Relationship between kurtosis and bi-exponential characterization of high b-value diffusion-weighted imaging: application to prostate cancer

被引:9
|
作者
Karunamuni, Roshan A. [1 ]
Kuperman, Joshua [2 ]
Seibert, Tyler M. [1 ]
Schenker, Natalie [2 ]
Rakow-Penner, Rebecca [2 ]
Sundar, Vs [2 ]
Teruel, Jose R. [2 ]
Goa, Pal E. [3 ]
Karow, David S. [2 ]
Dale, Anders M. [2 ]
White, Nathan S. [2 ]
机构
[1] Univ Calif San Diego, Dept Radiat Med & Appl Sci, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[3] Norwegian Univ Sci & Technol, Dept Phys, Trondheim, Norway
关键词
Diffusion; magnetic resonance imaging; MRI; prostate; neoplasm; WATER DIFFUSION; MRI; EXPERIENCE; OUTCOMES;
D O I
10.1177/0284185118770889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: High b-value diffusion-weighted imaging has application in the detection of cancerous tissue across multiple body sites. Diffusional kurtosis and bi-exponential modeling are two popular model-based techniques, whose performance in relation to each other has yet to be fully explored. Purpose: To determine the relationship between excess kurtosis and signal fractions derived from bi-exponential modeling in the detection of suspicious prostate lesions. Material and Methods: This retrospective study analyzed patients with normal prostate tissue (n = 12) or suspicious lesions (n = 13, one lesion per patient), as determined by a radiologist whose clinical care included a high b-value diffusion series. The observed signal intensity was modeled using a bi-exponential decay, from which the signal fraction of the slow-moving component was derived (SFs). In addition, the excess kurtosis was calculated using the signal fractions and ADCs of the two exponentials (KCOMP). As a comparison, the kurtosis was also calculated using the cumulant expansion for the diffusion signal (KCE). Results: Both K and KCE were found to increase with SFs within the range of SFs commonly found within the prostate. Voxel-wise receiver operating characteristic performance of SFs, KCE, and KCOMP in discriminating between suspicious lesions and normal prostate tissue was 0.86 (95% confidence interval [CI] = 0.85 - 0.87), 0.69 (95% CI = 0.68-0.70), and 0.86 (95% CI= 0.86-0.87), respectively. Conclusion: In a two-component diffusion environment, KCOMP is a scaled value of SFs and is thus able to discriminate suspicious lesions with equal precision. KCE provides a computationally inexpensive approximation of kurtosis but does not provide the same discriminatory abilities as SFs and KCOMP.
引用
收藏
页码:1523 / 1529
页数:7
相关论文
共 50 条
  • [41] In vivo brain edema classification:: New insight offered by large b-value diffusion-weighted MR imaging
    Schwarcz, Attila
    Ursprung, Zsuzsa
    Berente, Zoltan
    Bogner, Peter
    Kotek, Gyula
    Meric, Philippe
    Gillet, Brigitte
    Beloeil, Jean-Claude
    Doczi, Tamas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 26 - 31
  • [42] Feasibility of Computed Diffusion Weighted Imaging and Optimization of b-value in Cervical Cancer
    Moribata, Yusaku
    Kido, Aki
    Fujimoto, Koji
    Himoto, Yuki
    Kurata, Yasuhisa
    Shitano, Fuki
    Kiguchi, Kayo
    Konishi, Ikuo
    Togashi, Kaori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (01) : 66 - 72
  • [43] Diagnostic accuracy of high b-value diffusion weighted imaging for patients with prostate cancer: a diagnostic comprehensive analysis
    Li, Chao
    Li, Na
    Li, Zhanzhan
    Shen, Liangfang
    AGING-US, 2021, 13 (12): : 16404 - 16424
  • [44] Ultra-High b-Value Diffusion-Weighted Imaging-Based Abbreviated Protocols for Breast Cancer Detection
    Ohlmeyer, Sabine
    Laun, Frederik Bernd
    Bickelhaupt, Sebastian
    Palm, Theresa
    Janka, Rolf
    Weiland, Elisabeth
    Uder, Michael
    Wenkel, Evelyn
    INVESTIGATIVE RADIOLOGY, 2021, 56 (10) : 629 - 636
  • [45] Hidden Infarcts Detected by a High b-Value Diffusion-Weighted Imaging: A Parameter-Optimized Study
    Song, Xiubao
    Xu, Xi
    Ye, Yufeng
    Liang, Jianye
    Ma, Mengjie
    Peng, Qiwen
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (02) : 308 - 313
  • [46] Comparison of Computed Diffusion-Weighted Imaging b2000 and Acquired Diffusion-Weighted Imaging b2000 for Detection of Prostate Cancer
    Kim, Yeon Jung
    Kim, Seung Ho
    Baek, Tae Wook
    Park, Hyungin
    Lim, Yun-jung
    Jung, Hyun Kyung
    Kim, Joo Yeon
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2022, 83 (05): : 1059 - 1070
  • [47] High b-value diffusion-weighted imaging: A sensitive method to reveal white matter differences in schizophrenia
    Baumann, Philipp Sebastian
    Cammoun, Leila
    Conus, Philippe
    Do, Kim Quang
    Marquet, Pierre
    Meskaldji, Djalel
    Meuli, Reto
    Thiran, Jean-Philippe
    Hagmann, Patric
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2012, 201 (02) : 144 - 151
  • [48] Why Is a b-value Range of 1500-2000 s/mm2 Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?
    Cha, So Yeon
    Kim, EunJu
    Park, Sung Yoon
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (06) : 922 - 930
  • [49] High b-value diffusion-weighted MRI for detecting gallbladder carcinoma: preliminary study and results
    Sugita, Reiji
    Yamazaki, Tetsuro
    Furuta, Akemi
    Itoh, Kei
    Fujita, Naotaka
    Takahashi, Shoki
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1794 - 1798
  • [50] Comparison of the Diagnostic Value of Mono-exponential, Bi-exponential, and Stretched Exponential Signal Models in Diffusion-weighted MR Imaging for Differentiating Benign and Malignant Hepatic Lesions
    Noda, Yoshifumi
    Goshima, Satoshi
    Fujimoto, Keita
    Akamine, Yuta
    Kajita, Kimihiro
    Kawai, Nobuyuki
    Matsuo, Masayuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 69 - 75