Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility

被引:59
作者
Danilouchkine, MG [1 ]
Westenberg, JJM [1 ]
de Roos, A [1 ]
Reiber, JHC [1 ]
Lelieveldt, BPF [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, NL-2300 RC Leiden, Netherlands
关键词
left ventricle; magnetic resonance imaging; ventricular function; intra- and inter-operator variability;
D O I
10.1081/JCMR-200053578
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. To assess the intra- and inter-operator variability of the manual planning of cardiovascular magnetic resonance imaging and to evaluate the influence of these factors on the functional parameters of the left ventricle (LV). Method. The study population consisted of 10 healthy volunteers. For each subject the manual planning of the short-axis cine acquisitions was carried out twice by one operator and once by a second operator. Left ventricular volume, mass, and function were manually evaluated twice by one experienced observer, resulting in an approximation of the intra- observer variability factor. The intra- and inter-operator variation factors were estimated as the difference between the total and intra- observer variation components. Results. LV end-diastolic volume varied by 3.3% and 4.16%, and LV end-systolic volume by 5.84% and 6.23% for intra- and inter-operator studies, respectively. The variability for LV mass at end-diastole was equal to 4.23% in both studies. For the ejection fraction the variability was 3.56% and 2.97% for intra- and inter-operator studies, respectively. Comparison of reproducibility between intra- and inter-operator studies resulted in insignificant statistical differences. Bland-Altman limits of agreements revealed no systematic bias in differences between measurements with respect to their means. Reliability of the planning expressed as the angular deviation of the short-axis imaging planes amounts to 2.67 +/- 1.5 degrees and 4.99 +/- 2.17 degrees for the intra- operator and inter-operator studies, respectively. For EDV, ESV, and EF approximately 75 - 80% of the total variation can be explained by the within or between operator variation, while the same percentage is 60% for LVM. Conclusions. Our study confirms the excellent inter- and intra-operator reproducibility of the cardiovascular magnetic resonance measurements of the left ventricular volumes and mass in a group of healthy volunteers.
引用
收藏
页码:447 / 457
页数:11
相关论文
共 28 条
[1]   MEASUREMENT OF LEFT-VENTRICULAR MASS IN HYPERTROPHIC CARDIOMYOPATHY USING MRI - COMPARISON WITH ECHOCARDIOGRAPHY [J].
ALLISON, JD ;
FLICKINGER, FW ;
WRIGHT, JC ;
FALLS, DG ;
PRISANT, LM ;
VONDOHLEN, TW ;
FRANK, MJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :329-334
[2]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
Bogaert J G, 1995, MAGMA, V3, P5, DOI 10.1007/BF02426395
[5]   MEASUREMENT OF CANINE LEFT-VENTRICULAR MASS BY USING MR IMAGING [J].
CAPUTO, GR ;
TSCHOLAKOFF, D ;
SECHTEM, U ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :33-38
[6]   MAGNETIC-RESONANCE IMAGING OF THE HEART USING IMAGE PLANES ORIENTED TO CARDIAC AXES - EXPERIENCE WITH 100 CASES [J].
DINSMORE, RE ;
WISMER, GL ;
MILLER, SW ;
THOMPSON, R ;
JOHNSTON, DL ;
LIU, P ;
OKADA, RD ;
SAINI, S ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (06) :1177-1183
[7]   MAGNETIC-RESONANCE IMAGING OF THE HEART - POSITIONING AND GRADIENT ANGLE SELECTION FOR OPTIMAL IMAGING PLANES [J].
DINSMORE, RE ;
WISMER, GL ;
LEVINE, RA ;
OKADA, RD ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1135-1142
[8]   Efficient model-based quantification of left ventricular function in 3-D echocardiography [J].
Gérard, O ;
Billon, AC ;
Rouet, JM ;
Jacob, M ;
Fradkin, M ;
Allouche, C .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1059-1068
[9]   REPRODUCIBILITY OF LEFT-VENTRICULAR VOLUMES BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
GORDON, EP ;
SCHNITTGER, I ;
FITZGERALD, PJ ;
WILLIAMS, P ;
POPP, RL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (03) :506-513
[10]   Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy [J].
Grothues, F ;
Smith, GC ;
Moon, JCC ;
Bellenger, NG ;
Collins, P ;
Klein, HU ;
Pennell, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (01) :29-34