Digital differential interference contrast autofocus for high-resolution oil-immersion microscopy

被引:6
作者
Shen, Feilmo [1 ,2 ]
Hodgson, Louis [1 ,2 ]
Price, Jeffrey H. [3 ,4 ]
Hahn, Klaus M. [1 ,2 ]
机构
[1] Univ N Carolina, Dept Pharmacol, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Lineberger Canc Ctr, Chapel Hill, NC 27599 USA
[3] Burnham Inst Med Res, La Jolla, CA 92037 USA
[4] Vala Sci Inc, San Diego, CA 92121 USA
关键词
autofocus; image cytometry; lab automation; differential interference contrast; modulation transfer function;
D O I
10.1002/cyto.a.20558
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Continued advances in cellular fluorescent biosensors enable studying intracellular protein dynamics in individual, living cells. Autofocus is valuable in such studies to compensate for temperature drift, uneven substrate over multiple fields of view, and cell growth during long-term high-resolution time-lapse studies of hours to days. Observing cellular dynamics with the highest possible resolution and sensitivity motivates the use of high numerical aperture (NA) oil-immersion objectives, and control of fluorescence exposure to minimize phototoxicity. To limit phototoxicity, to maximize light throughput of the objective for biosensor studies, and because phase contrast is distorted by the meniscus in microtiter plates, we studied autofocus in differential interference contrast (DIC) microscopy with a 60X 1.45 NA oil objective after removing the analyzer from the fluorescent light path. Based on a study of the experimental DIC modulation transfer function, we designed a new bandpass digital filter for measuring image sharpness. Repeated tests of DIC autofocus with this digital filter on 225 fields-of-view resulted in a precision of 8.6 nm (standard deviation). Autofocus trials on specimens with thicknesses from 9.47 to 33.20 mu m, controlled by cell plating density, showed that autofocus precision was independent of specimen thickness. The results demonstrated that the selected spatial frequencies enabled very high-precision autofocus for high NA DIC automated microscopy, thereby potentially removing the problems of meniscus distortion in phase contrast imaging of microtiter plates and rendering the toxicity of additional fluorescence exposure unnecessary. (c) 2008 International Society for Advancement of Cytometry.
引用
收藏
页码:658 / 666
页数:9
相关论文
共 16 条
[1]   The spatial variation of the refractive index in biological cells [J].
Beuthan, J ;
Minet, O ;
Helfmann, J ;
Herrig, M ;
Muller, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03) :369-382
[2]  
Born M., 1973, Principles of Optics
[3]   High-performance autofocus circuit for biological microscopy [J].
Bravo-Zanoguera, M ;
Von Massenbach, B ;
Kellner, AL ;
Price, JH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) :3966-3977
[4]  
GAITS F, 2003, SCI STKE, V165, P3
[5]   A COMPARISON OF DIFFERENT FOCUS FUNCTIONS FOR USE IN AUTOFOCUS ALGORITHMS [J].
GROEN, FCA ;
YOUNG, IT ;
LIGTHART, G .
CYTOMETRY, 1985, 6 (02) :81-91
[6]   AUTOMATIC ANALYSIS OF BLOOD CELLS [J].
INGRAM, M ;
PRESTON, K .
SCIENTIFIC AMERICAN, 1970, 223 (05) :72-&
[7]  
Inoue S., 1997, Video Microscopy: The Fundamentals, V2nd
[8]  
JARVIS RA, 1976, MICROSCOPE, V24, P163
[9]   Shining light on signaling and metabolic networks by genetically encoded biosensors [J].
Lalonde, S ;
Ehrhardt, DW ;
Frommer, WB .
CURRENT OPINION IN PLANT BIOLOGY, 2005, 8 (06) :574-581
[10]   STRUCTURAL ORGANIZATION OF INTERPHASE 3T3-FIBROBLASTS STUDIED BY TOTAL INTERNAL-REFLECTION FLUORESCENCE MICROSCOPY [J].
LANNI, F ;
WAGGONER, AS ;
TAYLOR, DL .
JOURNAL OF CELL BIOLOGY, 1985, 100 (04) :1091-1102