Effect of long-term repeated deflections on fatigue of preloaded superelastic nickel-titanium archwires

被引:16
作者
van Aken, Cornelis A. J. M. [2 ]
Pallav, Prem [1 ]
Kleverlaan, Cornelis J.
Kuitert, Reinder B.
Prahl-Andersen, Birte
Feilzer, Albert J.
机构
[1] Vrije Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Dent Mat Sci, NL-1066 EA Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Orthodont, Amsterdam, Netherlands
关键词
D O I
10.1016/j.ajodo.2005.10.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this in-vitro study was to investigate the changes in force delivery of superelastic nickel-titanium archwires used in combination with a self-ligating bracket system after dynamic fatigue-loading in a 3-bracket model under controlled temperature. Methods: Samples of 2 superelastic nickeltitanium (active austenitic) wires, a conventional nickel-titanium wire, and a stainless steel wire, all 0.014- in round, were divided into 2 groups: static deflection and dynamic deflection. The static specimens were under a constant deflection of 3.0 mm. The dynamic specimens had the same constant deflection of 3.0 mm but were subjected to additional repeated deflections of 0.5 mm, applied by a fatigue tester. The test situation simulates a patient's archwire under deflection and subjected to occlusal contact during 1, 100, 10,000, and 100,000 cycles. Fatigue changes were assessed with a 3-point bending test. Results: Type of wire, loading or unloading, and number of cycles as within-subject factors were statistically significantly different. No statistically significant difference between the test condition, static vs dynamic, was found. The repeated deflections of 0.5 mm were not enough to induce an extra effect of fatigue. Conclusions: Occlusal forces transferred to a considerably deflected archwire, such as in the large malalignments in the early stages of orthodontic treatment, will have no fatigue effect on the unloading force of that archwire.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 28 条
[1]   EVALUATION OF COBALT-SUBSTITUTED NITINOL WIRE IN ORTHODONTICS [J].
ANDREASEN, GF ;
BARRETT, RD .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1973, 63 (05) :462-470
[2]  
ANDREASEN GF, 1978, AM J ORTHOD DENTOFAC, V73, P141, DOI 10.1016/0002-9416(78)90184-7
[3]  
Bolhuis HPB, 2004, INT J PROSTHODONT, V17, P571
[4]   Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry [J].
Bourauel, C ;
Fries, T ;
Drescher, D ;
Plietsch, R .
EUROPEAN JOURNAL OF ORTHODONTICS, 1998, 20 (01) :79-92
[5]   CHINESE NITI WIRE - A NEW ORTHODONTIC ALLOY [J].
BURSTONE, CJ ;
BAI, Q ;
MORTON, JY .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1985, 87 (06) :445-452
[6]  
Drescher D, 1994, Schweiz Monatsschr Zahnmed, V104, P578
[7]   On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility [J].
Es-Souni, M ;
Es-Souni, M ;
Fischer-Brandies, H .
BIOMATERIALS, 2002, 23 (14) :2887-2894
[8]  
Evans T J, 1996, Br J Orthod, V23, P269
[9]   Clinical comparison and performance perspective of three aligning arch wires [J].
Evans, TJW ;
Jones, ML ;
Newcombe, RG .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 114 (01) :32-39
[10]   Cyclic deformation mechanisms in precipitated NiTi shape memory alloys [J].
Gall, K ;
Maier, H .
ACTA MATERIALIA, 2002, 50 (18) :4643-4657