Effect of temperature on the cure shrinkage measurement of non-conductive adhesives for flip chip interconnects

被引:18
作者
Yu, H [1 ]
Mhaisalkar, SG
Wong, EH
机构
[1] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore 639798, Singapore
[2] MicroSyst, Modules & Components Lab, Inst Microelect, Singapore 117685, Singapore
关键词
D O I
10.1557/JMR.2005.0159
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Non-conductive adhesive (NCA) flip chip interconnects are emerging as attractive alternatives to lead or lead-free solder interconnects due to their environmental friendliness, lower processing temperatures, and extendability to fine pitch applications. The electrical connectivity of a NCA interconnect relies solely on the pure mechanical contact between the integrated circuit bump and the substrate pad; the electrical conductivity of the contact depends on the mechanical contact pressure, which in turns depends to a large extend on cure shrinkage characteristic of the NCA. In addition, to reduce the cost and increase the output, NCA is usually ramped up to 200 degrees C and cured for 1 min during the assembly process. However, fast cure reaction poses a great challenge for the accurate measurement of cure shrinkage. In this paper, to precisely determine the cure shrinkage at high temperature, cure shrinkage was first measured at lower temperatures with slow reaction rate by means of thermomechanical analyzer and then extrapolated to high temperatures. With the increase of cure temperature, the maximum of degree of cure will increase, but the maximum cure shrinkage reduces due to the expansion of materials at higher cure temperature. Furthermore, the slopes of the linear relationship between the cure shrinkage and the degree of cure at different cure temperatures after gelation were found to be similar and independent of the cure temperature. The cure shrinkage from gel-point to complete curing was determined to be 4.275%.
引用
收藏
页码:1324 / 1329
页数:6
相关论文
共 16 条
[1]   Contraction stress related to degree of conversion and reaction kinetics [J].
Braga, RR ;
Ferracane, JL .
JOURNAL OF DENTAL RESEARCH, 2002, 81 (02) :114-118
[2]   Prediction of moisture induced failures in flip chip on flex interconnections with non-conductive adhesives [J].
Caers, JFJM ;
Zhao, XJ .
53RD ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, 2003 PROCEEDINGS, 2003, :1176-1180
[3]   A simple method for the measurement of polymerization shrinkage in dental composites [J].
Cook, WD ;
Forrest, M ;
Goodwin, AA .
DENTAL MATERIALS, 1999, 15 (06) :447-449
[4]   Polymerization shrinkage of microfilled composites determined by laser beam scanning [J].
Fano, V ;
Ortalli, I ;
Pizzi, S ;
Bonanini, M .
BIOMATERIALS, 1997, 18 (06) :467-470
[5]   Characterization and modeling of static and cyclic relaxation in nonconductive adhesives [J].
Gunawan, M ;
Wong, EH ;
Mhaisalkar, SG ;
Davila, LT ;
Hong, Y ;
Caers, JFJM ;
Tsai, TK .
JOURNAL OF ELECTRONIC MATERIALS, 2004, 33 (09) :1041-1047
[6]   A study on the volumetric expansion of benzoxazine-based phenolic resin [J].
Ishida, H ;
Low, HY .
MACROMOLECULES, 1997, 30 (04) :1099-1106
[7]   Fundamental understanding of ACF conduction establishment with emphasis on the thermal and mechanical analysis [J].
Kwon, WS ;
Paik, KW .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2004, 24 (02) :135-142
[8]   MEASURING POLYMERIZATION SHRINKAGE OF PHOTO-ACTIVATED RESTORATIVE MATERIALS BY A WATER-FILLED DILATOMETER [J].
LAI, JH ;
JOHNSON, AE .
DENTAL MATERIALS, 1993, 9 (02) :139-143
[9]  
Li C, 2004, COMPOS SCI TECHNOL, V64, P55, DOI 10.1016/S0566-3538(03)00199-4
[10]   Recent advances in conductive adhesives for direct chip attach applications [J].
Liu, J .
MICROSYSTEM TECHNOLOGIES, 1998, 5 (02) :72-80