Non-invasive monitoring of blood haemoglobin for analysis of fluid volume kinetics

被引:31
作者
Hahn, R. G. [1 ]
Li, Y. [1 ,2 ]
Zdolsek, J. [1 ]
机构
[1] Linkoping Univ, Fac Hlth Sci, Dept Anaesthesia, Linkoping, Sweden
[2] Zhejiang Univ, Dept Anaesthesia, Affiliated Hosp 1, Coll Med, Hangzhou 310003, Zhejiang, Peoples R China
关键词
RINGERS SOLUTION; VOLUNTEERS;
D O I
10.1111/j.1399-6576.2010.02321.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background A commercially available pulse oximeter that reports blood haemoglobin (Hb) concentration is evaluated. This study considers whether this device can provide serial Hb data that would be sufficiently reliable for volume kinetic analysis of infusion fluids. Methods Forty infusions of 5 or 10 ml/kg of acetated Ringer's solution were given over 15 min in 10 healthy volunteers. Hb was measured on 17 different occasions over 120 min using the Radical 7 pulse oximeter and compared with the result of invasive blood sampling (control). A one-volume kinetic model was applied to each data series. The pulse oximeter also reported the perfusion index (PI). Results The median deviation between the 680 invasive and non-invasive Hb samples (the accuracy) was 1.6% and the absolute median deviation (precision) was 4.6%. Between-subject factors explained half of the variation in the difference between non-invasive vs. invasive sampling. Ten of the 40 non-invasive series of Hb values were discarded from kinetic analysis due to poor quality. The remaining 30 series showed a smaller distribution volume for the infused fluid when kinetic analysis was based on the non-invasive method (3.0 vs. 5.3 l; P < 0.001). This was due to co-variance with the PI, which exaggerated the decrease in Hb caused by the infusions. The non-invasive method might provide useful kinetic data at the group level, but individual curves deviated too much from the invasive data to be reliable. Conclusions Non-invasive measurement of the Hb concentration during volume loading could not provide useful kinetic data for individuals.
引用
收藏
页码:1233 / 1240
页数:8
相关论文
共 8 条
[1]   Intra-operative colloid administration increases the clearance of a post-operative fluid load [J].
Borup, T. ;
Hahn, R. G. ;
Holte, K. ;
Ravn, L. ;
Kehlet, H. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (03) :311-317
[2]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[3]   Volume kinetics of Ringer's solution in hypovolemic volunteers [J].
Drobin, D ;
Hahn, RG .
ANESTHESIOLOGY, 1999, 90 (01) :81-91
[4]   Volume Kinetics for Infusion Fluids [J].
Hahn, Robert G. .
ANESTHESIOLOGY, 2010, 113 (02) :470-481
[5]  
Kellermann J, 2008, TELOPEA, V12, P1
[6]   Plasma and renal clearances of lactated Ringer's solution in pediatric and adult patients just before anesthesia is induced [J].
Li, Yuhong ;
Hahn, Robert G. ;
Hu, Yaoqin ;
Xiang, Yan ;
Zhu, Shengmei .
PEDIATRIC ANESTHESIA, 2009, 19 (07) :682-687
[7]  
Norberg Å, 2007, ANESTHESIOLOGY, V107, P24
[8]   MEASURING THE PREDICTIVE PERFORMANCE OF COMPUTER-CONTROLLED INFUSION PUMPS [J].
VARVEL, JR ;
DONOHO, DL ;
SHAFER, SL .
JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1992, 20 (01) :63-94