Performance comparison of a double-axis sun tracking versus fixed PV system

被引:154
作者
Eke, Rustu [1 ]
Senturk, Ali
机构
[1] Mugla Sitki Kocman Univ, Clean Energy Res & Dev Ctr, TR-48120 Mugla, Turkey
关键词
Double axis tracking system; Photovoltaic; PV performance;
D O I
10.1016/j.solener.2012.06.006
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the present study, performance results of two double axis sun tracking photovoltaic (PV) systems are analyzed after one year of operation. Two identical 7.9 kWp PV systems with the same modules and inverters were installed at Mugla University campus in October 2009. Measured data of the PV systems are compared with the simulated data. The performance measurements of the PV systems were carried out first when the PV systems were in a fixed position and then the PV systems were controlled while tracking the sun in two axis (on azimuth and solar altitude angles) and the necessary measurements were performed. Annual PV electricity yield is calculated as 11.53 MW h with 1459 kW h/kWp energy rating for 28 fixed tilt angle for each system. It is calculated that 30.79% more PV electricity is obtained in the double axis sun-tracking system when compared to the latitude tilt fixed system. The annual PV electricity fed to grid is 15.07 MW h with 1908 kW h/kWp for the double axis sun-tracking PV system between April-2010 and March-2011. The difference between the simulated and measured energy values are less than 5%. The results also allow the comparison of different solutions and the calculation of the electricity output. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2665 / 2672
页数:8
相关论文
共 20 条
[1]   Two axes sun tracking system with PLC control [J].
Abdallah, S ;
Nijmeh, S .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (11-12) :1931-1939
[2]   Efficiency improvements of photo-voltaic panels using a Sun-tracking system [J].
Al-Mohamad, A .
APPLIED ENERGY, 2004, 79 (03) :345-354
[3]  
[Anonymous], P 23 EUR PHOT SOL EN
[4]   Environmental assessment of grid connected photovoltaic plants with 2-axis tracking versus fixed modules systems [J].
Bayod-Rujula, Angel A. ;
Lorente-Lafuente, Ana M. ;
Cirez-Oto, Fernando .
ENERGY, 2011, 36 (05) :3148-3158
[5]  
Eke Rustu, 2010, Proceedings of the 25th European Photovoltaic Solar Energy Conference and Exhibition and the 5th World Conference on Photovoltaic Energy Conversion, P4744
[6]  
Eke R., 2000, THESIS MUGLA U
[7]  
Gay C. F., 1982, Conference Record of the Sixteenth IEEE Photovoltaic Specialists Conference - 1982, P1368
[8]   Solar Cell Efficiency Tables (Version 34) [J].
Green, Martin A. ;
Emery, Keith ;
Hishikawa, Yoshihiro ;
Warta, Wilhelm .
PROGRESS IN PHOTOVOLTAICS, 2009, 17 (05) :320-326
[9]   Long-term field test of solar PV power generation using one-axis 3-position sun tracker [J].
Huang, B. J. ;
Ding, W. L. ;
Huang, Y. C. .
SOLAR ENERGY, 2011, 85 (09) :1935-1944
[10]   Improved photovoltaic energy output for cloudy conditions with a solar tracking system [J].
Kelly, Nelson A. ;
Gibson, Thomas L. .
SOLAR ENERGY, 2009, 83 (11) :2092-2102