Year long monitoring of indoor air quality and ventilation in school classrooms in Victoria, Australia

被引:12
作者
Rajagopalan, Priyadarsini [1 ]
Andamon, Mary Myla [1 ]
Woo, Jin [1 ]
机构
[1] RMIT Univ, Sch Property Construct & Project Management, Sustainable Bldg Innovat Lab, 124 La Trobe St, Melbourne, Vic 3000, Australia
关键词
Indoor air quality; school classrooms; CO2; concentration; ventilation; air change rates; particulate matter; RATES; HEALTH; PERFORMANCE; ENVIRONMENT; POLLUTION; RHINITIS; ASTHMA;
D O I
10.1080/00038628.2021.1988892
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Children under 15 years spend over six hours per day in school buildings and are particularly vulnerable to the effects of poor indoor air quality (IAQ). However long-term monitoring of indoor environmental conditions is limited in Australian schools. This study evaluates IAQ in ten Australian school classrooms in the temperate settings of Victoria. Temperature, relative humidity, CO2 concentration, PM2.5 and PM10 were monitored over a period of one year. The temperature and relative humidity values in the monitored classrooms ranged between 18.7 degrees C and 23.8 degrees C and 44-63 RH%, respectively, indicating that the conditions have been mechanically controlled. The average air change (ACH) rates in the 10 school classrooms varied considerably (range: 0.7-4.83 ACH). The ventilation rates ranged from 1.6 Ls(-1) to 11.5 Ls(-1) per person with 7 out of the 10 classrooms showing ventilation rates below the recommended minimum. This study points to the need for increasing ventilation rates in classrooms.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 49 条
  • [1] ABS, 2019, Australian Demographic Statistics
  • [2] American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE), 2009, IND AIR QUAL GUID BE
  • [3] Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 Cities Study
    Annesi-Maesano, Isabella
    Hulin, Marion
    Lavaud, Francois
    Raherison, Chantal
    Kopferschmitt, Christine
    de Blay, Frederic
    Charpin, Denis Andre
    Denis, Caillaud
    [J]. THORAX, 2012, 67 (08) : 682 - 688
  • [4] [Anonymous], 2018, Standard Guide for Using Indoor Carbon Dioxide Concentrations to Evaluate Indoor Air Quality and Ventilation, DOI DOI 10.1520/D6245-18
  • [5] [Anonymous], 2020, Trends in Atmospheric Carbon Dioxide
  • [6] [Anonymous], 2006, Air Quality Guidelines: Global Update 2005: Particulate Matter, Ozone, Nitrogen Dioxide, and Sulfur Dioxide
  • [7] AS, MECH VENTILATION BUI, P125
  • [8] ASHRAE, 2016, 6212016 ANSIASHRAE, P60
  • [9] Atkinson S.E., 2012, HLTH BUILD 2012 P 10
  • [10] Baker, 2016, IND AIR 2016 14 INT