Characteristics of radon and its progeny concentrations in air-conditioned office buildings in Tokyo

被引:25
|
作者
Tokonami, S
Furukawa, M
Shicchi, Y
Sanada, T
Yamada, Y
机构
[1] Natl Inst Radiol Sci, Res Ctr Radiat Safety, Radon Res Grp, Chiba 2638555, Japan
[2] Japan Chem Anal Ctr, Chiba 2630002, Japan
关键词
D O I
10.1093/oxfordjournals.rpd.a006338
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A series of measurements were carried out to understand the characteristics of radon and its progeny in air-conditioned office buildings. Long-term measurements of radon were made with etched track detectors. Continuous measurements of radon and its progeny concentrations were also conducted in some buildings to study their temporal variations. The results show that radon and its progeny concentrations routinely varied along with the working activities. They are generally low while people are working. due to air conditioning, whereas they rise steadily after the air conditioning stops. When considering action levels not only in homes but also workplaces. attention should be paid to annual doses from the viewpoint of radiation protection. The annual dose is generally estimated with a long-term measurement of radon concentration using a passive device such as an etched track detector. Since its reading corresponds to a long-term average concentration regardless of working hours, but, the annual dose will be overestimated. When comparing a real dose after considering the working hours, they differ by a factor of more than 2.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [11] ENERGY REQUIREMENT OF AIR-CONDITIONED BUILDINGS
    ROUVEL, L
    BRENNSTOFF-WARME-KRAFT, 1973, 25 (11): : 442 - 447
  • [12] Particle concentrations and sizes in an air-conditioned office with normal efficiency air filtration of University
    Fan, Yuesheng
    Si, Pengfei
    Li, Angui
    Bai, Bao
    Zhao, Xiangwei
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [13] Impact of Window's Height on Energy Efficiency in Air-Conditioned Office Buildings
    Al-Ashwal, Najib Taher
    Hassan, Ahmad Sanusi
    ADVANCED SCIENCE LETTERS, 2017, 23 (11) : 11540 - 11544
  • [14] OPTIMUM DESIGN OF AIR-CONDITIONED BUILDINGS
    GUPTA, BD
    RAO, SS
    JOURNAL OF MECHANICAL DESIGN-TRANSACTIONS OF THE ASME, 1980, 102 (03): : 476 - 480
  • [15] Regression analysis of high-rise fully air-conditioned office buildings
    Lam, JC
    Hui, SCM
    Chan, ALS
    ENERGY AND BUILDINGS, 1997, 26 (02) : 189 - 197
  • [16] Radon and its decay products in an air-conditioned auditorium in correlation with indoor air parameters
    Polednik, Bernard
    Kozak, Krzysztof
    Mazur, Jadwiga
    Dudzinska, Marzenna
    Grzadziel, Dominik
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (05) : 621 - 630
  • [17] An analysis of electricity end-use in air-conditioned office buildings in Hong Kong
    Lam, JC
    Li, DHW
    Cheung, SO
    BUILDING AND ENVIRONMENT, 2003, 38 (03) : 493 - 498
  • [18] CONSISTENT PATTERN OF ELEVATED SYMPTOMS IN AIR-CONDITIONED OFFICE BUILDINGS - A REANALYSIS OF EPIDEMIOLOGIC STUDIES
    MENDELL, MJ
    SMITH, AH
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (10) : 1193 - 1199
  • [19] Multiple regression models for energy use in air-conditioned office buildings in different climates
    Lam, Joseph C.
    Wan, Kevin K. W.
    Liu, Dalong
    Tsang, C. L.
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) : 2692 - 2697
  • [20] A study on the identification and quantification of sources of VOCs in 5 air-conditioned Singapore office buildings
    Zuraimi, MS
    Tham, KW
    Sekhar, SC
    BUILDING AND ENVIRONMENT, 2004, 39 (02) : 165 - 177