Mathematical model in left ventricle segmentation

被引:5
作者
Bugdol, Monika N. [1 ]
Pietka, Ewa [1 ]
机构
[1] Silesian Tech Univ, Fac Biomed Engn, Gliwice, Poland
关键词
Cardiac MRI; Left ventricle; Automatic segmentation; Parametric model; Model-based segmentation; CARDIAC MR; AUTOMATED SEGMENTATION; EDGE-DETECTION; IMAGES; TRACKING; SHAPE; CT;
D O I
10.1016/j.compbiomed.2014.12.009
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper a parametric model of the left ventricle is presented. Its task is to estimate the myocardium shape on those slices, on which the segmentation algorithm has outlined the structure incorrectly. The aim of using the model on improperly segmented slices is to improve the accuracy of computing cardiac hemodynamic parameters and the heart mass. The proposed model works with any segmentation algorithm. The usefulness of the model is the largest while determining the myocardium at end-systole and calculating the heart mass. In case of the segmentation algorithm applied in this study, the error decreased from clinically unacceptable to acceptable after using the presented model. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:187 / 200
页数:14
相关论文
共 42 条
  • [1] Boykov Y, 2000, LECT NOTES COMPUT SC, V1935, P276
  • [2] Graph cuts and efficient N-D image segmentation
    Boykov, Yuri
    Funka-Lea, Gareth
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 2006, 70 (02) : 109 - 131
  • [3] Boykov YY, 2001, EIGHTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOL I, PROCEEDINGS, P105, DOI 10.1109/ICCV.2001.937505
  • [4] Bugdol M.N., 2012, INT J COMPUT ASSIST, V7, P540
  • [5] Bugdol M, 2012, COMPUT CARDIOL CONF, V39, P561
  • [6] Chaudhuri B.B., 2009, IEEE REG 10 C TENCON, P1
  • [7] RECOVERY OF THE 3-D SHAPE OF THE LEFT-VENTRICLE FROM ECHOCARDIOGRAPHIC IMAGES
    COPPINI, G
    POLI, R
    VALLI, G
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (02) : 301 - 317
  • [8] Segmentation of 4D cardiac MRI: Automated method based on spatio-temporal watershed cuts
    Cousty, J.
    Najman, L.
    Couprie, M.
    Clement-Guinaudeau, S.
    Goissen, T.
    Garot, J.
    [J]. IMAGE AND VISION COMPUTING, 2010, 28 (08) : 1229 - 1243
  • [9] AUTOMATED MYOCARDIAL EDGE-DETECTION ON MR-IMAGES - ACCURACY IN CONSECUTIVE SUBJECTS
    FLEAGLE, SR
    THEDENS, DR
    STANFORD, W
    THOMPSON, BH
    WESTON, JM
    PATEL, PP
    SKORTON, DJ
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 738 - 741
  • [10] IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES
    FOO, TKF
    BERNSTEIN, MA
    AISEN, AM
    HERNANDEZ, RJ
    COLLICK, BD
    BERNSTEIN, T
    [J]. RADIOLOGY, 1995, 195 (02) : 471 - 478