Bubble breakup in co-current upward flowing liquid using honeycomb monolith breaker

被引:19
作者
Gadallah, Aly H. [1 ,2 ]
Siddiqui, Kamran [2 ]
机构
[1] Tanta Univ, Fac Engn, Dept Power Mech Engn, Tanta 31521, Egypt
[2] Univ Western Ontario, Dept Mech & Mat Engn, London, ON N6A 5B9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Bubble breakup; Bubble column reactor; Honeycomb monolith breaker; Co-current flowing liquid; High speed imaging; INTERFACIAL AREA TRANSPORT; 3-PHASE FLUIDIZED-BEDS; PBM COUPLED MODEL; MASS-TRANSFER; COLUMN REACTORS; MULTIPHASE REACTORS; TURBULENT-FLOW; HEAT-TRANSFER; POROUS PLATE; GAS;
D O I
10.1016/j.ces.2015.03.028
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Bubble column reactors are used in industrial practices due to their intrinsic advantages of good mixing ability, high heat transfer and operational versatility. Generation of small bubbles in bubble column is a crucial step to improve their performance. The present investigation introduces a new approach for bubble breakup in an upward co-flowing liquid using a honeycomb monolith breaker with square cell structure. The experimental measurements were conducted using high speed imaging at different superficial liquid velocities and gas flow rates ranging between 8 to 50 cm/s and 165 to 1000 ml/min, respectively. A comparison between the bubbles generated from the monolith breaker and those generated from the nozzle shows that the monolith breaker reduces the bubble size by approximately 60% over the given range of liquid superficial velocities and gas Row rates. It is observed that at low superficial liquid velocities and low gas Row rates, the bubble size at the breaker exit follows log-normal distribution, which becomes more symmetric at higher superficial liquid velocities and gas Row rates. The main contributor of large bubbles formation at the monolith breaker exit is the bubbles' coalescence. Different mechanisms of bubbles coalescence at the breaker outlet are observed and classified into three types; multi- and successive ''accumulative" coalescence, multi- and non-successive coalescence, and bubbles coalescence in the vicinity of the breaker outlet. The efficiency of the breaker is quantified in terms of the fractional conversion of bubbles' kinetic energy into the surface energy. A strong dependency of the breaker efficiency on the superficial liquid velocity is observed. The results indicate that an optimal liquid velocity exists that corresponds to the minimal bubble coalescence at which the breaker efficiency is maximum. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:22 / 40
页数:19
相关论文
共 67 条
[1]   Gas holdup in trayed bubble column reactors [J].
Alvaré, J ;
Al-Dahhan, MH .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (09) :3320-3326
[2]   Liquid phase mixing in trayed bubble column reactors [J].
Alvaré, J ;
Al-Dahhan, MH .
CHEMICAL ENGINEERING SCIENCE, 2006, 61 (06) :1819-1835
[3]   On the breakup of fluid particles in turbulent flows [J].
Andersson, R ;
Andersson, B .
AICHE JOURNAL, 2006, 52 (06) :2020-2030
[4]   BUBBLE-SIZE DISTRIBUTIONS IN A MECHANICALLY AGITATED GAS-LIQUID CONTACTOR [J].
BARIGOU, M ;
GREAVES, M .
CHEMICAL ENGINEERING SCIENCE, 1992, 47 (08) :2009-2025
[5]   Mass transfer characteristics in a large-scale slurry bubble column reactor with organic liquid mixtures [J].
Behkish, A ;
Men, ZW ;
Inga, JR ;
Morsi, BI .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (16) :3307-3324
[6]   BUBBLES IN VISCOUS-LIQUIDS - SHAPES, WAKES AND VELOCITIES [J].
BHAGA, D ;
WEBER, ME .
JOURNAL OF FLUID MECHANICS, 1981, 105 (APR) :61-85
[7]   Bubble formation in a coflow configuration in normal and reduced gravity [J].
Bhunia, A ;
Pais, SC ;
Kamotani, Y ;
Kim, IH .
AICHE JOURNAL, 1998, 44 (07) :1499-1509
[8]  
CHAUDHARI RV, 1994, REV CHEM ENG, V10, P131
[9]   Theoretical analysis of bubble formation in a co-flowing liquid [J].
Chen, WB ;
Tan, RBH .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2002, 35 (10) :952-962
[10]   BUBBLE BREAKAGE MECHANISMS DUE TO COLLISION WITH A PARTICLE IN A LIQUID-MEDIUM [J].
CHEN, YM ;
FAN, LS .
CHEMICAL ENGINEERING SCIENCE, 1989, 44 (01) :117-132