Effects of Ankaferd Hemostat on red blood cell aggregation: a hemorheological study

被引:6
|
作者
Ciftciler, Rafiye [1 ]
Aksu, Salih [1 ]
Dikmenoglu Falkmarken, Neslihan [2 ]
Celalettin Haznedaroglu, Ibrahim [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Hematol, Ankara, Turkey
[2] Hacettepe Univ, Fac Med, Dept Physiol, Ankara, Turkey
关键词
Ankaferd Hemostat; erythrocyte aggregation; hemorheology; ANALYZER LORCA; IRON;
D O I
10.3906/sag-1808-60
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/aim: Ankaferd hemostat (ABS; Ankaferd blood stopper, Istanbul, Turkey) is a prohemostatic agent affecting erythrocytes. The hemostatic action of ABS depends upon fibrinogen gamma chain, prothrombin, and red blood cells. The aim of this study was to assess the effects of ABS on erythrocyte aggregation via hemorheological analyses. Materials and methods: To measure erythrocyte aggregation, blood samples were obtained from healthy, nonsmoker volunteers who had not taken any medication in the previous 10 days. One mL of blood was placed into the laser-assisted optical rotational cell analyzer (LORCA), into the chamber formed by the gap between two concentric glass cylinders. The solution prepared with ABS and saline was added to blood in incremental amounts of 10 mu L, 20 mu L, 30 mu L, 40 mu L, 50 mu L, 60 mu L, 70 mu L, and 100 mu L. Erythrocyte aggregation was determined by laser-assisted optical rotational cell analyzer at 37 degrees C. Results: AMP was found to be 17.7 +/- 2.1 au in the blood without ABS, whereas it was lower in the blood with ABS. AMP was 16.0 +/- 3.3 in the ABS-added blood group. RBC aggregates did not form faster when cells contacted ABS. The t t1/2 value was 4.6 +/- 2.6 in the ABS-added blood group and 1.9 +/- 0.20 in the control group. Aggregation was faster in the control group (P = 0.03). AI, which is a combination of AMP and t1/2, was lowered in the ABS group (48.7 +/- 12.3) compared to the control group (65.8 +/- 1.6) (P = 0.02). It was notable that the gamma Isc max (sec(-1)) value of the control was higher (200 +/- 106) than the ABS-added blood group (141 +/- 51.0). Conclusion: ABS has antierythroid aggregation effect. ABS inhibits pathological aggregation of red blood cells. Antithrombotic clinical effects of ABS may be ascribed to the antierythroid aggregan actions of the drug.
引用
收藏
页码:356 / 360
页数:5
相关论文
共 50 条
  • [21] Comparison of three instruments for measuring red blood cell aggregation
    Baskurt, Oguz K.
    Uyuklu, Mehmet
    Ulker, Pinar
    Cengiz, Melike
    Nemeth, Norbert
    Alexy, Tamas
    Shin, Sehyun
    Hardeman, Max R.
    Meiselman, Herbert J.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 43 (04) : 283 - 298
  • [22] Detection and characterization of red blood cell (RBC) aggregation with photoacoustics
    Hysi, Eno
    Saha, Ratan K.
    Rui, Min
    Kolios, Michael C.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [23] A Particle Dynamic Model of Red Blood Cell Aggregation Kinetics
    Marianne Fenech
    Damien Garcia
    Herbert J. Meiselman
    Guy Cloutier
    Annals of Biomedical Engineering, 2009, 37 : 2299 - 2309
  • [24] Measurement of red blood cell aggregation in disposable capillary tubes
    Baskurt, Oguz K.
    Uyuklu, Mehmet
    Ozdem, Sebahat
    Meiselman, Herbert J.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 47 (04) : 295 - 305
  • [25] Simultaneous Photoacoustic Detection of Red Blood Cell Aggregation and Oxygenation
    Hysi, Eno
    Saha, Ratan K.
    Kolios, Michael C.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1398 - 1401
  • [26] Design of a Microfluidic System for Red Blood Cell Aggregation Investigation
    Mehri, R.
    Mavriplis, C.
    Fenech, M.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (06):
  • [27] A Particle Dynamic Model of Red Blood Cell Aggregation Kinetics
    Fenech, Marianne
    Garcia, Damien
    Meiselman, Herbert J.
    Cloutier, Guy
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (11) : 2299 - 2309
  • [28] Examination of the relation between red blood cell aggregation and hematocrit in human and various experimental animals
    Barath, Barbara
    Somogyi, Viktoria
    Tanczos, Bence
    Varga, Adam
    Bereczky, Zsuzsanna
    Nemeth, Norbert
    Deak, Adam
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 78 (02) : 187 - 198
  • [29] Effect of whole-body cryotherapy treatments on blood morphology and blood rheology: red blood cell deformability, red blood cell aggregation in healthy subjects
    Ptaszek, Bartlomiej
    Podsiadlo, Szymon
    Teleglow, Aneta
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2023, 83 (03) : 279 - 286
  • [30] Influence of red blood cell aggregation on perfusion of an artificial microvascular network
    Reinhart, Walter H.
    Piety, Nathaniel Z.
    Shevkoplyas, Sergey S.
    MICROCIRCULATION, 2017, 24 (05)