Simultaneous Wireless Power and Data Transfer: Methods to Design Robust Medical Implants for Gastrointestinal Tract

被引:14
作者
Javan-Khoshkholgh, Amir [1 ]
Farajidavar, Aydin [1 ]
机构
[1] New York Inst Technol, Integrated Med Syst IMS Lab, Coll Engn & Comp Sci, Old Westbury, NY 11568 USA
来源
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY | 2022年 / 6卷 / 01期
基金
美国国家卫生研究院;
关键词
Radio frequency; Electromagnetics; Biology; Three-dimensional displays; Microwave amplifiers; Transceivers; Power amplifiers; Biomedical implants; capacitive link; gastrointestinal tract; neural dust; resonant inductive link; ultrasonic link; wireless power transfer; wireless data transmission; BPSK DEMODULATOR; BACK TELEMETRY; TRANSCUTANEOUS POWER; DATA-TRANSMISSION; DATA LINK; DEVICE; IMPEDANCE; COMMUNICATION; RECTIFIER; CIRCUIT;
D O I
10.1109/JERM.2021.3084516
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Implantable medical systems for long-term monitoring of bioelectrical activity of the gastrointestinal (GI) tract, known as slow waves, and for treating GI dysmotility and functional disorders through electrical stimulation pulses have emerged over the recent years. These implants construct a bidirectional interface between the clinician and the patient's GI tract, to record and monitor slow waves and to provide electrical therapies. Because of the limited battery life of the implants, wireless power transfer (WPT) is a fundamental requirement to conduct studies and provide treatments for an extended period. Furthermore, the WPT link provides the opportunity to establish near-field data communication over the same link. Currently, there are three main wireless power and data transfer (WPDT) approaches for GI tract implants consisting of resonant inductive, ultrasonic, and capacitive couplings. Each approach provides a tradeoff based on the size of the implant, depth of implantation in vivo, the amount of power received by the implant, and the WPT efficiency. In this review, we present the theory and an overview of the major research works accomplished for each of the aforementioned WPT approaches. In particular, this paper focuses on simultaneous WPDT for systems implanted in the GI tract, while fluctuations of the wireless link efficiency and reliability due to body movements and stomach motility are investigated, and techniques are introduced to improve the WPDT fidelity.
引用
收藏
页码:3 / 15
页数:13
相关论文
共 113 条
[1]   An Inductive Link-Based Wireless Power Transfer System for Biomedical Applications [J].
Adeeb, M. ;
Islam, A. ;
Haider, M. ;
Tulip, F. ;
Ericson, M. ;
Islam, S. .
ACTIVE AND PASSIVE ELECTRONIC COMPONENTS, 2012, 2012
[2]   A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode [J].
Akin, T ;
Najafi, K ;
Bradley, RM .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1998, 33 (01) :109-118
[3]  
Alamouti SF, 2020, IEEE ENG MED BIO, P3289, DOI 10.1109/EMBC44109.2020.9176480
[4]   Design for a simplified cochlear implant system [J].
An, Soon Kwan ;
Park, Se-Ik ;
Jun, Sang Beom ;
Lee, Choong Jae ;
Byun, Kyung Min ;
Sung, Jung Hyun ;
Wilson, Blake S. ;
Rebscher, Stephen J. ;
Oh, Seung Ha ;
Kim, Sung June .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (06) :973-982
[5]  
[Anonymous], 2019, C9512019 IEEE, P1, DOI DOI 10.1109/IEEESTD.2019.8859679
[6]  
[Anonymous], 1999, Off. J. Eur. Commun., V199, P59
[7]   Controlling wireless power transfer by tuning and detuning resonance of telemetric devices for rodents [J].
Badr, Basem M. ;
Makosinski, Art ;
Dechev, Nikolai ;
Delaney, Kerry R. .
WIRELESS POWER TRANSFER, 2020, 7 (01) :19-32
[8]   Active High Power Conversion Efficiency Rectifier With Built-In Dual-Mode Back Telemetry in Standard CMOS Technology [J].
Bawa, Gaurav ;
Ghovanloo, Maysam .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2008, 2 (03) :184-192
[9]   Enabling Ultrasound In-Body Communication: FIR Channel Models and QAM Experiments [J].
Bos, Thomas ;
Jiang, Wentao ;
D'hooge, Jan ;
Verhelst, Marian ;
Dehaene, Wim .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (01) :135-144
[10]   An Implantable, Batteryless, and Wireless Capsule With Integrated Impedance and pH Sensors for Gastroesophageal Reflux Monitoring [J].
Cao, Hung ;
Landge, Vaibhav ;
Tata, Uday ;
Seo, Young-Sik ;
Rao, Smitha ;
Tang, Shou-Jiang ;
Tibbals, H. F. ;
Spechler, Stuart ;
Chiao, J-C .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (11) :3131-3139