Motion gated small animal imaging with a flat-panel CT

被引:2
作者
Grasruck, M. [1 ]
Bartling, S. [2 ]
Dinkel, J. [2 ]
Kiessling, F. [2 ]
Semmler, W. [2 ]
Stierstorfer, K. [1 ]
Schmidt, B. [1 ]
机构
[1] Siemens Healthcare, D-91294 Forchheim, Germany
[2] German Canc Res Ctr, D-69120 Heidelberg, Germany
来源
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2008年 / 6913卷
关键词
flat panel CT; motion gated reconstruction; small animal imaging; volume CT;
D O I
10.1117/12.769386
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Small animal CT gains increasing interest in preclinical research. However, physiological motion compensation like in clinical CT has seldom been employed so far. We present different methods of retrospective motion correction for small animal imaging despite their high respiratory and heart rate. Beside respiratory gating alone the combination of respiratory and simultaneous cardiac gating is shown. In vivo data are acquired with an experimental flat-panel based CT scanner* (Siemens Healthcare, Forchheim Germany). Whole mice or rats fit in the available FOV of 25 * 25 * 4 cm(3), while acquisition rate is 100fps. Extrinsic gating is realized by tracing the physiological motion from a small animal monitoring system with a pneumatic pillow for respiratory motion and ECG for heart motion. At the alternative intrinsic method, the lung motion is directly correlated to the movement of the center of gravity in the acquired projection data. As an advantage of the second method the even low preparation effort per scan is reduced. As long as the rotation time of the gantry is far below the cycle time of heart or the lung a multi-segment reconstruction is used in both methods. Motion artifacts are largely suppressed after gating. While in non gated images, the diaphragm, heart contours, bronchi and lung vessels are already visible, they are more sharply defined in the gated datasets. Four-dimensional assessment of lung motion is possible and lung volume in several phases such as peak inspiration and expiration could be segmented, quantified and compared.
引用
收藏
页数:8
相关论文
共 7 条
[1]  
BADEA C, 2005, MOL IMAGING, V3, P110
[2]  
BARTLING SH, EUROPEAN RA IN PRESS
[3]   Retrospective motion Gating in small animal CT of mice and rats [J].
Bartling, Soenke H. ;
Stiller, Wolfram ;
Grasruck, Michael ;
Schmidt, Bernhard ;
Peschke, Peter ;
Semmler, Wolfhard ;
Kiessling, Fabian .
INVESTIGATIVE RADIOLOGY, 2007, 42 (10) :704-714
[4]   Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner - art. no. 61422J [J].
Grasruck, M. ;
Gupta, R. ;
Reichardt, B. ;
Suess, Ch. ;
Schmidt, B. ;
Stierstorfer, K. ;
Popescu, S. ;
Brady, T. ;
Flohr, T. .
Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 :J1422-J1422
[5]  
GRASRUCK M, 2007, P SPIE MED IMAGING 2
[6]  
GRASRUCK M, 2005, P SPIE MED IMAGING 2, V5745
[7]  
POPESCU S, 2005, P SPIE MED IMAGING 2, V5745