Calibration and characterization of a digital X-ray fluorescence bone lead system

被引:22
作者
Fleming, DEB [1 ]
Forbes, TA [1 ]
机构
[1] Univ Vermont, Dept Biomed Technol, Burlington, VT 05405 USA
关键词
bone lead; X-ray fluorescence; digital spectroscopy;
D O I
10.1016/S0969-8043(01)00075-6
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Five different combinations of digital shaping parameters were tested for a newly assembled, Cd-109 source, K X-ray fluorescence bone lead system. System calibration results are presented, along with analyses of measurement uncertainty and reproducibility obtained from repeat measurements of a bone phantom and a human tibia. Digital shaping parameters of 2.4 mus for a rise time/fall time and 1.2 mus for a flat top width were identified as superior. The digital system provided significant improvements in overall measurement precision, with gains of at least 25-35% over conventional system results. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 21 条
[1]   IMPROVEMENTS IN THE CALIBRATION OF CD-109-K X-RAY-FLUORESCENCE SYSTEMS FOR MEASURING BONE LEAD IN-VIVO [J].
ARO, ACA ;
TODD, AC ;
AMARASIRIWARDENA, C ;
HU, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (12) :2263-2271
[2]  
BARRY PSI, 1975, BRIT J IND MED, V32, P119
[3]   Performance appraisals of digital spectroscopy systems for the measurement of bone lead [J].
Bateman, SN ;
Pejovic-Milic, A ;
Stronach, IM ;
McNeill, FE ;
Chettle, DR .
APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) :647-650
[4]  
*CANB IND, 1999, MOD DSA 2000 DIG SPE, pB1
[5]  
CHRISTOFFERSSON JO, 1984, AM J IND MED, V6, P447, DOI 10.1002/ajim.4700060608
[6]   Determinants of bone and blood lead levels among teenagers living in urban areas with high lead exposure [J].
Farias, P ;
Hu, H ;
Rubenstein, E ;
Meneses-Gonzalez, F ;
Fishbein, E ;
Palazuelos, E ;
Aro, A ;
Hernandez-Avila, M .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1998, 106 (11) :733-737
[7]   Accumulated body burden and endogenous release of lead in employees of a lead smelter [J].
Fleming, DEB ;
Boulay, D ;
Richard, NS ;
Robin, JP ;
Gordon, CL ;
Webber, CE ;
Chettle, DR .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1997, 105 (02) :224-233
[8]   IN-VIVO MEASUREMENTS OF LEAD IN BONE IN LONG-TERM EXPOSED LEAD SMELTER WORKERS [J].
GERHARDSSON, L ;
ATTEWELL, R ;
CHETTLE, DR ;
ENGLYST, V ;
LUNDSTROM, NG ;
NORDBERG, GF ;
NYHLIN, H ;
SCOTT, MC ;
TODD, AC .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1993, 48 (03) :147-156
[9]  
GORDON CL, 1993, BRIT J IND MED, V50, P637
[10]   THE REPRODUCIBILITY OF CD-109-BASED X-RAY-FLUORESCENCE MEASUREMENTS OF BONE LEAD [J].
GORDON, CL ;
WEBBER, CE ;
CHETTLE, DR .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1994, 102 (08) :690-694