Indoor climate in interior Alaska: simultaneous measurement of ventilation, benzene and toluene in residential indoor air of two homes

被引:17
作者
Isbell, MA [1 ]
Stolzberg, RJ [1 ]
Duffy, LK [1 ]
机构
[1] Univ Alaska Fairbanks, Dept Chem & Biochem, Fairbanks, AK 99775 USA
关键词
benzene; toluene; indoor air quality; Alaska; ventilation; subarctic;
D O I
10.1016/j.scitotenv.2004.11.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Benzene and toluene mixing ratios were measured in the indoor air of two subarctic homes during summer and winter. Benzene in the living area of these homes ranged from 1 to 25 ppbv and toluene ranged from 1 to 104 ppbv. Source strength estimate calculations supported the hypothesis that gasoline in the home's attached garage is the primary source of these compounds in living area air. These calculations demonstrated that the home with the air-to-air heat exchangers and forced ventilation had less transport of aromatics than the unventilated home. Perturbation experiment showed that a full metal gasoline can in the garage was consistent with the importance of the garage as a source for the concentration of aromatics in the air of the living spaces in these Alaskan homes. The type of ventilation system also had an important effect on the quality of air in the living area. (c) 2004 Published by Elsevier B.V.
引用
收藏
页码:31 / 40
页数:10
相关论文
共 22 条
[1]  
[Anonymous], FED REG
[2]   The spatial and temporal variations in PM10 mass from six UK homes [J].
BéruBé, KA ;
Sexton, KJ ;
Jones, TP ;
Moreno, T ;
Anderson, S ;
Richards, RJ .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 324 (1-3) :41-53
[3]  
Bolle R, 2000, Int J Circumpolar Health, V59, P228
[4]   DRIVER EXPOSURE TO VOLATILE ORGANIC-COMPOUNDS, CO, OZONE, AND NO2 UNDER DIFFERENT DRIVING CONDITIONS [J].
CHAN, CC ;
OZKAYNAK, H ;
SPENGLER, JD ;
SHELDON, L .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (05) :964-972
[5]  
Dietz RN., 1982, ENVIRON INT, V8, P419, DOI DOI 10.1016/0160-4120(82)90060-5
[6]  
DIETZ RN, 1985, 36327 BNL
[7]  
Dietz RN, 1986, MEASURED AIR LEAKAGE, P203
[8]   ERROR ANALYSIS TECHNIQUES FOR PERFLUOROCARBON TRACER DERIVED MULTIZONE VENTILATION RATES [J].
DOTTAVIO, TW ;
SENUM, GI ;
DIETZ, RN .
BUILDING AND ENVIRONMENT, 1988, 23 (03) :187-194
[9]   ASSESSMENT OF THE INFLUENCE OF CLIMATIC FACTORS ON CONCENTRATION LEVELS OF VOLATILE ORGANIC-COMPOUNDS (VOCS) IN CANADIAN HOMES [J].
FELLIN, P ;
OTSON, R .
ATMOSPHERIC ENVIRONMENT, 1994, 28 (22) :3581-3586
[10]   SOURCES AND SOURCE STRENGTHS OF VOLATILE ORGANIC-COMPOUNDS IN A NEW OFFICE BUILDING [J].
HODGSON, AT ;
DAISEY, JM ;
GROT, RA .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (11) :1461-1468