Data harmonisation for energy system analysis-Example of multi-model experiments

被引:6
作者
Gardian, H. [1 ]
Beck, J. -p. [2 ]
Koch, M. [3 ]
Kunze, R. [4 ]
Muschner, C. [5 ]
Huelk, L. [5 ]
Bucksteeg, M. [6 ]
机构
[1] German Aerosp Ctr DLR, Inst Networked Energy Syst, Dept Energy Syst Anal, Curiestr 4, D-70563 Stuttgart, Germany
[2] Helmut Schmidt Univ, Univ Fed Armed Forces Hamburg, Inst Automation Technol, Holstenhofweg 85, D-22043 Hamburg, Germany
[3] Oeko Inst E V, Merzhauser Str 173, D-79100 Freiburg, Germany
[4] Energy Syst Anal Associates ESA 2, Bernhardstr 92, D-01187 Dresden, Germany
[5] Reiner Lemoine Inst RLI, Rudower Chaussee 12, D-12489 Berlin, Germany
[6] Univ Duisburg Essen, House Energy Markets & Finance, Univ Str 12, D-45117 Essen, Germany
关键词
Data harmonisation; Model comparison; Metadata; Energy system modelling; Energy system analysis;
D O I
10.1016/j.rser.2022.112472
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A variety of models have emerged in the field of energy system analysis to answer a wide range of research questions centred around a sustainable future for the energy sector. Even models designed to address similar issues often have a different focus or modelling approach. Thus, model experiments are a vital tool to provide an overview of the range of models and enable decision-makers to make meaningful model choices. Such comparisons are executed based on a harmonised data set to ensure a high degree of comparability. In the MODEX project cluster, six model experiments, including 40 energy system models, were conducted, and efforts were made to harmonise the input data within the individual comparison and beyond them in the consortium. The experiences and findings of the consortium on how data harmonisation could be performed are presented in this paper. In particular, the focus lies on data transparency to ensure a high degree of reproducibility. A key finding is that while model heterogeneity complicates harmonisation, an early focus on data research and scenario design promotes the creation of a common data set. The metadata collection can provide a significant advantage for the use of model experiment results by external scientists and the data acquisition process itself because of the predefined machine-readable and standardised format.
引用
收藏
页数:13
相关论文
共 49 条
  • [21] Challenges in the harmonisation of global integrated assessment models: A comprehensive methodology to reduce model response heterogeneity
    Giarola, Sara
    Mittal, Shivika
    Vielle, Marc
    Perdana, Sigit
    Campagnolo, Lorenza
    Delpiazzo, Elisa
    Ha Bui
    Kraavi, Annela Anger
    Kolpakov, Andrey
    Sognnaes, Ida
    Peters, Glen
    Hawkes, Adam
    Koberle, Alexandre C.
    Grant, Neil
    Gambhir, Ajay
    Nikas, Alexandros
    Doukas, Haris
    Moreno, Jorge
    van de Ven, Dirk-Jan
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 783
  • [22] Gils H.C., 2018, RegMex - Modellexperimente und -vergleiche zur Simulation von Wegen zu einer vollstandig regenerativen Energieversorgung
  • [23] Comparison of spatially and temporally resolved energy system models with a focus on Germany's future power supply
    Gils, Hans Christian
    Pregger, Thomas
    Flachsbarth, Franziska
    Jentsch, Mareike
    Dierstein, Constantin
    [J]. APPLIED ENERGY, 2019, 255
  • [24] Transparency, reproducibility, and quality of energy system analyses - A process to improve scientific work
    Huelk, Ludwig
    Mueller, Berit
    Glauer, Martin
    Forster, Elisa
    Schachler, Birgit
    [J]. ENERGY STRATEGY REVIEWS, 2018, 22 : 264 - 269
  • [25] Huntington HG, 2020, ENERGY POL, P144
  • [26] IIASA and the pyam developer team, 2021, PYAM AN VIS INT ASS
  • [27] A review of energy models
    Jebaraj, S.
    Iniyan, S.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2006, 10 (04) : 281 - 311
  • [28] Jlich Projekttrager Jlich GmbH Forschungszentrum, MODELL EXPERIMENTE F
  • [29] Kriegler E., 2014, ASSESSING PATHWAYS A
  • [30] Kunze R., 2021, FUTURE EUROPEAN ENER, P27, DOI [10.1007/978-3-030-60914-6_3, DOI 10.1007/978-3-030-60914-6_3]