Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

被引:19
作者
Jang, Yeon [1 ]
Sim, Ji-Young [1 ]
Park, Jong-Kyoung [1 ,2 ]
Kim, Woong-Chul [1 ]
Kim, Hae-Young [3 ]
Kim, Ji-Hwan [1 ]
机构
[1] Korea Univ, Coll Hlth Sci, Dept Dent Lab Sci & Engn, Seoul, South Korea
[2] Korea Univ, Coll Hlth Sci, Res Inst Hlth Sci, Seoul, South Korea
[3] Korea Univ, Grad Sch, Dept Publ Hlth Sci, Seoul, South Korea
关键词
Marginal and internal fit; Intra oral scanner; Digital light processing; 3D printing model; PolyJet; CONVENTIONAL IMPRESSIONS; DIGITAL IMPRESSIONS; IN-VITRO; ACCURACY; 3D; REPRODUCIBILITY; PROSTHODONTICS; TECHNOLOGY; ADAPTATION; THICKNESS;
D O I
10.4047/jap.2018.10.5.367
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (alpha=.05). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<120 mu m).
引用
收藏
页码:367 / 373
页数:7
相关论文
共 27 条
[1]   Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions [J].
Anadioti, Evanthia ;
Aquilino, Steven A. ;
Gratton, David G. ;
Holloway, Julie A. ;
Denry, Isabelle L. ;
Thomas, Geb W. ;
Qian, Fang .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (04) :304-309
[2]   3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions [J].
Anadioti, Evanthia ;
Aquilino, Steven A. ;
Gratton, David G. ;
Holloway, Julie A. ;
Denry, Isabelle ;
Thomas, Geb W. ;
Qian, Fang .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08) :610-617
[3]  
Boitelle P, 2016, INT J COMPUT DENT, V19, P27
[4]   Comparison of accuracy and reproducibility of casts made by digital and conventional methods [J].
Cho, Seok-Hwan ;
Schaefer, Oliver ;
Thompson, Geoffrey A. ;
Guentsch, Arndt .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (04) :310-315
[5]  
Chochlidakis KM, 2016, J PROSTHET DENT, V116, P184, DOI 10.1016/j.prosdent.2015.12.017
[6]   3D printing in dentistry [J].
Dawood, A. ;
Marti, B. Marti ;
Sauret-Jackson, V. ;
Darwood, A. .
BRITISH DENTAL JOURNAL, 2015, 219 (11) :521-529
[7]  
Fransson B, 1985, Dent Mater, V1, P197, DOI 10.1016/S0109-5641(85)80019-1
[8]  
Hoang LN, 2015, J PROSTHET DENT, V113, P398, DOI 10.1016/j.prosdent.2014.11.004
[9]   CONSIDERATIONS IN MEASUREMENT OF MARGINAL FIT [J].
HOLMES, JR ;
BAYNE, SC ;
HOLLAND, GA ;
SULIK, WD .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (04) :405-408
[10]   The Evaluation of Working Casts Prepared from Digital Impressions [J].
Hwang, Y. C. ;
Park, Y. S. ;
Kim, H. K. ;
Hong, Y. S. ;
Ahn, J. S. ;
Ryu, J. J. .
OPERATIVE DENTISTRY, 2013, 38 (06) :655-662