Feasibility and Safety of the Novel Vivolight Frequency Domain Optical Coherence Tomography System: A Multicenter Study

被引:0
作者
Jin, Qinhua [1 ]
Qian, Juying [2 ]
Zhou, Yujie [3 ]
Jing, Jing [1 ]
Wu, Yizhe [2 ]
Liu, Yuyang [3 ]
Shen, Hua [3 ]
Guo, Jun [1 ]
Sun, Zhijun [1 ]
Wang, Yu [1 ]
Chen, Lian [1 ]
Chen, Yundai [1 ]
机构
[1] Gen Hosp Peoples Liberat Army, Dept Cardiol, 28 Fuzing Rd, Beijing, Wukesong, Peoples R China
[2] Fudan Univ, Zhongshan Hosp, Dept Cardiol, Shanghai, Peoples R China
[3] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing, Peoples R China
关键词
coronary artery disease; feasibility; optical coherence tomography; safety; PERCUTANEOUS CORONARY INTERVENTION; INTRAVASCULAR ULTRASOUND; STENT IMPLANTATION; DECISION-MAKING; ANGIOGRAPHY; GUIDANCE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. The study sought to assess the effectiveness and safety of the novel P60 Vivolight frequency-domain optical coherence tomography (OCT) system (Shenzhen Vivolight Medical Device & Technology). Methods. A total of 90 patients were enrolled from 3 institutions. The pullbacks were performed with both the P60 Vivolight OCT system and the Ilumien Optis OCT system (Abbott Vascular). The primary endpoint was the clear stent length (CSL). Device safety was assessed by the record of serious procedure-related or postprocedure adverse events. The secondary endpoints were the average lumen area of stent, clear image length (CIL), system stability, and imaging catheter operability. Results. The mean relative errors of CSL were 3.30% (95% confidence interval [CI], -0.71 to 7.31) in the full analysis set (FAS) and 0.83% (95% CI, -1.79 to 3.45) in the per-protocol set (PPS). The mean relative errors of the average lumen area of stent were 2.20% (95% CI, 0.70 to 3.80) in the FAS and 1.55% (95% CI, 0.30 to 2.80) in the PPS. No difference was observed in the percentage of obtaining >24 mm of CIL (93.18% in the P60 Vivolight group vs 95.45% in the Ilumien Optis group; P=.48). There were no serious procedure-related or postprocedure adverse events. Conclusions. The feasibility and safety of the novel Vivolight OCT system is equivalent to that of the Ilumien Optis OCT system.
引用
收藏
页码:E412 / E416
页数:5
相关论文
共 14 条
  • [1] Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial
    Ali, Ziad A.
    Maehara, Akiko
    Genereux, Philippe
    Shlofmitz, Richard A.
    Fabbiocchi, Franco
    Nazif, Tamim M.
    Guagliumi, Giulio
    Meraj, Perwaiz M.
    Alfonso, Fernando
    Samady, Habib
    Akasaka, Takashi
    Carlson, Eric B.
    Leesar, Massoud A.
    Matsumura, Mitsuaki
    Ozan, Melek Ozgu
    Mintz, Gary S.
    Ben-Yehuda, Ori
    Stone, Gregg W.
    [J]. LANCET, 2016, 388 (10060) : 2618 - 2628
  • [2] Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention With Stent Implantation A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients
    Buccheri, Sergio
    Franchina, Gabriele
    Romano, Sara
    Puglisi, Sebastiano
    Venuti, Giuseppe
    D'Arrigo, Paolo
    Francaviglia, Bruno
    Scalia, Matteo
    Condorelli, Antonio
    Barbanti, Marco
    Capranzano, Piera
    Tamburino, Corrado
    Capodanno, Davide
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (24) : 2488 - 2498
  • [3] Accuracy of intravascular ultrasound and optical coherence tomography in identifying functionally significant coronary stenosis according to vessel diameter: A meta-analysis of 2,581 patients and 2,807 lesions
    D'Ascenzo, Fabrizio
    Barbero, Umberto
    Cerrato, Enrico
    Lipinski, Michael J.
    Omede, Pierluigi
    Montefusco, Antonio
    Taha, Salma
    Naganuma, Toru
    Reith, Sebastian
    Voros, Szilard
    Latib, Azeem
    Gonzalo, Nieves
    Quadri, Giorgio
    Colombo, Antonio
    Biondi-Zoccai, Giuseppe
    Escaned, Javier
    Moretti, Claudio
    Gaita, Fiorenzo
    [J]. AMERICAN HEART JOURNAL, 2015, 169 (05) : 663 - 673
  • [4] Impact of Frequency-Domain Optical Coherence Tomography Guidance for Optimal Coronary Stent Implantation in Comparison With Intravascular Ultrasound Guidance
    Habara, Maoto
    Nasu, Kenya
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Yokota, Daisuke
    Ko, Euihong
    Ito, Tsuyoshi
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Ito, Tatsuya
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Asakura, Keiko
    Asakura, Yasushi
    Katoh, Osamu
    Suzuki, Takahiko
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) : 193 - 201
  • [5] Prevalence and predictors of culprit plaque rupture at OCT in patients with coronary artery disease: a meta-analysis
    Iannaccone, Mario
    Quadri, Giorgio
    Taha, Salma
    D'Ascenzo, Fabrizio
    Montefusco, Antonio
    Omede', Pierluigi
    Jang, Ik-Kyung
    Niccoli, Giampaolo
    Souteyrand, Geraud
    Chen Yundai
    Toutouzas, Konstantinos
    Benedetto, Sara
    Barbero, Umberto
    Annone, Umberto
    Lonni, Enrica
    Imori, Yoichi
    Biondi-Zoccai, Giuseppe
    Templin, Christian
    Moretti, Claudio
    Luscher, Thomas F.
    Gaita, Fiorenzo
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (10) : 1128 - 1137
  • [6] Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention
    Imola, Fabrizio
    Mallus, Maria Teresa
    Ramazzotti, Vito
    Manzoli, Alessandro
    Pappalardo, Alessandro
    Di Giorgio, Alessandro
    Albertucci, Mario
    Prati, Francesco
    [J]. EUROINTERVENTION, 2010, 6 (05) : 575 - 581
  • [7] Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINIONtrial): one-year angiographic and clinical results
    Kubo, Takashi
    Shinke, Toshiro
    Okamura, Takayuki
    Hibi, Kiyoshi
    Nakazawa, Gaku
    Morino, Yoshihiro
    Shite, Junya
    Fusazaki, Tetsuya
    Otake, Hiromasa
    Kozuma, Ken
    Ioji, Tetsuya
    Kaneda, Hideaki
    Serikawa, Takeshi
    Kataoka, Toru
    Okada, Hisayuki
    Akasaka, Takashi
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (42) : 3139 - 3147
  • [8] Feasibility of Optical Coronary Tomography in Quantitative Measurement of Coronary Arteries With Lipid-Rich Plaque
    Kubo, Takashi
    Yamano, Takashi
    Liu, Yong
    Ino, Yasushi
    Shiono, Yasutsugu
    Orii, Makoto
    Taruya, Akira
    Nishiguchi, Tsuyoshi
    Shimokado, Aiko
    Teraguchi, Ikuko
    Tanimoto, Takashi
    Kitabata, Hironori
    Yamaguchi, Tomoyuki
    Hirata, Kumiko
    Tanaka, Atsuhi
    Akasaka, Takashi
    [J]. CIRCULATION JOURNAL, 2015, 79 (03) : 600 - 606
  • [9] Optical coherence tomography-guided percutaneous coronary intervention compared with other imaging guidance: a meta-analysis
    Kuku, Kayode O.
    Ekanem, Emmanuel
    Azizi, Viana
    Melaku, Gebremedhin
    Bui, Anh
    Meirovich, Yael F.
    Dheendsa, Aaphtaab
    Beyene, Solomon
    Hideo-Kajita, Alexandre
    Lipinski, Michael J.
    Waksman, Ron
    Garcia-Garcia, Hector M.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (04) : 503 - 513
  • [10] Intracoronary Optical Diagnostics Current Status, Limitations, and Potential
    Lowe, Harry C.
    Narula, Jagat
    Fujimoto, James G.
    Jang, Ik-Kyung
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (12) : 1257 - 1270