Reconstructing the 3D Shape and Bone Mineral Density Distribution of the Proximal Femur From Dual-Energy X-Ray Absorptiometry

被引:66
作者
Whitmarsh, Tristan [1 ,2 ]
Humbert, Ludovic [1 ,2 ]
De Craene, Mathieu [1 ,2 ]
Del Rio Barquero, Luis M. [3 ]
Frangi, Alejandro F. [1 ,2 ]
机构
[1] Univ Pompeu Fabra UPF, Ctr Computat Imaging & Simulat Technol Biomed CIS, Informat & Commun Technol Dept, Barcelona 08002, Spain
[2] CIBER Bioengn Biomat & Nanomed CIBER BBN, Barcelona 08003, Spain
[3] CETIR Ctr Med, Barcelona 08003, Spain
关键词
Active appearance model; active shape model; deformable models; image reconstruction; image registration; QUANTITATIVE COMPUTED-TOMOGRAPHY; HIP FRACTURE; MODELS; CT; SEGMENTATION; REGISTRATION; CONSTRUCTION; GENERATION; STRENGTH; ATLAS;
D O I
10.1109/TMI.2011.2163074
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The accurate diagnosis of osteoporosis has gained increasing importance due to the aging of our society. Areal bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA) is an established criterion in the diagnosis of osteoporosis. This measure, however, is limited by its two-dimensionality. This work presents a method to reconstruct both the 3D bone shape and 3D BMD distribution of the proximal femur from a single DXA image used in clinical routine. A statistical model of the combined shape and BMD distribution is presented, together with a method for its construction from a set of quantitative computed tomography (QCT) scans. A reconstruction is acquired in an intensity based 3D-2D registration process whereby an instance of the model is found that maximizes the similarity between its projection and the DXA image. Reconstruction experiments were performed on the DXA images of 30 subjects, with a model constructed from a database of QCT scans of 85 subjects. The accuracy was evaluated by comparing the reconstructions with the same subject QCT scans. The method presented here can potentially improve the diagnosis of osteoporosis and fracture risk assessment from the low radiation dose and low cost DXA devices currently used in clinical routine.
引用
收藏
页码:2101 / 2114
页数:14
相关论文
共 52 条
[11]   SCREE TEST FOR NUMBER OF FACTORS [J].
CATTELL, RB .
MULTIVARIATE BEHAVIORAL RESEARCH, 1966, 1 (02) :245-276
[12]   Assessment of the strength of proximal femur in vitro: Relationship to femoral bone mineral density and femoral geometry [J].
Cheng, XG ;
Lowet, G ;
Boonen, S ;
Nicholson, PHF ;
Brys, P ;
Nijs, J ;
Dequeker, J .
BONE, 1997, 20 (03) :213-218
[13]  
Chintalapani G, 2007, LECT NOTES COMPUT SC, V4791, P499
[14]  
Fleute M., 2002, Medical Image Computing and Computer-Assisted Intervention - MICCAI 2002. 5th International Conference. Proceedings, Part II (Lecture Notes in Computer Science Vol.2489), P364
[15]   Automatic construction of multiple-object three-dimensional statistical shape models: Application to cardiac modeling [J].
Frangi, AF ;
Rueckert, D ;
Schnabel, JA ;
Niessen, WJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1151-1166
[16]  
*FRAX WHO FRACT RI, FRAX WHO FRACT RISK
[17]  
Fritscher K, 2008, LECT NOTES COMPUT SC, V5241, P568, DOI 10.1007/978-3-540-85988-8_68
[18]   Trabecular Bone Analysis in CT and X-Ray Images of the Proximal Femur for the Assessment of Local Bone Quality [J].
Fritscher, Karl ;
Gruenerbl, Agnes ;
Haenni, Markus ;
Suhm, Norbert ;
Hengg, Clemens ;
Schubert, Rainer .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) :1560-1575
[19]   3D image segmentation using combined shape-intensity prior models [J].
Fritscher, Karl D. ;
Gruenerbl, Agnes ;
Schubert, Rainer .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 1 (06) :341-350
[20]   Average brain models: A convergence study [J].
Guimond, A ;
Meunier, J ;
Thirion, JP .
COMPUTER VISION AND IMAGE UNDERSTANDING, 2000, 77 (02) :192-210