Principle and analysis of a rotational motion Fourier transform infrared spectrometer

被引:2
作者
Cai, Qisheng [1 ]
Huang, Min [1 ]
Han, Wei [1 ]
Liu, Yixuan [1 ]
Qian, Lulu [1 ]
Lu, Xiangning [1 ]
机构
[1] Chinese Acad Sci, Acad Optoelect, Key Lab Computat Opt Imaging Technol, Beijing 100094, Peoples R China
来源
EARTH OBSERVING SYSTEMS XXII | 2017年 / 10402卷
基金
中国国家自然科学基金;
关键词
Fourier transform infrared spectrometer; interferometer; optical simulation; optical path difference; tolerance; analysis;
D O I
10.1117/12.2276977
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Fourier transform infrared spectroscopy is an important technique in studying molecular energy levels, analyzing material compositions, and environmental pollutants detection. A novel rotational motion Fourier transform infrared spectrometer with high stability and ultra-rapid scanning characteristics is proposed in this paper. The basic principle, the optical path difference (OPD) calculations, and some tolerance analysis are elaborated. The OPD of this spectrometer is obtained by the continuously rotational motion of a pair of parallel mirrors instead of the translational motion in traditional Michelson interferometer. Because of the rotational motion, it avoids the tilt problems occurred in the translational motion Michelson interferometer. There is a cosine function relationship between the OPD and the rotating angle of the parallel mirrors. An optical model is setup in non-sequential mode of the ZEMAX software, and the interferogram of a monochromatic light is simulated using ray tracing method. The simulated interferogram is consistent with the theoretically calculated interferogram. As the rotating mirrors are the only moving elements in this spectrometer, the parallelism of the rotating mirrors and the vibration during the scan are analyzed. The vibration of the parallel mirrors is the main error during the rotation. This high stability and ultra-rapid scanning Fourier transform infrared spectrometer is a suitable candidate for airborne and space-borne remote sensing spectrometer.
引用
收藏
页数:7
相关论文
共 7 条
[1]  
Brierley P. R, 1990, U. S. patent, Patent No. [4,915,502, 4915502]
[2]  
Cai Q., 2014, P SOC PHOTO-OPT INS, V9142, P91421
[3]  
Griffiths P. R, 2001, FOURIER TRANSFORM IN
[4]   Ultra-rapid-scanning Fourier transform infrared spectrometry [J].
Griffiths, PR ;
Hirsche, BL ;
Manning, CJ .
VIBRATIONAL SPECTROSCOPY, 1999, 19 (01) :165-176
[5]   Interferometers based on the rotational motion [J].
Kauppinen, J ;
Heinonen, J ;
Kauppinen, I .
APPLIED SPECTROSCOPY REVIEWS, 2004, 39 (01) :99-130
[6]  
Kauppinen J. K, 1989, REP SERIES, V174
[7]   CAROUSEL INTERFEROMETER [J].
KAUPPINEN, JK ;
SALOMAA, IK ;
PARTANEN, JO .
APPLIED OPTICS, 1995, 34 (27) :6081-6085