Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study

被引:5
作者
Bredow, Jan [1 ]
Meyer, Carolin [1 ]
Scheyerer, Max Joseph [1 ]
Siedek, Florian [2 ]
Mueller, Lars Peter [1 ]
Eysel, Peer [1 ]
Stein, Gregor [1 ]
机构
[1] Univ Hosp Cologne, Dept Orthoped & Trauma Surg, Kerpener Str 62, D-50937 Cologne, Germany
[2] Univ Hosp Cologne, Dept Radiol, D-50937 Cologne, Germany
关键词
Anterior transpedicular screws; Navigated screw insertion; Accuracy of screw insertion; Spine surgery; PEDICLE SCREW; CLINICAL ARTICLE; FIXATION; PLACEMENT; COMPLICATIONS; STRENGTH; FUSION;
D O I
10.1007/s00586-016-4403-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The technique of pedicle screw stabilization is finding increasing popularity for use in the cervical spine. Implementing anterior transpedicular screws (ATPS) in cervical spine offers theoretical advantages compared to posterior stabilization. The goal of the current study was the development of a new setting for navigated insertion of ATPS, combining the advantage of reduced invasiveness of an anterior approach with the technical advantages of navigation. 20 screws were implanted in levels C3 to C6 of four cervical spine models (SAWBONES(A (R)) Cervical Vertebrae with Anterior Ligament) with the use of 3D fluoroscopy navigation system [Arcadis Orbic 3D, Siemens and VectorVision fluoro 3D trauma software (BrainLAB)]. The accuracy of inserted screws was analyzed according to postoperative CT scans and following the modified Gertzbein and Robbins classification. 20 anterior pedicle screws were placed in four human cervical spine models. Of these, eight screws were placed in C3, two screws in C4, six screws in C5, and four screws in C6. 16 of 20 screws (80 %) reached a grade 1 level of accuracy according to the modified Gertzbein and Robbins Classification. Three screws (15 %) were grade 2, and one screw (5 %) was grade 3. Grade 4 and 5 positions were not evident. Summing grades 1 and 2 together as "good" positions, 95 % of the screws achieved this level. Only a single screw did not fulfill these criteria. The setting introduced in this study for navigated insertion of ATPS into cervical spine bone models is well implemented and shows excellent results, with an accuracy of 95 % (Gertzbein and Robbins grade 2 or better). Thus, this preliminary study represents a prelude to larger studies with larger case numbers on human specimens.
引用
收藏
页码:1683 / 1689
页数:7
相关论文
共 32 条
[1]   Anterior pedicle screw fixation for multilevel cervical corpectomy and spinal fusion [J].
Aramomi, M. ;
Masaki, Y. ;
Koshizuka, S. ;
Kadota, R. ;
Okawa, A. ;
Koda, M. ;
Yamazaki, M. .
ACTA NEUROCHIRURGICA, 2008, 150 (06) :575-582
[2]   Biomechanical Pullout Strength and Stability of the Cervical Artificial Pedicle Screw [J].
Barnes, Alison H. ;
Eguizabal, Johnny A. ;
Acosta, Frank L., Jr. ;
Lotz, Jeffrey C. ;
Buckley, Jenni M. ;
Ames, Christopher P. .
SPINE, 2009, 34 (01) :E16-E20
[3]   Transarticular screw fixation C1/C2 in traumatic atlantoaxial instabilities. Comparison between percutaneous and open procedures [J].
Blauth, M ;
Richter, M ;
Lange, U .
ORTHOPADE, 1999, 28 (08) :651-661
[4]   The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine [J].
Bredow, J. ;
Oppermann, J. ;
Kraus, B. ;
Schiller, P. ;
Schiffer, G. ;
Sobottke, R. ;
Eysel, P. ;
Koy, T. .
EUROPEAN SPINE JOURNAL, 2015, 24 (12) :2967-2976
[5]   Biomechanical comparison of inside-outside screws, cables, and regular screws, using a sawbone model [J].
Caglar, YS ;
Torun, F ;
Pait, TG ;
Hogue, W ;
Bozkurt, M ;
Özgen, S .
NEUROSURGICAL REVIEW, 2005, 28 (01) :53-58
[7]   Load sharing properties of cervical pedicle screw-rod constructs versus lateral mass screw-rod constructs [J].
Dunlap, Bradley J. ;
Karaikovic, Eldin E. ;
Park, Hyung-Soon ;
Sokolowski, Mark J. ;
Zhang, Li-Qun .
EUROPEAN SPINE JOURNAL, 2010, 19 (05) :803-808
[8]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[9]   Surgical training using three-dimensional simulation in placement of cervical lateral mass screws: a blinded randomized control trial [J].
Gottschalk, Michael B. ;
Yoon, S. Tim ;
Park, Daniel K. ;
Rhee, John M. ;
Mitchell, Phillip M. .
SPINE JOURNAL, 2015, 15 (01) :168-175
[10]   C1-c2 transarticular screw fixation: Technical aspects [J].
Haid, RW .
NEUROSURGERY, 2001, 49 (01) :71-74