Causon, R .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :175-180
[6]   Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application [J].
Chen, Liuyun ;
Tang, Yanhong ;
Wang, Ke ;
Liu, Chengbin ;
Luo, Shenglian .
ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (02) :133-137
[7]   Serum uric acid and risk for cardiovascular disease and death: The Framingham Heart Study [J].
Culleton, BF ;
Larson, MG ;
Kannel, WB ;
Levy, D .
ANNALS OF INTERNAL MEDICINE, 1999, 131 (01) :7-+
[8]   Immobilization of imidazolium ionic liquids on hydrotalcites using silane linkers: retardation of memory effect [J].
Finn, M. ;
An, N. ;
Voutchkova-Kostal, A. .
RSC ADVANCES, 2015, 5 (17) :13016-13020
[9]   Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid in the presence of sodium dodecyl sulphate using a multi-walled carbon nanotube modified carbon paste electrode [J].
Ghoreishi, Sayed Mehdi ;
Behpour, Mohsen ;
Mousavi, Samira ;
Khoobi, Asma ;
Ghoreishi, Farzaneh Sadat .
RSC ADVANCES, 2014, 4 (72) :37979-37984
[10]   HPLC DETECTION OF DOPAMINE AND NORADRENALINE IN THE COCHLEA OF ADULT AND DEVELOPING RATS [J].
GILLOYZAGA, P ;
PARESHERBUTE, N .
DEVELOPMENTAL BRAIN RESEARCH, 1989, 48 (01) :157-160