Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions

被引:0
|
作者
Tseng, GY
Thng, CH
Wong, EH
Tan, AGS
Suman, P
Quek, ST
Ho, JTS
Khoo, JKB
Ooi, LLPJ
Chow, PKH
Chung, YFA
Teh, CSC
机构
[1] Singapore Gen Hosp, Dept Diagnost Radiol, Singapore 169608, Singapore
[2] Singapore Gen Hosp, Dept Gen Surg, Singapore, Singapore
关键词
comparative studies; liver neoplasm; pulse sequences; receiver operating characteristic curve;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: We compare the breath-hold fast recovery fast spin echo (BHFRFSE) T2-weighted and non-breath-hold fast spin echo (NBHFSE) T2-weighted sequences in image quality and lesion characterisation of focal liver lesions. Materials and Methods: Fat-suppressed T2-weighted magnetic resonance (MR) images obtained with the 2 sequences (BHFRFSE and NBHFSE) in 79 patients with 113 liver lesions were analysed retrospectively. The image quality and nature of the lesions were evaluated by 2 experienced radiologists. Results: Based on receiver operating characteristic curve analysis, lesion characterisation was comparable for both sequences. The image quality of BHFRFSE was significantly better than that of NBHFSE. The NBHFSE missed 4 malignant lesions while BHFRFSE missed 2 malignant lesions. Conclusion: BHFRFSE performs similarly to NBHFSE in image quality and liver lesion characterisation.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 50 条
  • [11] T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
    Masui, T
    Katayama, M
    Kobayashi, S
    Sakahara, H
    Ito, T
    Nozaki, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 930 - 937
  • [12] A prospective assessment of breath-hold fast spin echo and inversion recovery fast spin echo techniques for detection and characterization of focal hepatic lesions
    Pawluk, RS
    Borrello, JA
    Brown, JJ
    McFarland, EG
    Mirowitz, SA
    Tsao, LY
    MAGNETIC RESONANCE IMAGING, 2000, 18 (05) : 543 - 551
  • [13] Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    Gaa, J
    Hatabu, H
    Jenkins, RL
    Finn, JP
    Edelman, RR
    RADIOLOGY, 1996, 200 (02) : 459 - 464
  • [14] Fast MR imaging of focal hepatic lesions: Comparison of breath-hold turbo SE, breath-hold HASTE, and breath-hold HASTE STIR versus conventional T2-weighted SE sequence
    Lee, M
    Jeong, YK
    Han, D
    Seo, DJ
    Auh, YH
    Chien, D
    RADIOLOGY, 1996, 201 : 435 - 435
  • [16] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [17] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393
  • [18] Breath-hold fast spin-echo MR imaging of Crohn's disease
    Ernst, O
    Asselah, T
    Cablan, X
    Sergent, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (01) : 127 - 128
  • [19] Evaluation of focal liver lesions: fast-recovery fast spin echo T2-weighted MR imaging
    Akin, Oguz
    Schwartz, Lawrence H.
    Welber, Adam
    Maier, Cynthia F.
    DeCorato, Douglas R.
    Panicek, David M.
    CLINICAL IMAGING, 2006, 30 (05) : 322 - 325
  • [20] Comparison of breath-hold multishot echo-planar and respiratory triggered fast-spin-echo sequences for T2-weighted MRI of liver lesions
    Yamakado, K
    Sakuma, H
    Murashima, S
    Nakatsuka, A
    Matsumura, K
    Takeda, K
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 432 - 437