A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT

被引:53
作者
DePuey, E. Gordon [1 ]
Bommireddipalli, Srinivas
Clark, John
Leykekhman, Anna
Thompson, Linda B.
Friedman, Marvin
机构
[1] St Lukes Roosevelt Hosp, Dept Radiol, Div Nucl Med, New York, NY 10025 USA
关键词
Gated SPECT; image processing; instrumentation: SPECT; iterative reconstruction; radiation dosimetry;
D O I
10.1007/s12350-011-9340-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Wide Beam Reconstruction (WBR) (UltraSPECT, Ltd) uses resolution recovery and noise modeling to cope with decreased SPECT count statistics. Because WBR processing reconstructs half the usual SPECT count statistics, we postulate that image quality equivalent to a full-time acquisition can be achieved in either half the time or with half the radiopharmaceutical activity. In 156 consecutive patients (pts) rest and 8-frame gated post-stress myocardial perfusion SPECT was performed following 333-444 and 1184-1480 MBq (9-12 and 32-40 mCi) Tc-99m sestamibi injections, respectively, with full-time (rest = 14 min; stress = 12.3 min) acquisitions processed with OSEM and also separate "half-time" acquisitions processed with WBR. A subsequent group of 160 consecutive pts matched in gender, weight, and chest circumference received "half-dose" rest and stress injections 214.6 +/- A 22.2 and 647.5 +/- A 92.5 MBq (5.8 +/- A 0.6 and 17.5 +/- A 2.5 mCi) with full-time SPECT acquisitions. Image quality (1 = poor to 5 = excellent) was judged by myocardial count density and uniformity, endocardial edge definition, perfusion defect delineation, right ventricular visualization, and background noise. Mean image quality for rest, stress, and post-stress gated images were 3.6 +/- A 0.7, 3.8 +/- A 0.7, and 3.9 +/- A 1.0, respectively, for "full-time OSEM; 3.7 +/- A 0.8, 4.0 +/- A 0.7, and 4.8 +/- A 0.4 for "half-time" WBR; and 4.3 +/- A 0.8, 4.6 +/- A 0.6, and 4.7 +/- A 0.6 for "half-dose" WBR. "Half-time" and "half-dose" WBR image quality were both superior to standard full-time OSEM (P's < .001). There was no significant difference between the summed stress and rest scores for "full-time" OSEM vs "half-time" WBR in 82 patients with perfusion defects. Both "half-time" and "half-dose" WBR provide myocardial perfusion SPECT quality superior to full-time OSEM, with an associated decrease in scan acquisition time and patient radiation exposure, respectively.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 13 条
[1]  
Bogdanich W, 2010, NY TIMES, pB7
[2]   Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies [J].
Borges-Neto, Salvador ;
Pagnanelli, Robert A. ;
Shaw, Linda K. ;
Honeycutt, Emily ;
Shwartz, Shuli C. ;
Adams, George L. ;
Coleman, Ralph Edward .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :555-565
[3]   Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection [J].
DePuey, E. Gordon ;
Gadiraju, Ramesh ;
Clark, John ;
Thompson, Linda ;
Anstett, Frank ;
Shwartz, Shuli C. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (04) :547-563
[4]   Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum [J].
DePuey, E. Gordon ;
Bommireddipalli, Srinivas ;
Clark, John ;
Thompson, Linda ;
Srour, Yossi .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (05) :736-752
[5]   New software methods to cope with reduced counting statistics: shorter SPECT acquisitions and many more possibilities [J].
DePuey, E. Gordon .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (03) :335-338
[6]   Radiation dose to patients from cardiac diagnostic imaging [J].
Einstein, Andrew J. ;
Moser, Kevin W. ;
Thompson, Randall C. ;
Cerqueira, Manuel D. ;
Henzlova, Milena J. .
CIRCULATION, 2007, 116 (11) :1290-1305
[7]   The Year in Cardiac Imaging [J].
Gibbons, Raymond J. ;
Araoz, Philip A. ;
Williamson, Eric E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (01) :54-70
[8]   Stress-Only Myocardial Perfusion Imaging A New Paradigm [J].
Iskandrian, Ami E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (03) :231-233
[9]   Prospective multicenter evaluation of rapid, gated SPECT myocardial perfusion upright imaging [J].
Maddahi, Jamshid ;
Mendez, Ricardo ;
Mahmarian, John J. ;
Thomas, Gregory ;
Babla, Hetal ;
Bai, Chuanyong ;
Arram, Samia ;
Maffetone, Peter ;
Conwell, Richard .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (03) :351-357
[10]   High-Speed Myocardial Perfusion Imaging Initial Clinical Comparison With Conventional Dual Detector Anger Camera Imaging [J].
Sharir, Tali ;
Ben-Haim, Simona ;
Merzon, Konstantine ;
Prochorov, Vitali ;
Dickman, Dalia ;
Ben-Haim, Shlomo ;
Berman, Daniel S. .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (02) :156-163