The bubble study: ultrasound confirmation of central venous catheter placement

被引:36
|
作者
Duran-Gehring, Petra E. [1 ]
Guirgis, Faheem W. [1 ]
McKee, Kristin C. [1 ]
Goggans, Susan [1 ]
Huynh Tran [2 ]
Kalynych, Colleen J. [1 ]
Wears, Robert L. [1 ]
机构
[1] Univ Florida, Coll Med, Dept Emergency Med, Jacksonville, FL USA
[2] St Mary Mercy Hosp, St Joseph Mercy Hlth Syst, Dept Internal Med, Livonia, MI USA
关键词
SUBCLAVIAN VEIN CATHETER; BEDSIDE ULTRASOUND; CHEST RADIOGRAPHY; SALINE FLUSH; COMPLICATIONS; ULTRASONOGRAPHY; PNEUMOTHORAX; DIAGNOSIS; GUIDANCE; TRAUMA;
D O I
10.1016/j.ajem.2014.10.010
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: The objective was to determine if ultrasound (US) can more rapidly confirm central venous catheter (CVC) position in comparison to chest radiography (CXR) in the emergency department. Methods: The study included a convenience sample of emergency department patients with supradiaphragmatic CVCs and a CXR for confirmation. Ultrasound was used for CVC confirmation by visualizing microbubble artifact in the right atrium after injection of saline through the distal port. To evaluate for pneumothorax (PTX), "sliding sign" of the pleura was noted on US of the anterior chest. Blinded chart review was performed to assess CXR timing, catheter position and CVC complications. Student's t test was used to compare US time to CXR performance time and radiologist reading time. Results: Fifty patients were enrolled; 4 were excluded because of inadequate views. Forty-six patients were included in the final analysis. Mean total US time was 5.0 minutes (95% confidence interval [CI], 4.2-5.9) compared to 28.2 minutes (95% CI, 16.8-39.4) for CXR performance with a mean difference of 23.1 minutes (95% CI, -34.5 to -11.8; P < .0002). When comparing only US CVC confirmation time to CXR time, US was an average of 24.0 minutes (95% CI, -35.4 to -12.7; P < .0001) faster. Comparing total US time to radiologist CXR reading time, US was an average of 294 minutes faster (95% CI, -384.5 to -203.5; P < .0000). There were a total of 3 misplaced lines and 2 patients with PTX, all of which were identified correctly on US. Conclusion: Ultrasound can confirm CVC placement and rule out PTX significantly faster than CXR, expediting the use of CVCs in the critically ill. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:315 / 319
页数:5
相关论文
共 50 条
  • [1] Prospective comparison of ultrasound and CXR for confirmation of central vascular catheter placement
    Weekes, Anthony J.
    Keller, Stephen M.
    Efune, Bradley
    Ghali, Sama
    Runyon, Michael
    EMERGENCY MEDICINE JOURNAL, 2016, 33 (03) : 176 - 180
  • [2] The Ultrasound-Only Central Venous Catheter Placement and Confirmation Procedure
    Saul, Turandot
    Doctor, Michael
    Kaban, Nicole L.
    Avitabile, Nicholas C.
    Siadecki, Sebastian D.
    Lewiss, Resa E.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (07) : 1301 - 1306
  • [3] Point-of-care Ultrasound-guided Central Venous Catheter Confirmation in Ultrasound Nonexperts
    Ablordeppey, Enyo A.
    Drewry, Anne M.
    Anderson, Adam L.
    Casali, Diego
    Wallace, Laura A.
    Kane, Deborah S.
    Tian, LinLin
    House, Stacey L.
    Fuller, Brian M.
    Griffey, Richard T.
    Theodoro, Daniel L.
    AEM EDUCATION AND TRAINING, 2021, 5 (03)
  • [4] Confirmation of correct central venous catheter position in the preoperative setting by echocardiographic "bubble-test"
    Meggiolaro, M.
    Scatto, A.
    Zorzi, A.
    Roman-Pognuz, E.
    Lauro, A.
    Passarella, C.
    Bonaccorso, G.
    MINERVA ANESTESIOLOGICA, 2015, 81 (09) : 989 - 1000
  • [5] Use of Contrast-Enhanced Ultrasound for Confirmation of Central Venous Catheter Placement: Systematic Review and Meta-analysis
    Chebl, Ralph Bou
    Kiblawi, Shafeek
    El Khuri, Christopher
    El Hajj, Nadine
    Bachir, Rana
    Aoun, Roni
    Abou Dagher, Gilbert
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (12) : 2503 - 2510
  • [6] Use of ultrasound for central venous catheter placement
    T Angelini
    L Bevilacqua
    F Forfori
    G Licitra
    L DeSimone
    F Giunta
    Critical Care, 12 (Suppl 2):
  • [7] Development and Evaluation of a Program for the Use of Ultrasound for Central Venous Catheter Placement in a Pediatric Emergency Department
    Vieira, Rebecca L.
    Gallagher, Rachel A.
    Stack, Anne M.
    Werner, Heidi C.
    Levy, Jason A.
    PEDIATRIC EMERGENCY CARE, 2013, 29 (12) : 1245 - 1248
  • [8] CURRENT PRACTICES IN CENTRAL VENOUS CATHETER POSITION CONFIRMATION BY POINT OF CARE ULTRASOUND: A SURVEY OF EARLY ADOPTERS
    Ablordeppey, Enyo A.
    Drewry, Anne M.
    Theodoro, Daniel L.
    Tian, LinLin
    Fuller, Brian M.
    Griffey, Richard T.
    SHOCK, 2019, 51 (05): : 613 - 618
  • [9] The FLUSH Study-Flush the Line and Ultrasound the Heart: Ultrasonographic Confirmation of Central Femoral Venous Line Placement
    Horowitz, Russ
    Gossett, Jeffrey G.
    Bailitz, John
    Wax, David
    Pierce, Mary Clyde
    ANNALS OF EMERGENCY MEDICINE, 2014, 63 (06) : 678 - 683
  • [10] Confirmation of endovenous placement of central catheter using the ultrasonographic "bubble test"
    Baviskar, Ajit S.
    Khatib, Khalid I.
    Bhoi, Sanjeev
    Galwankar, Sagar C.
    Dongare, Harshad C.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2015, 19 (01) : 38 - 41