Cost and complications associated with implant-supported overdentures with a resilient-attachment system: A retrospective study

被引:8
|
作者
Patodia, Chetan [1 ]
Sutton, Alan [2 ]
Gozalo, David [2 ]
Font, Kerri [1 ]
机构
[1] Univ Colorado, Dept Surg Dent, Sch Dent Med, Grad Periodont Program, Aurora, CO USA
[2] Univ Colorado, Dept Restorat Dent, Sch Dent Med, Aurora, CO USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 128卷 / 02期
关键词
MAINTENANCE REQUIREMENTS; RETAINED OVERDENTURES; PROSTHESES;
D O I
10.1016/j.prosdent.2020.11.040
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant-supported overdentures with a splinted or nonsplinted attachment system have been a successful treatment option for edentulous mandibles with excessive hard tissue resorption. Currently, the 2 most common treatment approaches for an implant overdenture uses either a bar attachment system (splinted) or resilient (LOCATOR)-attachment system (nonsplinted). The LOCATOR-attachment system is often chosen for the lower initial cost. However, whether the ongoing maintenance costs of the LOCATOR-attachment system increase the overall cost of this system is unclear. Purpose. The purpose of this retrospective study was to investigate the frequency of maintenance procedures, complications, and costs associated with the LOCATOR-supported overdenture treatment. Material and methods. The retrospective data of 75 patients who had received implant-supported overdentures with LOCATOR-attachments at the University of Colorado School of Dental Medicine in the previous 10 years were collected and screened to evaluate the number of maintenance visits, type of complications, and cost (actual fees for the service) of the maintenance visits. The data were analyzed, and the mean values calculated. Results. The average number of maintenance visits was 7.7 in the mean observation time of 5.2 years. Replacement of the attachment was the most frequent complication (63%). The average maintenance cost charged to the patient for maintenance was 56.2% ($795) of the initial cost over the average 5.2 years of follow-up. The average total maintenance cost (actual fees for the service) was 95.4% ($1349) of the initial cost over the average of 5.2 years of follow-up. The average maintenance cost adjusted or lost over the 5.2 years follow-up was 39.2%. Conclusions. The 5-year costs for the maintenance of mandibular overdentures with a LOCATOR-attachment system were equal to or higher than the initial cost of the treatment. The number of maintenance visits and the cost were higher for patients who were older than 75 years.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [41] In vitro comparison of change in retentive force values of three different attachment systems for two implant-supported overdentures
    Fernandes, Donato Savio
    Anasane, Nayana S.
    Jagtap, Amit K.
    Fernandes, Christie Michael
    FRONTIERS OF ORAL AND MAXILLOFACIAL MEDICINE, 2025, 7
  • [42] Attachment systems for mandibular implant-supported overdentures: A systematic review and meta-analysis of randomized controlled trials
    Prasad, Soni
    Faverani, Leonardo P.
    Santiago, Joel Ferreira
    Sukotjo, Cortino
    Yuan, Judy Chia-Chun
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 354 - 368
  • [43] Clips vs Resilient Liners Used With Bilateral Posterior Prefabricated Bars for Retaining Four Implant-Supported Mandibular Overdentures
    Gibreel, Mona
    Fouad, Mohammed
    El-Waseef, Fatma
    El-Amier, Nesma
    Marzook, Hamdy
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (04) : 273 - 281
  • [44] A retrospective study on the success of implant-supported single crowns.
    Hamed, M
    DaSilva, J
    Morgano, S
    Douglass, C
    Bosch, R
    Weyant, R
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 529 - 529
  • [45] Effect of implant number on the movement of mandibular implant-supported overdentures under biting force: An in-vitro study
    Zhang, Xin
    Liu, Wei
    Qing, Hai
    Pei, Xibo
    Chen, Junyu
    Wang, Jian
    QUINTESSENCE INTERNATIONAL, 2018, 49 (09): : 709 - 717
  • [46] Fabrication of a Mandibular Implant-Supported Overdenture with a New Attachment System: A Review of Current Attachment Systems
    Shah, Karnik
    Yilmaz, Burak
    McGlumphy, Edwin
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (03) : 245 - 247
  • [47] Effect of Simulated Mastication on the Retention of Locator Attachments for Implant-Supported Overdentures: An In Vitro Pilot Study
    Tehini, Georges
    Baba, Nadim Z.
    Berberi, Antoine
    Majzoub, Zeina
    Bassal, Hussein
    Rifai, Khaldoun
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (01): : 74 - 79
  • [48] Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient
    Ha, Seung-Ryong
    Kim, Sung-Hun
    Song, Seung-Il
    Hong, Seong-Tae
    Kim, Gy-Young
    JOURNAL OF ADVANCED PROSTHODONTICS, 2012, 4 (04): : 254 - 258
  • [49] A new classification of peri-implant bone morphology: a radiographic study of patients with lower implant-supported mandibular overdentures
    Zhang, Lei
    Geraets, Wil
    Zhou, Yongsheng
    Wu, Wuqing
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 905 - 909
  • [50] Does the retention system influence the stability of implant-supported maxillary overdentures? A comparison with fixed and conventional dentures
    Michelon, M. M. M.
    Posch, A. T.
    Sampaio-Filho, H. R.
    Lourenco, E. J. V.
    Telles, D. M.
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (01) : 47 - 51