Evaluating robotic pedicle screw placement against conventional modalities: a systematic review and network meta-analysis

被引:34
|
作者
Naik, Anant [1 ]
Smith, Alexander D. [1 ]
Shaffer, Annabelle [1 ]
Krist, David T. [1 ]
Moawad, Christina M. [1 ]
MacInnis, Bailey R. [1 ]
Teal, Kevin [1 ,2 ]
Hassaneen, Wael [1 ,2 ]
Arnold, Paul M. [1 ,2 ]
机构
[1] Univ Illinois, Carle Illinois Coll Med, Champaign, IL USA
[2] Carle Fdn Hosp, Carle Neurosci Inst, Dept Neurosurg, Urbana, IL USA
关键词
robotic navigation; pedicle screw; robotic spine surgery; network meta-analysis; CLINICAL ACCURACY; LUMBAR; SURGERY; SCALE;
D O I
10.3171/2021.10.FOCUS21509
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Several approaches have been studied for internal fixation of the spine using pedicle screws (PSs), including CT navigation, 2D and 3D fluoroscopy, freehand, and robotic assistance. Robot-assisted PS placement has been controversial because training requirements, cost, and previously unclear benefits. This meta-analysis compares screw placement accuracy, operative time, intraoperative blood loss, and overall complications of PS insertion using traditional freehand, navigated, and robot- assisted methods. METHODS A systematic review was performed of peer-reviewed articles indexed in several databases between January 2000 and August 2021 comparing >= 2 PS insertion methods with >= 10 screws per treatment arm. Data were extracted for patient outcomes, including PS placement, misplacement, and accuracy; operative time, overall complications, intraoperative blood loss, postoperative hospital length of stay, postoperative Oswestry Disability Index (ODI) score, and postoperative visual analog scale (VAS) score for back pain. Risk of bias was assessed using the NewcastleOttawa score and Cochrane tool. A network meta-analysis (NMA) was performed to estimate PS placement accuracy as the primary outcome. RESULTS Overall, 78 studies consisting of 6262 patients and > 31,909 PSs were included. NMA results showed that robot-assisted and 3D-fluoroscopy PS insertion had the greatest accuracy compared with freehand (p < 0.01 and p < 0.001, respectively), CT navigation (p = 0.02 and p = 0.04, respectively), and 2D fluoroscopy (p < 0.01 and p < 0.01, respectively). The surface under the cumulative ranking (SUCRA) curve method further demonstrated that robotassisted PS insertion accuracy was superior (S = 0.937). Optimal screw placement was greatest in robot-assisted (S = 0.995) placement, and misplacement was greatest with freehand (S = 0.069) approaches. Robot- assisted placement was favorable for minimizing complications (S = 0.876), while freehand placement had greater odds of complication than robot-assisted (OR 2.49, p < 0.01) and CT-navigation (OR 2.15, p = 0.03) placement. CONCLUSIONS The results of this NMA suggest that robot- assisted PS insertion has advantages, including improved accuracy, optimal placement, and minimized surgical complications, compared with other PS insertion methods. Limitations included overgeneralization of categories and time-dependent effects.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Robotic-Assisted Versus Fluoroscopic-Guided Surgery on the Accuracy of Spine Pedicle Screw Placement: A Systematic Review and Meta-Analysis
    Jung, Bongseok
    Han, Justin
    Shahsavarani, Shaya
    Abbas, Anas M.
    Echevarria, Alexandra C.
    Carrier, Robert E.
    Ngan, Alex
    Katz, Austen D.
    Essig, David
    Verma, Rohit
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [2] Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis
    Hao Liu
    Weikai Chen
    Zongyi Wang
    Jun Lin
    Bin Meng
    Huilin Yang
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 2273 - 2281
  • [3] Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis
    Liu, Hao
    Chen, Weikai
    Wang, Zongyi
    Lin, Jun
    Meng, Bin
    Yang, Huilin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (12) : 2273 - 2281
  • [4] Pedicle screw placement accuracy - A meta-analysis
    Kosmopoulos, Victor
    Schizas, Constantin
    SPINE, 2007, 32 (03) : E111 - E120
  • [5] Comparative efficacy of robotic-assisted and freehand techniques for pedicle screw placement in spinal disorders: a meta-analysis and systematic review
    Yang, Zhanhua
    Sun, Yuhang
    Deng, Changcui
    Dong, Xiuhui
    Hao, Liansheng
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [6] Trends in Technology for Pedicle Screw Placement A Temporal Meta-Analysis
    Naik, Anant
    MacInnis, Bailey R. R.
    Shaffer, Annabelle
    Krist, David T. T.
    Smith, Alexander D. D.
    Garst, Jonathan R. R.
    Hassaneen, Wael
    Arnold, Paul M. M.
    SPINE, 2023, 48 (11) : 791 - 799
  • [7] Accuracy of Pedicle Screw Placement Methods in Pediatrics and Adolescents Spinal Surgery: A Systematic Review and Meta-Analysis
    De Vega, Brigita
    Navarro, Aida Ribera
    Gibson, Alexander
    Kalaskar, Deepak M.
    GLOBAL SPINE JOURNAL, 2022, 12 (04) : 677 - 688
  • [8] Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws
    Verma, Rajeev
    Krishan, Sonal
    Haendlmayer, Kurt
    Mohsen, A.
    EUROPEAN SPINE JOURNAL, 2010, 19 (03) : 370 - 375
  • [9] Pedicle Screw Insertion: Is O-Arm-Based Navigation Superior to the Conventional Freehand Technique? A Systematic Review and Meta-Analysis
    Sun, Jun
    Wu, Dongying
    Wang, Qiuan
    Wei, Yangyang
    Yuan, Feng
    WORLD NEUROSURGERY, 2020, 144 : E87 - E99
  • [10] Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis
    Yu, Chengqiang
    Ou, Yufu
    Xie, Chengxin
    Zhang, Yu
    Wei, Jianxun
    Mu, Xiaoping
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)