A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II)

被引:87
作者
Lu, Zhiwei [1 ]
Zhang, Junjun [1 ,2 ]
Dai, Wanlin [1 ]
Lin, Xueni [1 ]
Ye, Jiaping [3 ]
Ye, Jianshan [1 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Guangzhou 510641, Guangdong, Peoples R China
[2] Guangdong Pharmaceut Univ, Sch Chem & Chem Engn, Guangzhou 510006, Guangdong, Peoples R China
[3] Guangzhou Ingsens Sensor Technol Co Ltd, Kaiyuan Rd 11, Guangzhou 510535, Guangdong, Peoples R China
关键词
Disposable sensor; Electrochemical detection; Differential pulse anodic stripping voltammetry; Cyclic voltammetry; Electrochemical impedance spectroscopy; Heavy metal ions; SENSITIVE ELECTROCHEMICAL SENSOR; NANOTUBE PASTE ELECTRODE; HEAVY-METAL IONS; REAL SAMPLES; LEAD; CADMIUM; ZINC; NANOCOMPOSITE; FABRICATION; BEHAVIOR;
D O I
10.1007/s00604-017-2521-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors report on a disposable sensor for the differential pulse anodic stripping voltammetric (DPASV) determination of the ions Zn(II), Pb(II) and Cu(II). Simultaneous detection is accomplished by using a screen-printed carbon electrode (SPCE) co-modified with an in-situ plated bismuth (Bi)) film and gold nanoparticles (AuNPs). The synergistic effect of the Bi film, and the large surface and good electrical conductivity of the AuNPs strongly assist in the co-deposition of the three ions. Four well-defined and fully separated anodic stripping peaks, at 540 mV for Zn(II), 50 mV for Pb(II), 140 mV for Bi(III) and 295 mV for Cu(II), all vs. Ag/AgCl, can be seen. The modified SPCE was characterized by scanning electron microscopy, X-ray diffraction, cyclic voltammetry and electrochemical impedance spectroscopy. Under the optimized conditions, the sensor has a good response to these ions. The detection limits (at an S/N ratio of 3) are 50 ng.L-1 for Zn(II), 20 ngL(-1) for Pb(II), and 30 ng.L-1 for Cu(II). The method was applied to the determination of the 3 ions in spiked lake water samples.
引用
收藏
页码:4731 / 4740
页数:10
相关论文
共 35 条
[1]   Speciation of heavy metals in environmental water by ion chromatography coupled to ICP-MS [J].
Ammann, AA .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (03) :448-452
[2]   Screen-printed electrodes for environmental monitoring of heavy metal ions: a review [J].
Barton, John ;
Gonzalez Garcia, Maria Begona ;
Hernandez Santos, David ;
Fanjul-Bolado, Pablo ;
Ribotti, Alberto ;
McCaul, Margaret ;
Diamond, Dermot ;
Magni, Paolo .
MICROCHIMICA ACTA, 2016, 183 (02) :503-517
[3]   Preparation, characterization and electrochemical application of Ag-ZnO nanoplates for voltammetric determination of glutathione and tryptophan using modified carbon paste electrode [J].
Beitollahi, Hadi ;
Gholami, Abbas ;
Ganjali, Mohammad Reza .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 57 :107-112
[4]   Electrochemical determination of sulfite and phenol using a carbon paste electrode modified with ionic liquids and graphene nanosheets: Application to determination of sulfite and phenol in real samples [J].
Beitollahi, Hadi ;
Tajik, Somayeh ;
Biparva, Pourya .
MEASUREMENT, 2014, 56 :170-177
[5]   Electrocatalytic determination of captopril using a modified carbon nanotube paste electrode: Application to determination of captopril in pharmaceutical and biological samples [J].
Beitollahi, Hadi ;
Taher, Mohammad Ali ;
Ahmadipour, Malihe ;
Hosseinzadeh, Rahman .
MEASUREMENT, 2014, 47 :770-776
[6]   Removal of heavy metals from aqueous solution by sawdust adsorption [J].
Bulut, Yasemin ;
Tez, Zeki .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2007, 19 (02) :160-166
[7]   Electrochemical sensors for the simultaneous determination of zinc, cadmium and lead using a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode [J].
Chaiyo, Sudkate ;
Mehmeti, Eda ;
Zagar, Kristina ;
Siangproh, Weena ;
Chailapakul, Orawon ;
Kalcher, Kurt .
ANALYTICA CHIMICA ACTA, 2016, 918 :26-34
[8]   Bismuth-based porous screen-printed carbon electrode with enhanced sensitivity for trace heavy metal detection by stripping voltammetry [J].
Chen, Chen ;
Niu, Xiangheng ;
Chai, Yan ;
Zhao, Hongli ;
Lan, Minbo .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 :339-342
[9]   A sensitive electrochemical sensor for lead based on gold nanoparticles/nitrogen-doped graphene composites functionalized with L-cysteine-modified electrode [J].
Cheng, Yan-mei ;
Fa, Huan-bao ;
Yin, Wei ;
Hou, Chang-jun ;
Huo, Dan-qun ;
Liu, Fang-mei ;
Zhang, Ya ;
Chen, Can .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2016, 20 (02) :327-335
[10]   Simultaneous determination of zinc, copper, lead, and cadmium in fuel ethanol by anodic stripping voltammetry using a glassy carbon-mercury-film electrode [J].
de Oliveira, MF ;
Saczk, AA ;
Okumura, LL ;
Fernandes, AP ;
de Moraes, M ;
Stradiotto, NR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) :135-140