Test-retest reliability of the OptoGait system for the analysis of spatiotemporal running gait parameters and lower body stiffness in healthy adults

被引:12
作者
Jaen-Carrillo, Diego [1 ]
Garcia-Pinillos, Felipe [2 ]
Carton-Llorente, Antonio [1 ]
Almenar-Arasanz, Alejandro Jesus [3 ]
Bustillo-Pelayo, Jose Antonio [4 ]
Roche-Seruendo, Luis E. [1 ]
机构
[1] Univ San Jorge, Campus Univ,Autov A23 Km 299, Villanueva De Gallego 50830, Zaragoza, Spain
[2] Univ La Frontera, Dept Phys Educ Sports & Recreat, Temuco, Chile
[3] Podoact Dept Invest Podoact, Huesca, Spain
[4] Clin Omica, Zaragoza, Spain
关键词
Reliability; testing; OptoGait; running; stiffness; PHOTOELECTRIC-CELL SYSTEM; STRIDE FREQUENCY; MECHANICAL WORK; LOCOMOTION; LEG; ECONOMY; FATIGUE; MODEL; SIZE;
D O I
10.1177/1754337119898353
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Despite the widespread use of the OptoGait photoelectric cell system for the analysis of running spatiotemporal parameters, its reliability has not been proved. Consequently, this study intends to determine the test-retest reliability of the system when applied to treadmill running spatiotemporal parameters and lower body stiffness at a constant velocity. Amateur endurance runners (n = 31; age: 34.42 +/- 9.26 years; height: 171.54 +/- 9.15 cm; body mass: 66.63 +/- 11.3 kg) voluntarily consented to participate in this study. Data for each participant were recorded twice per session across two testing sessions. The intra-session and inter-session reliabilities of spatiotemporal parameters and lower body stiffness were determined through test-retest analysis. Although mean comparisons revealed significant differences between measurements in spatiotemporal running gait characteristics and lower body stiffness for intra-session (p < 0.05 in all parameters), the effect size was always small (<0.4). Moreover, the relationship between measurements was very large for spatiotemporal parameters and lower body stiffness (r > 0.7). The intraclass correlation coefficients revealed an almost perfect correlation between measurements (intraclass correlation coefficients >0.81), except Kleg with substantial reliability (intraclass correlation coefficient = 0.788). The inter-session reliability revealed some significant differences in contact time (p = 0.009) and Kleg (p = 0.013), although Cohen's d indicated small effect size (<0.31). The relationship between sessions was very large for spatiotemporal parameters and lower body stiffness (r > 0.8), and the intraclass correlation coefficients revealed an almost perfect inter-session association (intraclass correlation coefficients >0.881). The results found here show that the OptoGait system can be used confidently for running spatiotemporal parameters analysis and lower body stiffness at a constant velocity for healthy adults.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 37 条
  • [21] RELIABILITY OF THE OPTOJUMP NEXT SYSTEM FOR MEASURING TEMPORAL VALUES IN ELITE RACEWALKING
    Hanley, Brian
    Tucker, Catherine B.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (12) : 3438 - 3443
  • [22] CORONARY-ARTERY SIZE AND DILATING CAPACITY IN ULTRADISTANCE RUNNERS
    HASKELL, WL
    SIMS, C
    MYLL, J
    BORTZ, WM
    STGOAR, FG
    ALDERMAN, EL
    [J]. CIRCULATION, 1993, 87 (04) : 1076 - 1082
  • [23] Preferred and optimal stride frequency, stiffness and economy: changes with fatigue during a 1-h high-intensity run
    Hunter, Iain
    Smith, Gerald A.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2007, 100 (06) : 653 - 661
  • [24] A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research
    Koo, Terry K.
    Li, Mae Y.
    [J]. JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) : 155 - 163
  • [25] Familiarization to treadmill running in young unimpaired adults
    Lavcanska, V
    Taylor, NF
    Schache, AG
    [J]. HUMAN MOVEMENT SCIENCE, 2005, 24 (04) : 544 - 557
  • [26] Concurrent Validity and Test-retest Reliability of the OPTOGait Photoelectric Cell System for the Assessment of Spatio-temporal Parameters of the Gait of Young Adults
    Lee, Myung Mo
    Song, Chang Ho
    Lee, Kyoung Jin
    Jung, Sang Woo
    Shin, Doo Chul
    Shin, Seung Ho
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (01) : 81 - 85
  • [27] Training to Maximize Economy of Motion in Running Gait
    McCann, Daniel J.
    Higginson, Brian K.
    [J]. CURRENT SPORTS MEDICINE REPORTS, 2008, 7 (03) : 158 - 162
  • [28] THE MECHANICS OF RUNNING - HOW DOES STIFFNESS COUPLE WITH SPEED
    MCMAHON, TA
    CHENG, GC
    [J]. JOURNAL OF BIOMECHANICS, 1990, 23 : 65 - 78
  • [29] The effects of walking, running, and shoe size on foot volumetrics
    McWhorter, JW
    Wallmann, H
    Landers, M
    Altenburger, B
    LaPorta-Krum, L
    Altenburger, P
    [J]. PHYSICAL THERAPY IN SPORT, 2003, 4 (02) : 87 - 92
  • [30] A simple method for measuring stiffness during running
    Morin, JB
    Dalleau, G
    Kyröläinen, H
    Jeannin, T
    Belli, A
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2005, 21 (02) : 167 - 180