Assessment of surfactants for efficient droplet PCR in mineral oil using the pendant drop technique

被引:9
作者
Pandit, Kunal R. [1 ]
Rueger, Paul E. [1 ]
Calabrese, Richard V. [1 ]
Raghavan, Srinivasa R. [1 ,2 ]
White, Ian M. [2 ]
机构
[1] Univ Maryland, Dept Chem & Biomol Engn, College Pk, MD 20742 USA
[2] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20742 USA
关键词
Pendant drop; Droplet PCR; Brij; POLYMERASE-CHAIN-REACTION; REAL-TIME; ADSORPTION; DNA; PROTEINS; AMPLIFICATION; INTERFACES; MINUTES; TENSION; CHIP;
D O I
10.1016/j.colsurfb.2015.01.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Amplification and detection of nucleic acid sequences within integrated microsystems is routinely conducted using the technique of droplet PCR, wherein the polymerase chain reaction (PCR) is performed in microscale water-in-oil droplets (nanoliter to picoliter volumes). During droplet PCR, interactions at the interface of the droplet tend to dominate. Specifically, adsorption of the polymerase at the droplet interface leads to inefficient amplification. To reduce polymerase adsorption, surfactants such as the silicone-based ABIL EM90 have been commonly used. However, these surfactants have been selected largely through trial and error, and have been only somewhat effective. For example, when using ABIL EM90, 8 times (8x) the manufacturer prescribed concentration of polymerase was necessary for amplification. In this report, we use the pendant drop technique to measure adsorption and loss of enzyme at droplet interfaces for various surfactant-oil combinations. Dynamic interfacial tension and surface pressure measurements showed that significant polymerase adsorption occurs when using ABIL EM90. In contrast, much lower polymerase adsorption is observed when using Brij L4, a nonionic surfactant with a C-12 tail and an oxyethylene headgroup, which has not yet been reported for droplet PCR. These results correlate strongly with droplet PCR efficiency. Brij L4 enables highly efficient PCR at 2x polymerase concentration, and still enables effective PCR at 1 x polymerase concentration. Overall, this work introduces a methodology for quantitatively assessing surfactants for use with droplet microreactors, and it demonstrates the practical value of this new approach by identifying a surfactant that can dramatically improve the efficiency of droplet PCR. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:489 / 495
页数:7
相关论文
共 30 条
[1]  
Adamson AW., 1996, PHYS CHEM SURFACES
[2]   A non-gradient based algorithm for the determination of surface tension from a pendant drop: Application to low Bond number drop shapes [J].
Alvarez, Nicolas J. ;
Walker, Lynn M. ;
Anna, Shelley L. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2009, 333 (02) :557-562
[3]   Real-Time Droplet DNA Amplification with a New Tablet Platform [J].
Angione, Stephanie L. ;
Chauhan, Anuj ;
Tripathi, Anubhav .
ANALYTICAL CHEMISTRY, 2012, 84 (06) :2654-2661
[4]  
[Anonymous], 1980, HLB SYSTEM TIM SAV G
[5]  
Baret J.-C., 2012, LAB CHIP, V12, P422
[6]   On-chip, real-time, single-copy polymerase chain reaction in picoliter droplets [J].
Beer, N. Reginald ;
Hindson, Benjamin J. ;
Wheeler, Elizabeth K. ;
Hall, Sara B. ;
Rose, Klint A. ;
Kennedy, Ian M. ;
Colston, Bill W. .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8471-8475
[7]   Protein adsorption at the oil/water interface: characterization of adsorption kinetics by dynamic interfacial tension measurements [J].
Beverung, CJ ;
Radke, CJ ;
Blanch, HW .
BIOPHYSICAL CHEMISTRY, 1999, 81 (01) :59-80
[8]  
Eun H.M., 1996, Enzymology primer for recombinant DNA technology
[9]   1-Million droplet array with wide-field fluorescence imaging for digital PCR [J].
Hatch, Andrew C. ;
Fisher, Jeffrey S. ;
Tovar, Armando R. ;
Hsieh, Albert T. ;
Lin, Robert ;
Pentoney, Stephen L. ;
Yang, David L. ;
Lee, Abraham P. .
LAB ON A CHIP, 2011, 11 (22) :3838-3845
[10]  
IKAI A, 1980, J BIOCHEM-TOKYO, V88, P1895