Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit

被引:10
作者
Choi, Eun Joo [1 ]
Go, Gwangcheol [1 ]
Han, Woong Ki [1 ]
Lee, Pyung-Bok [1 ,2 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Anesthesiol & Pain Med, 82 Gumi Ro 173beon Gil, Seongnam 13620, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
关键词
Anesthesia; Epidural; Cervical Vertebrae; Chronic Pain; Eye; Fluoroscopy; Physicians; Protection; Radiation; Thyroid Gland; IONIZING-RADIATION; LEAD APRONS; CATARACT; EDUCATION; DAMAGE; RISK;
D O I
10.3344/kjp.2020.33.1.73
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The aim of this study was to evaluate radiation exposure to the eye and thyroid in pain physicians during the fluoroscopy-guided cervical epidural block (CEB). Methods: Two pain physicians (a fellow and a professor) who regularly performed C-arm fluoroscopy-guided CEBs were included. Seven dosimeters were used to measure radiation exposure, five of which were placed on the physician (forehead, inside and outside of the thyroid protector, and inside and outside of the lead apron) and two were used as controls. Patient age, sex, height, and weight were noted, as were radiation exposure time, absorbed radiation dose, and distance from the X-ray field center to the physician. Results: One hundred CEB procedures using C-arm fluoroscopy were performed on comparable patients. Only the distance from the X-ray field center to the physician was significantly different between the two physicians (fellow: 37.5 +/- 2.1 cm, professor: 41.2 +/- 3.6 cm, P = 0.03). The use of lead-based protection effectively decreased the absorbed radiation dose by up to 35%. Conclusions: Although there was no difference in radiation exposure between the professor and the fellow, there was a difference in the distance from the X-ray field during the CEBs. Further, radiation exposure can be minimized if proper protection (thyroid protector, leaded apron, and eyewear) is used, even if the distance between the X-ray beam and the pain physician is small. Damage from frequent, low-dose radiation exposure is not yet fully understood. Therefore, safety measures, including lead-based protection, should always be enforced.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 36 条
  • [1] The biological effects of diagnostic cardiac imaging on chronically exposed physicians: The importance of being non-ionizing
    Andreassi M.G.
    [J]. Cardiovascular Ultrasound, 2 (1)
  • [2] Epidural Injections for Spinal Pain A Systematic Review and Meta-analysis Evaluating the "Control" Injections in Randomized Controlled Trials
    Bicket, Mark C.
    Gupta, Anita
    Brown, Charlie H.
    Cohen, Steven P.
    [J]. ANESTHESIOLOGY, 2013, 119 (04) : 907 - 931
  • [3] Radiation safety education in vascular surgery training
    Bordoli, Stefano J.
    Carsten, Christopher G., III
    Cull, David L.
    Johnson, Brent L.
    Taylor, Spence M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 59 (03) : 860 - U328
  • [4] Bose Bikash, 2005, Spine J, V5, P558, DOI 10.1016/j.spinee.2005.03.015
  • [5] Botwin K P, 2001, Pain Physician, V4, P343
  • [6] Botwin Kenneth P, 2003, Pain Physician, V6, P295
  • [7] Radiation exposure of the spinal interventionalist performing fluoroscopically guided lumbar transforaminal epidural steroid injections
    Botwin, KP
    Thomas, S
    Gruber, RD
    Torres, FM
    Bouchlas, CC
    Rittenberg, JJ
    Rao, S
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (05): : 697 - 701
  • [8] Cervical Epidural Steroid Injections for the Treatment of Cervical Spinal (Neck) Pain
    Candido, Kenneth D.
    Knezevic, Nebojsa 'Nick'
    [J]. CURRENT PAIN AND HEADACHE REPORTS, 2013, 17 (02)
  • [9] Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management
    Cheon, Bo Kyung
    Kim, Cho Long
    Kim, Ka Ram
    Kang, Min Hye
    Lim, Jeong Ae
    Woo, Nam Sik
    Rhee, Ka Young
    Kim, Hae Kyoung
    Kim, Jae Hun
    [J]. KOREAN JOURNAL OF PAIN, 2018, 31 (04) : 244 - 252
  • [10] Risk of cataract after exposure to low doses of ionizing radiation: A 20-year prospective cohort study among US radiologic technologists
    Chodick, Gabriel
    Bekiroglu, Nural
    Hauptmann, Michael
    Alexander, Bruce H.
    Freedman, D. Michal
    Doody, Michele Morin
    Cheung, Li C.
    Simon, Steven L.
    Weinstock, Robert M.
    Bouville, Andre
    Sigurdson, Alice J.
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2008, 168 (06) : 620 - 631