Comparison of Home Blood Pressure Measurement Devices on Artificial Signals

被引:0
作者
Havlik, Jan [1 ]
Susankova, Marketa [1 ]
机构
[1] Czech Tech Univ, Fac Elect Engn, Tech 2, CZ-16627 Prague 6, Czech Republic
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2 | 2019年 / 68卷 / 02期
关键词
Blood pressure; Tonometers; Self-measurement; Device comparison; HYPERTENSION;
D O I
10.1007/978-981-10-9038-7_174
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiovascular diseases are well known as one of the leading causes of death in developed countries. The hypertension is a significant danger and should be monitor carefully. In recent decades, auscultatory and oscillometric methods become as widely used for blood pressure measurement. In clinical practice, blood pressure measuring devices are evaluated according to validating protocols. Despite these protocols, a market with the automatic devices for home self-measurement of the blood pressure is flooded by a lot of cheap devices with doubtful accuracy. The aim of this study is to compare selected devices for the self-measurement in the home conditions. The devices were evaluated using the blood pressure simulators. For each device and each type of blood pressure signal, the absolute and the relative errors of the diastolic and the systolic pressures were evaluated. The obtained results show that the measurement error of these devices could be frequently higher than 5 mmHg and it is necessary to concern with the accuracy of the devices.
引用
收藏
页码:941 / 944
页数:4
相关论文
共 10 条
[1]  
[Anonymous], 1987, ELECT AUTOMATED SPHY
[2]   Guidelines for the use of self-blood pressure monitoring: a summary report of the first international consensus conference [J].
Asmar, R ;
Zanchetti, A .
JOURNAL OF HYPERTENSION, 2000, 18 (05) :493-508
[3]   Epidemiology of Aging [J].
Ferrucci, Luigi ;
Giallauria, Francesco ;
Guralnik, Jack M. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2008, 46 (04) :643-+
[4]   THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
OMALLEY, K ;
JAMIESON, M ;
ALTMAN, D ;
BLAND, M ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1990, 8 (07) :607-619
[5]   Principles and Techniques of Blood Pressure Measurement [J].
Ogedegbe, Gbenga ;
Pickering, Thomas .
CARDIOLOGY CLINICS, 2010, 28 (04) :571-+
[6]  
Tsuji I, 1997, AM J HYPERTENS, V10, P409
[7]   Arterial stiffness as underlying mechanism of disagreement between an oscillometric blood pressure monitor and a sphygmomanometer [J].
van Popele, NM ;
Bos, WJW ;
de Beer, NAM ;
van der Kuip, DAM ;
Hofman, A ;
Grobbee, DE ;
Witteman, JCM .
HYPERTENSION, 2000, 36 (04) :484-488
[8]   Hypertension, prevalence and blood pressure levels in 6 European countries, Canada, and the United States [J].
Wolf-Maier, K ;
Cooper, RS ;
Banegas, JR ;
Giampaoli, S ;
Hense, HW ;
Joffres, M ;
Kastarinen, M ;
Poulter, N ;
Primatesta, P ;
Rodríguez-Artalejo, F ;
Stegmayr, B ;
Thamm, M ;
Tuomilehto, J ;
Vanuzzo, D ;
Vescio, F .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (18) :2363-2369
[9]  
World Health Organization, 2013, World Health Day
[10]  
World Health Organization, 2015, WORLD HLTH STAT 2015