A three-phase phase-locked loop algorithm with immunity to distorted signals employing an adaptive filter

被引:11
作者
de Araujo Lima, Francisco Kleber [1 ]
Araujo, Renato Guerreiro [1 ]
Tofoli, Fernando Lessa [2 ]
Castelo Branco, Carlos Gustavo [1 ]
机构
[1] Univ Fed Ceara, Dept Elect Engn, Fortaleza, Ceara, Brazil
[2] Univ Fed Sao Joao del Rei, Dept Elect Engn, Sao Joao Del Rei, MG, Brazil
关键词
Grid synchronization; Harmonics; Interharmonics; Phase-locked loop; Three-phase systems; POWER CONVERTERS; FREQUENCY; PLL; SYSTEM;
D O I
10.1016/j.epsr.2019.01.017
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a synchronization algorithm for the detection of the fundamental positive-sequence component in three-phase systems. The structure is based on the correlation of the input signal with a complex signal generated from the association of an adaptive filter and a phase-locked loop (PLL) method previously presented in literature. Good disturbance rejection is then achieved, in particular to interharmonics and sub-harmonics. Simulation and experimental results are presented and discussed in order to demonstrate the performance of the proposed solution when compared with that regarding dual second-order generalized integrator frequency locked Mop (DSOGI-FLL), which is often considered to present good disturbance rejection.
引用
收藏
页码:116 / 127
页数:12
相关论文
共 29 条
[1]   Three-phase single-stage grid tied solar PV ECS using PLL-less fast CTF control technique [J].
Agarwal, Rahul Kumar ;
Hussain, Ikhlaq ;
Singh, Bhim .
IET POWER ELECTRONICS, 2017, 10 (02) :178-188
[2]   An adaptive control algorithm for grid-interfacing inverters in renewable energy based distributed generation systems [J].
Al Sayari, Naji ;
Chilipi, Rajasekharareddy ;
Barara, Mohamad .
ENERGY CONVERSION AND MANAGEMENT, 2016, 111 :443-452
[3]  
[Anonymous], 2017, P 2017 INT C COMP CO
[4]   Overview of technical specifications for grid-connected photovoltaic systems [J].
Anzalchi, Arash ;
Sarwat, Arif .
ENERGY CONVERSION AND MANAGEMENT, 2017, 152 :312-327
[5]  
BENHABIB MC, 2005, P IEEE INT S IND EL, V2, P827
[6]   Application of Recursive Least Squares Algorithm With Variable Forgetting Factor for Frequency Component Estimation in a Generic Input Signal [J].
Beza, Mebtu ;
Bongiorno, Massimo .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (02) :1168-1176
[7]   Fault-Decoupled Instantaneous Frequency and Phase Angle Estimation for Three-Phase Grid-Connected Inverters [J].
De Donato, G. ;
Scelba, G. ;
Borocci, G. ;
Capponi, F. Giulii ;
Scarcella, G. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (04) :2880-2889
[8]   Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions [J].
Dong, Dong ;
Wen, Bo ;
Boroyevich, Dushan ;
Mattavelli, Paolo ;
Xue, Yaosuo .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (01) :310-321
[9]   On the Effects of Unbalances, Harmonics and Interharmonics on PLL Systems [J].
Feola, Luigi ;
Langella, Roberto ;
Testa, Alfredo .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (09) :2399-2409
[10]  
Gnacifiski P., 2017, 2017 19 EUR C POW EL