On-Line Solid Phase Extraction and Spectrophotometric Detection with Flow Technique for the Determination of Nanomolar Level Ammonium in Seawater Samples

被引:62
作者
Chen, Guohe [1 ,2 ]
Zhang, Min [1 ]
Zhang, Zhen [1 ]
Huang, Yongming [1 ]
Yuan, Dongxing [1 ]
机构
[1] Xiamen Univ, Environm Sci Res Ctr, State Key Lab Marine Environm Sci, Xiamen 361005, Peoples R China
[2] Shaoxing Univ, Coll Life Sci, Shaoxing, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Ammonium; Seawater; Sequential injection; Solid phase extraction; WAVE-GUIDE; COLORIMETRIC DETERMINATION; ION CHROMATOGRAPHY; INJECTION ANALYSIS; ANTICYCLONIC EDDY; WATER; ENRICHMENT; ANALYZER; COASTAL; NITRITE;
D O I
10.1080/00032719.2010.500775
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of low-level ammonium in seawaters suffers from low sensitivity and high contamination; therefore, it is desirable to develop highly sensitive methods for automatic measurements. A highly sensitive and automated flow technique system for nanomolar level ammonium measurement is described. Reagents for Berthelot reaction were automatically added into seawater samples. After a 10min reaction at 40 degrees C, the formed indophenol blue compound was on-line extracted onto an Hydrophilic-Lipophilic Balance (HLB) cartridge. The enriched compound was rinsed with water and ethanol solution (30%, v/v) and, in turn, eluted with an eluent containing 30% (v/v) ethanol and 5.0mM of NaOH, and determined with a spectrophotometer at 640nm. Parameter, including extraction conditions, reagent concentrations, pH, temperature, and reaction time, were optimized. Under the optimized conditions, the detection limit was 3.5nM and the linear range was 0-428nM. The relative standard deviations were 5.7% (n=8) for 44.6nM standard solution and less than 6.0% (n=3-5) for samples within concentrations of about 52.4-288.7nM; the recovery was in the range 93.6 to 108.5%. The sample throughput was 3h-1. The proposed method provides a simple, cheap, and automatic way to determine ammonium in seawater samples without complicated sample treatment.
引用
收藏
页码:310 / 326
页数:17
相关论文
共 27 条
[1]   Determination of ammonia in seawater by the indophenol-blue method: Evaluation of the ICES NUTS I/C 5 questionnaire [J].
Aminot, A ;
Kirkwood, DS ;
Kerouel, R .
MARINE CHEMISTRY, 1997, 56 (1-2) :59-75
[2]   Shipboard fluorometric flow analyzer for high-resolution underway measurement of ammonium in Seawater [J].
Amornthammarong, Natchanon ;
Zhang, Jia-Zhong .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1019-1026
[4]   Marine nitrogen fixation: what's the fuss? [J].
Capone, DG .
CURRENT OPINION IN MICROBIOLOGY, 2001, 4 (03) :341-348
[5]   In-field determination of nanomolar nitrite in seawater using a sequential injection technique combined with solid phase enrichment and colorimetric detection [J].
Chen, Guohe ;
Yuan, Dongxing ;
Huang, Yongming ;
Zhang, Min ;
Bergman, Maria .
ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) :82-88
[6]   A critical examination of the components of the Schlieren effect in flow analysis [J].
Dias, ACB ;
Borges, EP ;
Zagatto, EAG ;
Worsfold, PJ .
TALANTA, 2006, 68 (04) :1076-1082
[7]   Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection [J].
Fukushi, K ;
Ito, H ;
Kimura, K ;
Yokota, K ;
Saito, K ;
Chayama, K ;
Takeda, S ;
Wakida, S .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1106 (1-2) :61-66
[8]   ANALYSIS OF AMMONIA AND METHYLAMINES IN NATURAL-WATERS BY FLOW-INJECTION GAS-DIFFUSION COUPLED TO ION CHROMATOGRAPHY [J].
GIBB, SW ;
MANTOURA, RFC ;
LISS, PS .
ANALYTICA CHIMICA ACTA, 1995, 316 (03) :291-304
[9]  
Grasshoff K., 1999, Methods of Seawater Analysis
[10]  
Hansen H.P., 1999, METHODS SEAWATER ANA, P159, DOI DOI 10.1002/9783527613984.CH10