Experimental and analytical study on CFRP strips-to-concrete bonded joints using EBROG method

被引:56
作者
Moshiri, Niloufar [1 ,2 ]
Tajmir-Riahi, Amir [1 ]
Mostofinejad, Davood [1 ]
Czaderski, Christoph [2 ]
Motavalli, Masoud [2 ,3 ]
机构
[1] IUT, Esfahan, Iran
[2] Swiss Fed Labs Mat Sci & Technol Empa, Uberlandstr 129, CH-8600 Dubendorf, Switzerland
[3] Univ Tehran, Tehran, Iran
基金
美国国家科学基金会;
关键词
EBROG; Externally bonded reinforcement on grooves; CFRP strip; Single lap-shear test; Bond-slip behavior; DIC; FRP SHEETS; BEHAVIOR; STRENGTH; ANCHORAGE; MODELS; LAW;
D O I
10.1016/j.compositesb.2018.09.046
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Retrofitting of reinforced concrete (RC) members with fiber reinforced polymers (FRPs) by means of Externally Bonded Reinforcement On Groove (EBROG) method was confirmed as a brilliant substitute to conventional method of externally bonded reinforcement (EBR). However, efficiency of EBROG method on improving bond properties of pre-cured strips with high fiber content and high load carrying capacity has not been studied before. In this research, a set of 10 single lap-shear tests were carried out to assess the behavior of FRP-to-concrete bonded joints. Pre-cured CFRP strips were bonded to concrete using EBR and EBROG methods. Full-field displacement measurements were carried out through a 2D digital image correlation system, DIC. All tests were carried out at the Isfahan University of Technology in Iran. In addition, analytical modeling was conducted for the first time to obtain bond shear stress-slip behavior for EBROG methods. Based on experimental results, bond resistance in EBROG system increased considerably compared to EBR. For instance, EBROG method with two 5 x 5 mm (width x depth) grooves led to more than 90% increase in bond capacity, in comparison to EBR method. Furthermore, debonding in concrete substrate was eliminated when EBROG method was used. Cohesion failure in adhesive accompanied with FRP delamination was observed as the dominant failure mode. Analytical results revealed that bond shear stress resistance increased in EBROG joints compared to EBR ones. Moreover, the effective bond length increased in EBROG method when CFRP strips were utilized. Interfacial shear stresses, therefore, transferred to the concrete substrate through a larger bond area. So, the specimen resisted higher anchorage load and larger slip, and debonding was postponed.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 41 条
[1]  
[Anonymous], 2000, Standard Test Methods for Apparent Porosity, Water Absorption, Apparent Specific Gravity, and Bulk Density of Burned Refractory Brick and Shapes by Boiling Water (ASTM C20-00)
[2]  
[Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
[3]  
[Anonymous], 2001, FIB B, V14
[4]   A fully-analytical approach for modelling the response of FRP plates bonded to a brittle substrate [J].
Caggiano, Antonio ;
Martinelli, Enzo ;
Faella, Ciro .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2012, 49 (17) :2291-2300
[5]  
Canadian Standard Association (CSA), 2002, 80602 CSA
[6]   Direct determination of cohesive stress transfer during debonding of FRP from concrete [J].
Carloni, Christian ;
Subramaniam, Kolluru V. .
COMPOSITE STRUCTURES, 2010, 93 (01) :184-192
[7]   Anchorage strength models for FRP and steel plates bonded to concrete [J].
Chen, JF ;
Teng, JG .
JOURNAL OF STRUCTURAL ENGINEERING, 2001, 127 (07) :784-791
[8]   An analytical cohesive crack modeling approach to the edge debonding failure of FRP-plated beams [J].
Cornetti, Pietro ;
Corrado, Mauro ;
De Lorenzis, Laura ;
Carpinteri, Alberto .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2015, 53 :92-106
[9]  
Czaderski C., 2012, THESIS
[10]   Front and Side View Image Correlation Measurements on FRP to Concrete Pull-Off Bond Tests [J].
Czaderski, Christoph ;
Soudki, Khaled ;
Motavalli, Masoud .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (04) :451-463