Improved detectability of experimental allergic encephalomyelitis in excised swine spinal cords by high b-value q-space DWI

被引:34
作者
Biton, IE
Mayk, A
Kidron, D
Assaf, Y
Cohen, Y [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Exact Sci, Sch Chem, IL-69978 Tel Aviv, Israel
[2] Teva Pharmaceut Ind Ltd, Netanya, Israel
[3] Tel Aviv Sourasky Med Ctr, Funct Brain Imaging Unit, Tel Aviv, Israel
[4] Meir Med Ctr, Dept Pathol, Kefar Sava, Israel
基金
以色列科学基金会;
关键词
experimental allergic encephalomyelitis; EAE; magnetic resonance imaging; MRI; diftsion-weighted MRI; DWI; q-space DWI; spinal cord;
D O I
10.1016/j.expneurol.2005.06.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Experimental allergic encephalomyelitis (EAE) is the primary experimental model of multiple sclerosis (MS), which involves both inflammation and demyelination and is known to be species-dependent. Spinal cord abnormalities were found in more than 80% of postmortem specimens of MS patients. In the present study, T-1, T-2 and high b-value q-space diffusion-weighted magnetic resonance imaging (MRI) were used, for the first time, to characterize the EAE model in excised swine spinal cords. The MR images were compared with histological staining and clinical scoring. Although all spinal cords were excised from swine with severe or very severe (clinical score between 3 to 5 on a scale of 5) motor impairments, T-1- and T-2-weighted MRI revealed white matter (WM) abnormalities in only five of the ten EAE diseased spinal cords studied, while high b-value q-space diffusion weighted MRI (q-space DWI) detected WM abnormalities in all diseased spinal cords studied. Interestingly, high b-value q-space DWI was able to detect abnormalities in the normal appearing white matter (NAWM) even in spinal cords where no plaques were identified by the T-1- and T-2-weighted MR images. Good anatomical correlation was observed between the high b-value q-space MR images and histology. The extent of DWI abnormalities paralleled the clinical scoring and correlated with histology. In addition, areas classified as NAWM by the T-1- and T-2-weighted MR images that showed abnormalities in the q space DWI were also found to have abnormal histology. This improved detection level of the EAE model by high b-value q-space DWI over conventional T-1-, and T-2-weighted MRI is briefly discussed. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 39 条
[1]   MR microscopy of transgenic mice that spontaneously acquire experimental allergic encephalomyelitis [J].
Ahrens, ET ;
Laidlaw, DH ;
Readhead, C ;
Brosnan, CF ;
Fraser, SE ;
Jacobs, RE .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (01) :119-132
[2]  
ANIJEHOLT GJL, 2001, BRAIN, V124, P154
[3]   Non-mono-exponential attenuation of water and N-acetyl aspartate signals due to diffusion in brain tissue [J].
Assaf, Y ;
Cohen, Y .
JOURNAL OF MAGNETIC RESONANCE, 1998, 131 (01) :69-85
[4]  
Assaf Y, 2000, MAGNET RESON MED, V44, P713, DOI 10.1002/1522-2594(200011)44:5<713::AID-MRM9>3.0.CO
[5]  
2-6
[6]   Hypertension and neuronal degeneration in excised rat spinal cord studied by high-b value q-space diffusion magnetic resonance imaging [J].
Assaf, Y ;
Mayk, A ;
Eliash, S ;
Speiser, Z ;
Cohen, Y .
EXPERIMENTAL NEUROLOGY, 2003, 184 (02) :726-736
[7]   High b-value q-space analyzed diffusion-weighted MRI:: Application to multiple sclerosis [J].
Assaf, Y ;
Ben-Bashat, D ;
Chapman, J ;
Peled, S ;
Biton, IE ;
Kafri, M ;
Segev, Y ;
Hendler, T ;
Korczyn, AD ;
Graif, M ;
Cohen, Y .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :115-126
[8]   Structural changes in glutamate cell swelling followed by multiparametric q-space diffusion MR of excised rat spinal cord [J].
Biton, IE ;
Mayk, A ;
Assaf, Y ;
Cohen, Y .
MAGNETIC RESONANCE IMAGING, 2004, 22 (05) :661-672
[9]   MR microscopy of magnetically labeled neurospheres transplanted into the Lewis EAE rat brain [J].
Bulte, JWM ;
Ben-Hur, T ;
Miller, BR ;
Mizrachi-Kol, R ;
Einstein, O ;
Reinhartz, E ;
Zywicke, HA ;
Douglas, T ;
Frank, JA .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :201-205
[10]   HIGH-RESOLUTION Q-SPACE IMAGING IN POROUS STRUCTURES [J].
CALLAGHAN, PT ;
MACGOWAN, D ;
PACKER, KJ ;
ZELAYA, FO .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (01) :177-182