Comparison of the modification of graphite electrodes with poly(4-aminobenzoic acid) and poly(4-hydroxyphenylacetic acid) for determination of Pb(II)

被引:3
|
作者
Matos, Marina F. F. [1 ]
Soares, Priscila, I [1 ]
Lima, Thais M. [1 ]
Pereira, Arnaldo C. [2 ]
Franco, Diego L. [3 ]
Ferreira, Lucas F. [1 ]
机构
[1] Fed Univ Jequitinhonha & Mucuri Valleys, Inst Sci & Technol, UFVJM, BR-39100000 Diamantina, MG, Brazil
[2] Univ Fed Sao Joao del Rei, Dept Nat Sci, UFSJ, BR-36307352 Sao Joao Del Rei, MG, Brazil
[3] Univ Fed Uberlandia, Inst Chem, UFU, BR-38700128 Patos De Minas, MG, Brazil
关键词
Modified electrodes; Electrochemical detection; poly(4-aminobenzoic acid); Polymeric films; Lead; Square-wave anodic stripping voltammetry; ANODIC-STRIPPING VOLTAMMETRY; GRAPHENE OXIDE; ELECTROCHEMICAL DETECTION; METAL-IONS; LEAD; NANOMATERIALS; SENSOR; WATER; NANOPARTICLES; CADMIUM(II);
D O I
10.1007/s11696-022-02282-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, we investigate and characterize graphite electrodes (GE) modified with polymeric films derived from 4-hydroxyphenylacetic acid (4-HPA) and 4-aminobenzoic acid (4-ABA) for the determination of the Pb(II) in water samples by square-wave anodic stripping voltammetry (SWASV). The electropolymerization was carried out in acid and basic medium using cyclic voltammetry (CV). The platform with poly(4-ABA) showed higher sensitivity for Pb(II) detection. Then, we performed the optimization of the electropolymerization parameters of 4-ABA where the better electrochemical responses were obtained at a monomer concentration of 0.25 mM with 25 cycles at 25 mV s(-1) in the basic media. The modified electrodes showed a decrease in the CV response in a ferricyanide/ferrocyanide potassium solution, and an increase in the charge transfer resistance (R-ct) values is obtained by impedance spectroscopy electrochemistry (EIS). The calibration curve obtained for Pb(II) detection showed a linear range from 50 to 3224 mu g L-1, with a limit of detection of 13.7 mu g L-1 and a limit of quantification of 45.6 mu g L-1. Addition and recovery studies showed levels of 94.5%. No detectable levels of Pb(II) under the established conditions were observed in water samples. Therefore, the investigated sensor using poly(4-ABA) is promising for Pb(II) detection in water samples. [GRAPHICS] .
引用
收藏
页码:5691 / 5704
页数:14
相关论文
共 50 条
  • [21] CATABOLISM OF 3-HYDROXYPHENYLACETIC AND 4-HYDROXYPHENYLACETIC ACID BY KLEBSIELLA-PNEUMONIAE
    MARTIN, M
    GIBELLO, A
    FERNANDEZ, J
    FERRER, E
    GARRIDOPERTIERRA, A
    JOURNAL OF GENERAL MICROBIOLOGY, 1991, 137 : 621 - 628
  • [22] New approach to immobilization and specific-sequence detection of nucleic acids based on poly(4-hydroxyphenylacetic acid)
    Silva, Tatiana A. R.
    Ferreira, Lucas F.
    Souza, Leticia M.
    Goulart, Luiz R.
    Madurro, Joao M.
    Brito-Madurro, Ana G.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (02): : 539 - 545
  • [23] WHISKER .11. POLY(ESTER-AMIDE)S DERIVED FROM VANILLIC ACID AND 4-AMINOBENZOIC ACID
    KRICHELDORF, HR
    LOHDEN, G
    POLYMER, 1995, 36 (08) : 1697 - 1705
  • [24] LC-poly(ester-amide-imide)s derived from trimellitic acid and 4-aminobenzoic acid
    Reinecke, H
    delaCampa, JG
    deAbajo, J
    Kricheldorf, HR
    Schwarz, G
    POLYMER, 1996, 37 (14) : 3101 - 3109
  • [25] Flow injection spectrophotometric determination of propoxur with diazotized 4-aminobenzoic acid
    Zanella, R
    Primel, EG
    Kurz, MHS
    Gonçalves, FF
    ANALYTICAL LETTERS, 2002, 35 (06) : 1095 - 1105
  • [26] A bacterial platform for the production of 4-hydroxyphenylacetic acid and its derivatives
    Cheng, Yiyuan
    Lu, Liangyu
    Hu, Chenyu
    Xue, Bingqing
    Wang, Xiaolei
    Zhang, Wen
    Wang, Tong
    Shen, Xiaolin
    Sun, Xinxiao
    Wang, Jia
    Yuan, Qipeng
    BIORESOURCE TECHNOLOGY, 2025, 422
  • [27] 4-Aminobenzoic acid-nicotinic acid (2/1)
    Jebas, Samuel Robinson
    Balasubramanian, Thailampillai
    ACTA CRYSTALLOGRAPHICA SECTION E-CRYSTALLOGRAPHIC COMMUNICATIONS, 2006, 62 : O5621 - O5622
  • [28] Growth and characterization of an adduct 4-aminobenzoic acid with nicotinic acid
    Anandhi, S.
    Rajalakshmi, M.
    Shyju, T. S.
    Gopalakrishnan, R.
    JOURNAL OF CRYSTAL GROWTH, 2011, 318 (01) : 774 - 779
  • [29] Electrochemical behavior and voltammetric determination of acetaminophen based on glassy carbon electrodes modified with poly(4-aminobenzoic acid)/electrochemically reduced graphene oxide composite films
    Zhu, Wencai
    Huang, Hui
    Gao, Xiaochun
    Ma, Houyi
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 : 21 - 28
  • [30] Synthesis and evaluation of 4-hydroxyphenylacetic acid amides and 4-hydroxycinnamamides as antioxidants
    Jung, YS
    Kang, TS
    Yoon, JH
    Joe, BY
    Lim, HJ
    Seong, CM
    Park, WK
    Kong, JY
    Cho, J
    Park, NS
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2002, 12 (18) : 2599 - 2602