Biomechanical Analysis and Review of Lateral Lumbar Fusion Constructs

被引:134
作者
Cappuccino, Andrew [1 ]
Cornwall, G. Bryan [2 ]
Turner, Alexander W. L. [2 ]
Fogel, Guy R. [3 ]
Duong, Huy T. [4 ]
Kim, Kee D. [4 ]
Brodke, Darrel S. [5 ]
机构
[1] Buffalo Spine Surg, Lockport, NY 14094 USA
[2] NuVasive Inc, San Diego, CA USA
[3] Orthopaed Spine Inst, San Antonio, TX USA
[4] Univ Calif Davis, Dept Neurol Surg, Davis, CA 95616 USA
[5] Univ Utah, Dept Orthopaed, Salt Lake City, UT USA
关键词
lumbar interbody fusion; range of motion; extreme lateral; stability; XLIF; BACK MUSCLE INJURY; INTERBODY FUSION; SPINE SURGERY; IN-VITRO; PERIOPERATIVE COMPLICATIONS; INSTRUMENTATION TECHNIQUES; HISTOCHEMICAL ANALYSES; ANTERIOR; POSTERIOR; FIXATION;
D O I
10.1097/BRS.0b013e318202308b
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Biomechanical study and the review of literature on lumbar interbody fusion constructs. Objective. To demonstrate the comparative stabilizing effects of lateral interbody fusion with various supplemental internal fixation options. Summary of Background Data. Lumbar interbody fusion procedures are regularly performed using anterior, posterior, and more recently, lateral approaches. The biomechanical profile of each is determined by the extent of resection of local supportive structures, implant size and orientation, and the type of supplemental internal fixation used. Methods. Pure moment flexibility testing was performed using a custom-built 6 degree-of-freedom system to apply a moment of +/- 7.5 Nm in each motion plane, while motion segment kinematics were evaluated using an optoelectronic motion system. Constructs tested included the intact spine, stand-alone extreme lateral interbody implant, interbody implant with lateral plate, unilateral and bilateral pedicle screw fixation. These results were evaluated against those from literature-reported biomechanical studies of other lumbar interbody constructs. Results. All conditions demonstrated a statistically significant reduction in range of motion (ROM) as a percentage of intact. In flexion-extension, ROM was 31.6% stand-alone, 32.5% lateral fixation, and 20.4% and 13.0% unilateral and bilateral pedicle screw fixation, respectively. In lateral bending, the trend was similar with greater reduction with lateral fixation than in flexion-extension; ROM was 32.5% stand-alone, 15.9% lateral fixation, and 21.6% and 14.4% unilateral and bilateral pedicle screw fixation. ROM was greatest in axial rotation; 69.4% stand-alone, 53.4% lateral fixation, and 51.3% and 41.7% unilateral and bilateral pedicle screw fixation, respectively. Conclusion. The extreme lateral interbody construct provided the largest stand-alone reduction in ROM compared with literature-reported ALIF and TLIF constructs. Supplemental bilateral pedicle screw-based fixation provided the overall greatest reduction in ROM, similar among all interbody approach techniques. Lateral fixation and unilateral pedicle screw fixation provided intermediate reductions in ROM. Clinically, surgeons may evaluate these comparative results to choose fixation options commensurate with the stability requirements of individual patients.
引用
收藏
页码:S361 / S367
页数:7
相关论文
共 37 条
  • [1] Supplementary stabilization with anterior lumbar intervertebral fusion - A radiologic review
    Anjarwalla, Naffis K.
    Morcom, Russel K.
    Fraser, Robert D.
    [J]. SPINE, 2006, 31 (11) : 1281 - 1287
  • [2] Stand-alone anterior lumbar discectomy and fusion with plate: initial experience
    Aryan, Henry E.
    Lu, Daniel C.
    Acosta, Frank L.
    Ames, Christopher P.
    [J]. SURGICAL NEUROLOGY, 2007, 68 (01): : 7 - 13
  • [3] Video-assisted ALIF with cage and anterior plate fixation for L5-S1 spondylolisthesis
    Aunoble, Stephane
    Hoste, David
    Donkersloot, Peter
    Liquois, Frederic
    Basso, Yann
    Le Huec, Jean-Charles
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (07): : 471 - 476
  • [4] VASCULAR INJURY IN ANTERIOR LUMBAR SURGERY
    BAKER, JK
    REARDON, PR
    REARDON, MJ
    HEGGENESS, MH
    [J]. SPINE, 1993, 18 (15) : 2227 - 2230
  • [5] In vitro, biomechanical comparison of an anterior lumbar interbody fusion with an anteriorly placed, low-profile lumbar plate and posteriorly placed pedicle screws or translaminar screws
    Beaubien, BP
    Derincek, A
    Lew, WD
    Wood, KB
    [J]. SPINE, 2005, 30 (16) : 1846 - 1851
  • [6] Beringer Will F, 2006, Neurosurg Focus, V20, pE4
  • [7] Bess R, 2008, EXTREME LATERAL INTE, P31
  • [8] Spine Extreme lateral interbody fusion - XLIF
    Billinghurst, Jason
    Akbarnia, Behrooz A.
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (03): : 238 - 251
  • [9] Early outcomes and safety of the minimally invasive, lateral retroperitoneal transpsoas approach for adult degenerative scoliosis
    Dakwar, Elias
    Cardona, Rafael F.
    Smith, Donald A.
    Uribe, Juan S.
    [J]. NEUROSURGICAL FOCUS, 2010, 28 (03) : 1 - 7
  • [10] Deutsch Harel, 2006, Neurosurg Focus, V20, pE10