Analysis of Short Implants and Lateralization of the Inferior Alveolar Nerve With 2-Stage Dental Implants by Finite Element Method

被引:20
|
作者
Amorim Vasco, Marco Antonio [1 ]
Hecke, Mildred Ballin [2 ]
Bezzon, Osvaldo Luiz [1 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Prosthodont & Dent Mat Dept, Sao Paulo, Brazil
[2] Univ Fed Parana, Grad Program Numer Methods Engn, BR-80060000 Curitiba, Parana, Brazil
关键词
Dental implants; finite element analysis; short implants; lateralization of the inferior alveolar nerve; MULTICENTER CLINICAL-TRIAL; LOW-LEVEL LASER; FOLLOW-UP; BONE-DENSITY; IN-VIVO; PROSTHESES; FIT; EDENTULISM; PLACEMENT; DIAMETER;
D O I
10.1097/SCS.0b013e318231993d
中图分类号
R61 [外科手术学];
学科分类号
摘要
There are difficulties for dental implant use in posterior mandible when there is little bone height for implant placement. Among the treatment alternatives available, there is no direct comparison between short implants and conventional implants placed with lateralization of the inferior alveolar nerve. The present study aimed to comparatively evaluate the risk of peri-implant bone loss of the above treatments. With this aim, computed tomography scans of mandibles were processed, and implants and prosthetic components were reverse engineered for reconstruction of three-dimensional models to simulate the biomechanical behavior of 3-element fixed partial dentures supported by 2 osseointegrated implants, using simulations with the finite element method. The models of implants were based on MK III implants (Nobel Biocare) of 5- and 4-mm diameter by 7-mm length, representing short implants, and 4- and 3.75-mm diameter by 15-mm length, representing implants used in lateralization of the inferior alveolar nerve. All models were simulated with prestress concerning the stresses generated by the torque of the screw. Axial and oblique occlusal loads at 45% were simulated, resulting in 8 different simulations. The results showed that the risk for bone loss in osseointegrated implants is greater for treatments with short implants.
引用
收藏
页码:2064 / 2071
页数:8
相关论文
共 50 条
  • [31] Prediction of Dental Implants Primary Stability With Cone Beam Computed Tomography-Based Homogenized Finite Element Analysis
    Vautrin, Antoine
    Thierrin, Raphael
    Wili, Patrik
    Klingler, Samuel
    Chappuis, Vivianne
    Varga, Peter
    Zysset, Philippe
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (02)
  • [32] Determining Position of the Inferior Alveolar Nerve via Anatomical Dissection and Micro-Computed Tomography in Preparation for Dental Implants
    Massey, Natalie D.
    Galil, Khadry A.
    Wilson, Timothy D.
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2013, 79
  • [33] Influence of Tapered and External Hexagon Connections on Bone Stresses Around Tilted Dental Implants: Three-Dimensional Finite Element Method With Statistical Analysis
    de Faria Almeida, Daniel Augusto
    Pellizzer, Eduardo Piza
    Verri, Fellippo Ramos
    Santiago, Joel Ferreira, Jr.
    Perri de Carvalho, Paulo Segio
    JOURNAL OF PERIODONTOLOGY, 2014, 85 (02) : 261 - 269
  • [34] Three-dimensional finite element analysis of stress distribution on short implants with different bone conditions and osseointegration rates
    Yang, Yunhe
    Liu, Yuchen
    Yuan, Xi
    Ren, Mingfa
    Chen, Xiaodong
    Luo, Lailong
    Zheng, Lang
    Liu, Yang
    BMC ORAL HEALTH, 2023, 23 (01)
  • [35] The effects of different grading approaches in additively manufactured dental implants on peri-implant bone stress: A finite element analysis
    Akbas, Osman
    Greuling, Andreas
    Stiesch, Meike
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 154
  • [36] Development of Effects on Chewing with Mandibular Fixed Dental Bridges with Implants via Finite Element Method
    Liu, Yun-Ting
    Cheng, Han-Yi
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2020, 10 (08) : 1071 - 1076
  • [37] The evaluation of stress on bone level and tissue level short implants: A Finite Element Analysis (FEA) study
    Avag, Canseda
    Akkocaoglu, Murat
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [38] Finite element analysis of the angle range in trans-inferior alveolar nerve implantation at the mandibular second molar
    Wu, Wenli
    Song, Liangyue
    Liu, Jinming
    Du, Lingyi
    Zhang, Yuhang
    Chen, Yingying
    Tang, Zichun
    Shen, Ming
    BMC ORAL HEALTH, 2023, 23 (01)
  • [39] Stress distribution with extra-short implants in an angled frictional system: A finite element analysis study
    Rendohl, Edelcio de Souza
    Brandt, William Cunha
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06) : 728.e1 - 728.e9
  • [40] Biomechanical behavior analysis of four types of short implants with different placement depths using the finite element method
    Li, Ruyi
    Wu, Zhanglin
    Chen, Song
    Li, Xiang
    Wan, Qianbing
    Xie, Guo
    Pei, Xibo
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (03) : 447.e1 - 447.e10