Cost and complications associated with implant-supported overdentures with a resilient-attachment system: A retrospective study

被引:8
|
作者
Patodia, Chetan [1 ]
Sutton, Alan [2 ]
Gozalo, David [2 ]
Font, Kerri [1 ]
机构
[1] Univ Colorado, Dept Surg Dent, Sch Dent Med, Grad Periodont Program, Aurora, CO USA
[2] Univ Colorado, Dept Restorat Dent, Sch Dent Med, Aurora, CO USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 128卷 / 02期
关键词
MAINTENANCE REQUIREMENTS; RETAINED OVERDENTURES; PROSTHESES;
D O I
10.1016/j.prosdent.2020.11.040
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant-supported overdentures with a splinted or nonsplinted attachment system have been a successful treatment option for edentulous mandibles with excessive hard tissue resorption. Currently, the 2 most common treatment approaches for an implant overdenture uses either a bar attachment system (splinted) or resilient (LOCATOR)-attachment system (nonsplinted). The LOCATOR-attachment system is often chosen for the lower initial cost. However, whether the ongoing maintenance costs of the LOCATOR-attachment system increase the overall cost of this system is unclear. Purpose. The purpose of this retrospective study was to investigate the frequency of maintenance procedures, complications, and costs associated with the LOCATOR-supported overdenture treatment. Material and methods. The retrospective data of 75 patients who had received implant-supported overdentures with LOCATOR-attachments at the University of Colorado School of Dental Medicine in the previous 10 years were collected and screened to evaluate the number of maintenance visits, type of complications, and cost (actual fees for the service) of the maintenance visits. The data were analyzed, and the mean values calculated. Results. The average number of maintenance visits was 7.7 in the mean observation time of 5.2 years. Replacement of the attachment was the most frequent complication (63%). The average maintenance cost charged to the patient for maintenance was 56.2% ($795) of the initial cost over the average 5.2 years of follow-up. The average total maintenance cost (actual fees for the service) was 95.4% ($1349) of the initial cost over the average of 5.2 years of follow-up. The average maintenance cost adjusted or lost over the 5.2 years follow-up was 39.2%. Conclusions. The 5-year costs for the maintenance of mandibular overdentures with a LOCATOR-attachment system were equal to or higher than the initial cost of the treatment. The number of maintenance visits and the cost were higher for patients who were older than 75 years.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [21] A comparative in vitro study on the retention and stability of implant-supported overdentures
    Sadig, Walid
    QUINTESSENCE INTERNATIONAL, 2009, 40 (04): : 313 - 319
  • [22] The effect of attachment systems and denture cleaning methods on microbial biomass and composition in implant-supported overdentures: an experimental study
    Zhao, Yuwei
    Yang, Xin
    Wen, Bixin
    Li, Yuqing
    Yu, Haiyang
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [23] Retrospective evaluation of implant-supported overdenture treatments: prosthetic complications
    Sampaio-Fernandes, Margarida
    Vaz, Paula Cristina
    Braga, Ana Cristina
    Figueiral, Maria Helena
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2016, 57 (01): : 14 - 20
  • [24] Effects of attachment clips on occlusal force transmission in removable implant-supported overdentures and cantilevered superstructures
    Kayacan, R
    Ballarini, R
    Mullen, RL
    Wang, RR
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (02) : 228 - 236
  • [25] Implant-supported overdenture therapy: A retrospective study
    Ekfeldt, A
    Johansson, LA
    Isaksson, S
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1997, 10 (04) : 366 - 374
  • [26] Influence of different polymeric materials of implant and attachment on stress distribution in implant-supported overdentures: a three-dimensional finite element study
    Elsayed, Sherif
    Ahmed, Yousra
    El-Anwar, Mohamed I.
    Elddamony, Enas
    Ashraf, Reem
    BMC ORAL HEALTH, 2025, 25 (01):
  • [27] Association Between Peri-implant Bone Morphology and Marginal Bone Loss: A Retrospective Study on Implant-Supported Mandibular Overdentures
    Ding, Qian
    Zhang, Lei
    Geraets, Wil
    Wu, Wuqing
    Zhou, Yongsheng
    Wismeijer, Daniel
    Xie, Qiufei
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 147 - 155
  • [28] What is the Impact of Implant-supported Mandibular Overdentures on Oral Health-Related Quality of Life? A Retrospective Study
    Altay, Mehmet Ali
    Ozarslan, Mehmet Mustafa
    Yildirimyan, Nelli
    Sindel, Alper
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2019, 9 (02): : 101 - 105
  • [29] Clinical Evaluation of Complications in Implant-Supported Dentures: A 4-Year Retrospective Study
    Ulku, Sabiha Zelal
    Kaya, Filiz Acun
    Uysal, Ersin
    Gulsun, Belgin
    MEDICAL SCIENCE MONITOR, 2017, 23 : 6137 - 6143
  • [30] Patients experience and satisfaction with immediate loading of implant-supported overdentures - A qualitative study
    Shrivastava, Richa
    Luxenberg, Ryan
    Sutton, Edward
    Emami, Elham
    JOURNAL OF DENTISTRY, 2023, 137