Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis

被引:6
|
作者
Wakami, Tatsuto [1 ]
Koizumi, Shigeki [1 ]
Koyama, Tadaaki [1 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Cardiovasc Surg, Chuo Ku, 2-1-1 Minatojima Minamimachi, Kobe, Hyogo 650047, Japan
关键词
Trifecta; Aortic valve; Structural valve deterioration; DEGENERATION; DURABILITY; FAILURE; TEAR;
D O I
10.1186/s13019-022-01918-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Several studies have reported high rates of structural valve deterioration (SVD) in the Trifecta valves. Herein, we analyzed the midterm results of the Trifecta valve and risk factors for early SVD. Methods We retrospectively reviewed the records of 110 patients who had undergone Trifecta implantation between January 2012 and December 2017. Results We encountered seven cases of Trifecta valve failure. We performed a redo aortic valve replacement in five patients and a transcatheter aortic valve replacement in two patients. The SVD rate was 4.8% at 5 years and 6.6% at 7 years. The mean pressure gradient and peak velocity on the first postoperative echocardiogram in patients with SVD were higher than those in patients without SVD. The SVD rates with and without patient-prosthesis mismatch (PPM) were 2.8% and 12.6% at 5 years and 2.8% and 20.0% at 7 years. PPM is a risk factor for SVD. Noncoronary cusp tears were observed in all patients who had undergone redo surgery. Conclusions The most common cause of SVD was noncoronary cusp tear. Patients with PPM are at high risk of developing SVD.
引用
收藏
页数:8
相关论文
共 48 条
  • [21] Prosthesis-Patient Mismatch and Mitral Regurgitation Persistence Late after Aortic Valve Replacement
    Angeloni, Emiliano
    Benedetto, Umberto
    Refice, Simone
    Santini, Daria
    Ciavarella, Giuseppino M.
    Roscitano, Antonino
    Melina, Giovanni
    Sinatra, Riccardo
    CIRCULATION, 2010, 122 (21)
  • [22] Analysis of Incidence and Reasons for Re-intervention After Aortic Valve Replacement Using the Trifecta Aortic Bioprosthesis
    Fard, Amir
    Mahmood, Zahid
    Nair, Sukumaran
    Shaikhrezai, Kasra
    Al-Attar, Nawwar
    CURRENT PROBLEMS IN CARDIOLOGY, 2023, 48 (06)
  • [23] Hemodynamically significant prosthesis-patient mismatch can be predicted and is associated with early prosthetic valve dysfunction in aortic bioprosthesis
    Ronderos, Ricardo
    Teresa Politi, Maria
    Cecilia Mahia, Mariana
    Florencia Castro, Maria
    Sciancalepore, Agustina
    Cueva Torres, Franklin
    Kuschnir, Paola
    de la Paz Ricapito, Maria
    Mariano Vrancic, Juan
    Camporrotondo, Mariano
    Piccinini, Fernando
    Navia, Daniel
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (06): : 814 - 824
  • [24] Prosthesis-patient Mismatch Affects Long-term Survival After Aortic Valve Replacement
    Ennker, Juergen
    Albert, Alexander
    Boening, Andreas
    Ennker, Ina C.
    Florath, Ines
    CIRCULATION, 2010, 122 (21)
  • [25] Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Muratori, Manuela
    Delgado, Victoria
    Pepi, Mauro
    Tamborini, Gloria
    Fusini, Laura
    Klautz, Robert J. M.
    Gripari, Paola
    Bax, Jeroen J.
    Fusari, Melissa
    Schalij, Martin J.
    Marsan, Nina Ajmone
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1910 - 1918
  • [26] Early Structural Valve Deterioration of Mitroflow Aortic Bioprosthesis Mode, Incidence, and Impact on Outcome in a Large Cohort of Patients
    Senage, Thomas
    Le Tourneau, Thierry
    Foucher, Yohann
    Pattier, Sabine
    Cueff, Caroline
    Michel, Magali
    Serfaty, Jean-Michel
    Mugniot, Antoine
    Perigaud, Christian
    Carton, Hubert Francois
    Al Habash, Ousama
    Baron, Olivier
    Roussel, Jean Christian
    CIRCULATION, 2014, 130 (23) : 2012 - 2020
  • [27] Real Structural Valve Deterioration of the Mitroflow Aortic Prosthesis: Competing Risk Analysis
    Diaz, Rocio
    Hernandez-Vaquero, Daniel
    Silva, Jacobo
    Pascual, Isaac
    de la Hera, Jesus M.
    Leon, Victor
    Martin, Maria
    Barriales, Vicente
    Colunga, Santiago
    del Valle, Raquel
    Moris, Cesar
    REVISTA ESPANOLA DE CARDIOLOGIA, 2017, 70 (12): : 1074 - 1081
  • [28] Patient–prosthesis mismatch increases the mean platelet volume in patients with aortic valve replacement
    Huseyin Bayram
    Mete Hidiroglu
    Levent Cetin
    Omer Faruk Cicek
    Aslihan Kucuker
    Emrah Uguz
    Kemal Esref Erdogan
    Erol Sener
    Surgery Today, 2015, 45 : 559 - 563
  • [29] Incidence and Predictors of Structural Valve Deterioration after Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis
    Long, Yu-Xiang
    Liu, Zeng-Zhang
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2020, 2020
  • [30] Mini-aortic valve replacements are not associated with an increased incidence of patient-prosthesis mismatch: a propensity-scored analysis
    Magruder, J. Trent
    Grimm, Joshua C.
    Kilic, Arman
    Crawford, Todd
    Conte, John V.
    Cameron, Duke E.
    Shah, Ashish S.
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (03) : 144 - 148